Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Bioeng Biotechnol ; 12: 1410053, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38994124

RESUMO

Aims: The ovine stifle is an established model for evaluation of knee treatments, such as meniscus replacement. This study introduces a novel ovine gait simulator for pre-testing of surgical treatments prior to in vivo animal trials. Furthermore, we describe a pilot study that assessed gait kinematics and contact pressures of native ovine stifle joints and those implanted with a novel fiber-matrix reinforced polyvinyl alcohol-polyethylene glycol (PVA-PEG) hydrogel meniscus to illustrate the efficacy of the simulator. Methods: The gait simulator controlled femoral flexion-extension and applied a 980N axial contact force to the distal tibia, whose movement was guided by the natural ligaments. Five right ovine stifle joints were implanted with a PVA-PEG total medial meniscus replacement, fixed to the tibia via transosseous tunnels and interference screws. Six intact and five implanted right ovine stifle joints were tested for 500 k gait cycles at 1.55 Hz. Implanted stifle joint contact pressures and kinematics in the simulator were compared to the intact group. Contact pressures were measured at 55° flexion using pressure sensitive film inserted sub-meniscally. 3D kinematics were measured optically across two 30-s captures. Results: Peak contact pressures in intact stifles were 3.6 ± 1.0 MPa and 6.0 ± 2.1 MPa in the medial and lateral condyles (p < 0.05) and did not differ significantly from previous studies (p > 0.4). Medial peak implanted pressures were 4.3 ± 2.2 MPa (p > 0.4 versus intact), while lateral peak pressures (9.4 ± 0.8 MPa) were raised post medial compartment implantation (p < 0.01). The range of motion for intact joints was flexion/extension 37° ± 1°, varus/valgus 1° ± 1°, external/internal rotation 5° ± 3°, lateral/medial translation 2 ± 1 mm, anterior/posterior translation 3 ± 1 mm and distraction/compression 1 ± 1 mm. Ovine joint kinematics in the simulator did not differ significantly from published in vivo data for the intact group, and the intact and implanted groups were comparable (p > 0.01), except for in distraction-compression (p < 0.01). Conclusion: These findings show correspondence of the ovine simulator kinematics with in vivo gait parameters. The efficacy of the simulator to evaluate novel treatments was demonstrated by implanting a PVA-PEG hydrogel medial meniscal replacement, which restored the medial peak contact pressures but not lateral. This novel simulator may enable future work on the development of surgical procedures, derisking subsequent work in live animals.

2.
Comput Methods Biomech Biomed Engin ; 17(14): 1553-71, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23452160

RESUMO

The article presents advanced computer simulations aimed at the accurate modelling of human tibio-femoral joints (TFJs) in terms of anatomy, physiological loading and constitutive behaviour of the tissues. The main objective of this research is to demonstrate the implications that the implementation of different articular cartilage models have on the prediction of the joint response. Several biphasic material constitutive laws are tested using a finite element package and compared to the monophasic linear elastic description, often still used to predict the instantaneous response of the cartilage in 3D knee models. Thus, the importance of adequately capturing the contribution of the interstitial fluid support is proved using a simplified 3D model; subsequently, a biphasic poroviscoelastic non-linear constitutive law is implemented to study the response of a patient-specific TFJ subjected to simplified walking cycles. The time evolution of stresses, pore pressure, contact areas and joint displacements is captured and compared with existing meniscectomised knee models. Contact pressures and areas obtained using the developed numerical simulations are in agreement with the existing experimental evidence for meniscectomised human knee joints. The results are then used to predict the most likely site for the origin of mechanical damage, i.e. the medial cartilage surface for the specific case analysed in the present contribution. Finally, future research directions are suggested.


Assuntos
Cartilagem Articular/fisiologia , Articulação do Joelho/fisiologia , Articulação do Joelho/cirurgia , Modelos Biológicos , Fenômenos Biomecânicos , Simulação por Computador , Fêmur , Análise de Elementos Finitos , Humanos , Articulação do Joelho/anatomia & histologia , Pressão , Tíbia , Caminhada , Suporte de Carga
3.
Tissue Eng Part A ; 19(19-20): 2300-10, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23688110

RESUMO

Articular cartilage provides a low-friction, wear-resistant surface for diarthrodial joints. Due to overloading and overuse, articular cartilage is known to undergo significant wear and degeneration potentially resulting in osteoarthritis (OA). Regenerative medicine strategies offer a promising solution for the treatment of articular cartilage defects and potentially localized early OA. Such strategies rely on the development of materials to restore some aspects of cartilage. In this study, microfibrous poly(ɛ-caprolactone) scaffolds of varying fiber orientations (random and aligned) were cultured with bovine chondrocytes for 4 weeks in vitro, and the mechanical and frictional properties were evaluated. Mechanical properties were quantified using unconfined compression and tensile testing techniques. Frictional properties were investigated at physiological compressive strains occurring in native articular cartilage. Scaffolds were sheared along the fiber direction, perpendicular to the fiber direction and in random orientation. The evolution of damage as a result of shear was evaluated via white light interferometry and scanning electron microscopy. As expected, the fiber orientation strongly affected the tensile properties as well as the compressive modulus of the scaffolds. Fiber orientation did not significantly affect the equilibrium frictional coefficient, but it was, however, a key factor in dictating the evolution of surface damage on the surface. Scaffolds shear tested perpendicular to the fiber orientation displayed the highest surface damage. Our results suggest that the fiber orientation of the scaffold implanted in the joint could strongly affect its resistance to damage due to shear. Scaffold fiber orientation should thus be carefully considered when using microfibrous scaffolds.


Assuntos
Cartilagem Articular/citologia , Condrócitos/citologia , Alicerces Teciduais/química , Animais , Bovinos , Células Cultivadas , Força Compressiva , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...