Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Tex Heart Inst J ; 49(5)2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36269883

RESUMO

BACKGROUND: Ablation of atrial tachyarrhythmia in adults with congenital heart disease (ACHD) is challenging because of complex anatomy and high scar burden. We proposed that the addition of high-density mapping with the PentaRay® (Biosense Webster, Inc) mapping catheter (EAM+P) to 3-dimensional electroanatomic mapping (EAM) allows for rapid acquisition of high-resolution maps and shorter procedure times. METHODS: In this single-center, retrospective cohort study of patients with ACHD who underwent atrial arrhythmia ablation, patients were divided those who underwent ablation with EAM and those who underwent ablation with EAM+P. RESULTS: Fifteen ablations were performed in 13 patients using standard EAM, and 11 ablations were performed in 10 patients using EAM+P. There was no difference in mean age or complexity of congenital heart disease. The procedure duration was 1.5 times longer in the EAM than in the EAM+P group (P = .015). The dose area product was 12 times higher in the EAM than in the EAM+P group (P = .001). A higher number of venous access sites were used for EAM cases than for EAM+P cases (P = .008). Acute success rates of ablation and recurrence rates at 1 year were similar in the 2 groups. There were no procedure-related complications in either group. CONCLUSION: This is the first study to evaluate the use of the PentaRay® high-density mapping catheter for ablation of atrial tachyarrhythmia in patients with ACHD. The use of the PentaRay® high-density mapping catheter results in shorter procedure time, decreased radiation exposure, and fewer venous access sites.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Cardiopatias Congênitas , Adulto , Humanos , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Taquicardia , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/cirurgia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/cirurgia , Catéteres , Fibrilação Atrial/cirurgia
2.
Europace ; 18(7): 1016-22, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26705566

RESUMO

AIMS: Patients with D-loop transposition of the great arteries (D-TGA) status post intra-atrial baffling are at an increased risk for sudden cardiac arrest. The benefit of primary implantable cardioverter-defibrillator (ICD) implantation in these patients is questionable due to high burden of adverse events. We aimed to evaluate the incidence and causes of all types of device shocks, as well as of device-related complications among patients with D-TGA implanted with ICDs for primary prevention. METHODS AND RESULTS: Retrospective analysis of all patients with D-TGA who underwent atrial switch procedure and ICD implantation for primary prevention. Eighteen patients (83% males) were identified. Average age at atrial switch was 2.5 years (range 0.1-17) and at ICD implantation 26 years (15-41). During a median follow-up of 4 years, 10 patients (55%) received shocks for non-ventricular arrhythmic events, whereas 1 patient was shocked for ventricular tachycardia, for an annual rate of shock delivery of 7.1%. The most common cause for shock delivery was the occurrence of atrial arrhythmias, mostly in the form of atrial flutter. Elevated systemic ventricular end-diastolic pressures were found to be associated with an increased risk for inappropriate shocks. Five patients (28%) required lead extraction and three required generator change due to device recalls during follow-up. CONCLUSION: Atrial arrhythmias were the most common cause for ICD shocks in a primary prevention population, while ventricular tachycardia was infrequent. The association between elevated end-diastolic pressures and the occurrence of arrhythmias demonstrates the close mechano-electrical relationship in D-TGA and may be an important predictor of arrhythmic events.


Assuntos
Flutter Atrial/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/epidemiologia , Transposição dos Grandes Vasos/complicações , Adolescente , Adulto , Feminino , Átrios do Coração/fisiopatologia , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Prevenção Primária , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Transposição dos Grandes Vasos/cirurgia , Adulto Jovem
3.
Acta Cardiol ; 66(4): 527-30, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21894813

RESUMO

Cardiac resynchronization therapy is increasingly being used in the paediatric population as a tool for managing patients with heart failure. Various non-invasive parameters have been used to optimize the settings on the biventricular pacemaker. We describe implantation of a biventricular pacemaker in a nineteen-month-old child because of intractable heart failure. By analysing a 17-segment model using strain analysis of the left ventricle, we were able to place the left ventricular lead at the latest activated segment. Furthermore, we were able to minimize the dyssynchrony of the left ventricle when evaluating a range of pacemaker settings.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Insuficiência Cardíaca/terapia , Débito Cardíaco , Técnicas Eletrofisiológicas Cardíacas , Insuficiência Cardíaca/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Lactente , Ultrassonografia
4.
Congenit Heart Dis ; 4(6): 448-53, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19925538

RESUMO

INTRODUCTION: Pediatric patients with complete heart block (CHB) often require pacemaker therapy. Adult studies have shown chronic right ventricular pacemaker therapy may be associated with decreased echocardiographic parameters and increased brain natriuretic peptide (BNP) values. The goal of this study was to determine if there are echocardiographic or BNP changes in a pediatric population that is chronically paced. METHODS: Patients were recruited if they had CHB and had a pacemaker. Patients were excluded if they had congenital structural heart disease. Standard two-dimensional echocardiograms, including tissue Doppler imaging (TDI), were performed. BNP values were obtained. Nonparametric Spearman's rank correlation was used for analysis. Rho < or = 0.05 was considered significant. RESULTS: Eighteen patients (16.4 +/- 7.3 years) with CHB were studied. Age at implant was 8.6 +/- 6.6 years and length of pacing was 7.8 +/- 6.6 years. Pacing mode was VDD, DDD, DDDR, or VVIR. All patients were ventricularly paced >95% of the time. Ejection fraction was 58.5 +/- 7.5%. All BNP values were <40 pg/mL. There was no correlation between ejection fraction or BNP level with the length of pacing years. Pacing years significantly correlated with mitral and tricuspid E/A ratios (rho =-0.56, -0.56, respectively). Pacing years also correlated with right ventricular and interventricular TDI a wave (rho = 0.61 and 0.68, respectively). Furthermore, pacing years correlated with right ventricular TDI e/a ratio (rho =-0.58). CONCLUSIONS: Ejection fraction and BNP levels were not sensitive parameters in evaluating pediatric patients who are chronically paced. Subtle diastolic changes, especially of the right ventricle, were detected by TDI.


Assuntos
Ecocardiografia Doppler , Bloqueio Cardíaco/diagnóstico por imagem , Bloqueio Cardíaco/terapia , Marca-Passo Artificial , Disfunção Ventricular Direita/diagnóstico por imagem , Adolescente , Criança , Doença Crônica , Diástole , Eletrocardiografia , Feminino , Humanos , Masculino , Peptídeo Natriurético Encefálico/sangue , Volume Sistólico , Sístole , Função Ventricular Esquerda , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...