Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
2.
Rhinology ; 62(3): 330-341, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38189480

RESUMO

BACKGROUND: In this study, we identified key discrete clinical and technical factors that may correlate with primary reconstructive success in endoscopic skull base surgery (ESBS). METHODS: ESBS cases with intraoperative cerebrospinal fluid (CSF) leaks at four tertiary academic rhinology programs were retrospectively reviewed. Logistic regression identified factors associated with surgical outcomes by defect subsite (anterior cranial fossa [ACF], suprasellar [SS], purely sellar, posterior cranial fossa [PCF]). RESULTS: Of 706 patients (50.4% female), 61.9% had pituitary adenomas, 73.4% had sellar or SS defects, and 20.5% had high-flow intraoperative CSF leaks. The postoperative CSF leak rate was 7.8%. Larger defect size predicted ACF postoperative leaks; use of rigid reconstruction and older age protected against sellar postoperative leaks; and use of dural sealants compared to fibrin glue protected against PCF postoperative leaks. SS postoperative leaks occurred less frequently with the use of dural onlay. Body-mass index, intraoperative CSF leak flow rate, and the use of lumbar drain were not significantly associated with postoperative CSF leak. Meningitis was associated with larger tumors in ACF defects, nondissolvable nasal packing in SS defects, and high-flow intraoperative leaks in PCF defects. Sinus infections were more common in sellar defects with synthetic grafts and nondissolvable nasal packing. CONCLUSIONS: Depending on defect subsite, reconstructive success following ESBS may be influenced by factors, such as age, defect size, and the use of rigid reconstruction, dural onlay, and tissue sealants.


Assuntos
Vazamento de Líquido Cefalorraquidiano , Endoscopia , Procedimentos de Cirurgia Plástica , Base do Crânio , Humanos , Feminino , Masculino , Base do Crânio/cirurgia , Vazamento de Líquido Cefalorraquidiano/etiologia , Vazamento de Líquido Cefalorraquidiano/prevenção & controle , Vazamento de Líquido Cefalorraquidiano/epidemiologia , Estudos Retrospectivos , Pessoa de Meia-Idade , Endoscopia/métodos , Procedimentos de Cirurgia Plástica/métodos , Adulto , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Idoso , Neoplasias Hipofisárias/cirurgia , Neoplasias da Base do Crânio/cirurgia , Rinorreia de Líquido Cefalorraquidiano/prevenção & controle , Rinorreia de Líquido Cefalorraquidiano/cirurgia , Rinorreia de Líquido Cefalorraquidiano/etiologia
3.
Rhinology ; 61(4): 297-311, 2023 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-37219052

RESUMO

INTRODUCTION: Silent sinus syndrome (SSS) is a rare disorder of the maxillary sinus, which may present with orbital symptoms. Most reports of silent sinus syndrome are limited to small series or case reports. This systematic review comprehensively characterizes the various clinical presentations, management, treatment, and outcomes in patients with SSS. METHODS: A systematic literature search of the PubMed, Cochrane, Web of Science, and Scopus databases. Inclusion criteria were studies describing the presentation, management, or treatment of SSS or chronic maxillary atelectasis. RESULTS: One hundred fifty-three articles were included in the final review (n=558 patients). Mean age at diagnosis was 38.8 +- 14.1 years, with a relatively even distribution among sexes. Enophthalmos and/or hypoglobus were the most frequent symptoms, along with diplopia, headache, or facial pressure/pain. Most patients (87%) underwent functional endoscopic sinus surgery (FESS), and 23.5% received orbital floor reconstruction. Post-treatment, patients had significant reductions in enophthalmos (2.67 +- 1.39 vs. 0.33 +- 0.75 mm) and hypoglobus (2.22 +- 1.43 vs. 0.23 +- 0.62 mm). Most patients (83.2%) achieved partial or total resolution of clinical symptoms. CONCLUSIONS: SSS has a variable clinical presentation, with enophthalmos and hypoglobus being most common. FESS with or without orbital reconstruction are effective treatments to address the underlying pathology and structural deficits.


