Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Paediatr Int Child Health ; 40(1): 16-24, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31142230

RESUMO

Background: In Nigeria, neonatal jaundice is commonly treated by overhead phototherapy with neonates lying supine, often with effective exposure of less than one half of the body surface. Total body exposure in phototherapy has been in use for less than 2 years in Nigeria, but is available in only five neonatal centres.Aim: To compare the effectiveness of total body exposure (TBPE) with the conventional partial exposure (COPT) for treatment of hyperbilirubinaemia.Methods: Eleven datasets from 10 neonatal units across Nigeria were retrieved. They included neonates with severe hyperbilirubinaemia treated with TBPE using the Firefly® device (MTTS Asia) as a test group. The remainder of the patients, the controls, were treated with COPT. Any requirement for exchange blood transfusion (EBT) in either group was documented. Total serum bilirubin (TSB) >213.8 µmol/L (12.5 mg/dL) was treated as severe hyperbilirubinaemia. The efficiency of the intervention was determined according to the time taken for a severe case to be downgraded to mild at ≤213.8 µmol/L.Results: A total of 486 patients were studied, 343 controls and 143 cases. Mean (SD) postnatal age was 6 days (0.7) for cases and 5 (0.9) for controls, for gestational age (GA) in completed weeks was 36 (0.5) for cases and 37 (0.7) for controls and for birthweight was 2.7 kg (0.25) for cases and 2.7 (0.22) for controls. Mean (SD) pre-intervention TSB was 299.3 (35.7) µmol/L for cases and 327.3 (13.9) for controls. Severity downgrade day was Day 2 (0.4) for cases and Day 5 (1.1) for controls. Overall relative EBT rate was 6% for cases and 55% for controls (p= 0.0001), and early preterm relative EBT rate was 0% for cases and 68% for controls (p < 0.01).Conclusion: TBPE was quicker and safer for reduction of hyperbilirubinaemia and patients rarely required EBT. TBPE is recommended for rapid reduction of serum bilirubin levels and the reduction of treatment costs, morbidity and mortality in low- and middle-income countries.Abbreviations: EBT, exchange blood transfusion; TBPE, total body exposure technique; COPT, conventional partial exposure; TSB, total serum bilirubin; SB, serum bilirubin; NNJ, neonatal jaundice; SCNU, special care neonatal unit; LMIC, low- and middle-income countries; HIC, high-income countries; LED, light-emitting diode.


Assuntos
Icterícia Neonatal/terapia , Fototerapia/métodos , Humanos , Recém-Nascido , Nigéria , Estudos Retrospectivos , Resultado do Tratamento
2.
Paediatr Int Child Health ; 39(3): 184-192, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30957682

RESUMO

Background: The bubble continuous positive airway pressure (bCPAP) technique is widely applied in neonatal respiratory support. Commercial bCPAP brands are expensive in Nigeria and this has driven Nigerian paediatricians to use potentially risky improvised devices (IbCPAP). Aim: This study aimed to design, produce and trial an appropriate low-cost bCPAP machine which is functionally effective and safe. Methods: Questionnaires were distributed to assess the need for a new bCPAP design for use in Nigeria, leading to the development of a new system (politeCPAP) which was functionally and clinically validated in three Nigerian hospitals. Six months of clinical data on the new device of sufficient comparative quality were generated from one of the hospitals and compared with control data on the IbCPAP. The hospitals (n = 3) submitted data on 71 patients on IbCPAP or politeCPAP; 14 were disqualified on the basis of the elimination criteria. The infants were classified into two birthweight categories: <1000 g (extremely low birthweight, ELBW, n = 15) and 1000 g (n = 42). Results: Six ELBW neonates on politeCPAP survived; there were no ELBW survivors in the IbCPAP group (n = 9). The IbCPAP device delivered an average 90% O2-gas ratio (FiO2) whereas the politeCPAP required only 47%. Many heavier neonates in the IbCPAP group survived (23 of 26); however, supplementary warming was required for all of them whereas none of the politeCPAP infants required warming. The politeCPAP costs around US$2000 whereas standard commercial CPAP brands in Nigeria range from US$5000 to US$18,000. High oxygen requirement and iatrogenic hypothermia were serious adverse features of IbCPAP. Conclusions: The study has narrowed the gap between relatively low-cost, risky devices (e.g. IbCPAP) and high-cost commercial machines. The politeCPAP is a feasible alternative to the IbCPAP in cost-constrained settings. Abbreviations: bCPAP: bubble continuous positive airway pressure; CPAP: continuous positive airway pressure; ELBW: extremely low birthweight; FiO2: ratio of oxygen content in gas flow (%); IbCPAP: improvised bubble continuous positive airway pressure device; LBW: low birthweight; NNU: neonatal unit; PEEP: positive end expiratory pressure; politeCPAP: the newly developed commercial bCPAP machine; RDS: respiratory distress syndrome; SpO2, oxygen saturation level (%).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Equipamentos e Provisões/economia , Síndrome do Desconforto Respiratório/terapia , Pressão Positiva Contínua nas Vias Aéreas/economia , Custos de Cuidados de Saúde , Humanos , Lactente , Recém-Nascido , Nigéria , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...