Assuntos
Enoftalmia , Doenças dos Seios Paranasais , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Enoftalmia/diagnóstico , Enoftalmia/etiologia , Enoftalmia/terapia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Síndrome , Doenças dos Seios Paranasais/diagnóstico , Doenças dos Seios Paranasais/cirurgia , Seio Maxilar/cirurgia
4.
AJNR Am J Neuroradiol ; 44(2): 171-175, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36657948

RESUMO

BACKGROUND AND PURPOSE: There is active research involving the radiographic appearance of the skull base following reconstruction. The purpose of this study was to describe the radiographic appearance of the vascularized pedicle nasoseptal flap after endoscopic skull base surgery across time. MATERIALS AND METHODS: We performed chart and imaging review of all patients with intraoperative nasoseptal flap placement during endoscopic skull base surgery at a tertiary academic skull base surgery program between July 2018 and March 2021. All patients underwent immediate and delayed (>3 months) postoperative MR imaging. Primary outcome variables included flap and pedicle enhancement, flap thickness, and flap adherence to the skull base. RESULTS: Sixty-eight patients were included. Flap (P = .003) enhancement significantly increased with time. Mean nasoseptal flap thickness on immediate and delayed postoperative scans was 3.8 and 3.9 mm, respectively (P = .181). The nasoseptal flap adhered entirely to the skull base in 37 (54.4%) and 67 (98.5%) patients on immediate and delayed imaging, respectively (P < .001). CONCLUSIONS: Our findings demonstrate heterogeneity of the nasoseptal flap appearance after skull base reconstruction. While it is important for surgeons and radiologists to evaluate variations in flap appearance, the absence of enhancement and lack of adherence to the skull base on immediate postoperative imaging do not appear to predict reconstructive success and healing, with many flaps "self-adjusting" with time.


Assuntos
Procedimentos de Cirurgia Plástica , Humanos , Septo Nasal/diagnóstico por imagem , Septo Nasal/cirurgia , Estudos Retrospectivos , Retalhos Cirúrgicos/cirurgia , Base do Crânio/diagnóstico por imagem , Base do Crânio/cirurgia , Endoscopia/métodos
6.
Biomed Microdevices ; 21(1): 10, 2019 01 10.
Artigo em Inglês | MEDLINE | ID: mdl-30631976

RESUMO

The number of procedures performed with robotic surgery may exceed one million globally in 2018. The continual lack of haptic feedback, however, forces surgeons to rely on visual cues in order to avoid breaking sutures due to excessive applied force. To mitigate this problem, the authors developed and validated a novel grasper-integrated system with biaxial shear sensing and haptic feedback to warn the operator prior to anticipated suture breakage. Furthermore, the design enables facile suture manipulation without a degradation in efficacy, as determined via measured tightness of resulting suture knots. Biaxial shear sensors were integrated with a da Vinci robotic surgical system. Novice subjects (n = 17) were instructed to tighten 10 knots, five times with the Haptic Feedback System (HFS) enabled, five times with the system disabled. Seven suture failures occurred in trials with HFS enabled while seventeen occurred in trials without feedback. The biaxial shear sensing system reduced the incidence of suture failure by 59% (p = 0.0371). It also resulted in 25% lower average applied force in comparison to trials without feedback (p = 0.00034), which is relevant because average force was observed to play a role in suture breakage (p = 0.03925). An observed 55% decrease in standard deviation of knot quality when using the HFS also indicates an improvement in consistency when using the feedback system. These results suggest this system may improve outcomes related to knot tying tasks in robotic surgery and reduce instances of suture failure while not degrading the quality of knots produced.


Assuntos
Teste de Materiais , Procedimentos Cirúrgicos Robóticos/instrumentação , Suturas , Resistência à Tração , Humanos , Procedimentos Cirúrgicos Robóticos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...