Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Am Acad Orthop Surg ; 32(7): e331-e345, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417145

RESUMO

INTRODUCTION: External fixation is a critical component of orthopaedic fracture management and is used for various conditions, including trauma and pediatric orthopaedics. However, the availability and high cost of external fixation devices are a concern, especially in rural and developing countries. 3D printing technology has shown promise in reducing manufacturing costs and improving accessibility to external fixation devices. The purpose of this study was to evaluate the mechanical properties of a fully 3D-printed desktop external fixation device and compare the results with the mechanical properties of commonly used, clinically available external fixators. METHODS: A fully 3D printable external fixator was designed and printed in polylactic acid at two infill densities, 20% and 100%. The mechanical properties of the 3D-printed external fixators and several commercially available fixators were tested according to applicable sections of the American Society for Testing and Materials F1541 standard protocol in axial, medial-lateral, and anterior-posterior orientations. The primary outcomes measured included failure load, safe load, rigidity, and yield load. The mean differences between experimental and control groups were calculated using one-way analysis of variance and Tukey tests. RESULTS: The 20% infill 3D-printed construct showed poor performance compared with commercially available external fixators in all testing conditions and across most variables. The 100% infill 3D-printed construct was comparable with or superior to all commercially available devices in most testing conditions. The cost for printing a single 3D-printed 100% infill external fixator was $14.49 (United States Dollar). DISCUSSION: This study demonstrates that a low-cost desktop 3D printer can create an entirely 3D-printed external fixator that resists clinically relevant forces similar to medical-grade industry-standard external fixators. Therefore, there is potential for customizable and low-cost external fixators to be manufactured with desktop 3D printing for use in remote areas and other resource-constrained environments for fracture care.


Assuntos
Fraturas Ósseas , Ortopedia , Criança , Humanos , Estados Unidos , Fixadores Externos , Próteses e Implantes , Impressão Tridimensional
4.
S D Med ; 76(8): 363-366, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37734080

RESUMO

Achilles tendon rupture is a common injury. It most often occurs in middle aged men who participate in recreational sports. The injury classically presents with a loud popping noise and immediate pain and weakness of the lower extremity during actions such as jumping or running. The diagnosis is made clinically, but an MRI is often obtained for confirmation of rupture and to aid in surgical planning. Treatment is either operative, with open or minimally invasive approaches, or non-operative, with functional bracing or plaster casting. Surgical treatment was preferred for much of the 20th century, but non-operative treatment has gained significant favor in the past 15 years as new evidence has demonstrated similar long-term outcomes to surgery. Neither treatment option is currently considered superior to the other in all cases. Surgery is associated with a risk for surgical complications and is, therefore, often a poor option for the elderly and those with significant comorbidities. Non-operative management is associated with an increased risk for re-injury which is often undesirable for young and highly active patients. Ultimately, the goals and priorities of each individual patient should guide the decision of which treatment option to pursue.


Assuntos
Tendão do Calcâneo , Corrida , Traumatismos dos Tendões , Idoso , Masculino , Pessoa de Meia-Idade , Humanos , Traumatismos dos Tendões/diagnóstico , Traumatismos dos Tendões/terapia , Extremidade Inferior , Dor
5.
JSES Rev Rep Tech ; 3(1): 60-66, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37588075

RESUMO

Background: Pitchers are prone to upper extremity injury due to repetitive high joint loads. Clinical measures of shoulder strength and range of motion (ROM) have shown links to injury risk in pitchers, however, these factors have rarely been studied in relation to throwing joint loads. The purpose of this study was to identify which clinical ROM and isokinetic strength variables were related to peak shoulder and elbow joint torques in collegiate pitchers. Methods: Thirty-three healthy collegiate pitchers participated in this study. Fastball velocity, shoulder concentric and eccentric strength, and passive shoulder ROM variables were analyzed using a Lasso regression to determine what factors influenced shoulder internal rotation torque and elbow varus torque. Results: Fastball velocity was selected by the Lasso as indicator of increased shoulder and elbow torque. Passive shoulder external rotation ROM was also selected as an important factor in joint loading with increased shoulder external rotation ROM being related to lower joint loads. The bilateral ratio of shoulder internal rotator concentric strength was related to peak shoulder and elbow torques with an increase in the bilateral ratio of shoulder strength leading to reduced joint torques. Increases in the eccentric external rotator to concentric internal rotator strength (functional ratio) of the dominant arm and increases in dominant arm eccentric internal rotator strength were both related to increases in each joint torque. Conclusion: Results from the study indicate that pitch speed, passive shoulder external rotation ROM, and the isokinetic shoulder strength profile including internal rotator strength and functional strength ratio of pitchers are related to joint loading during the pitch and may be important to monitor in relation to injury risk and/or during rehabilitation. These results provide insight into the role that both shoulder ROM and rotator cuff strength play in the dynamic stabilization of the elbow and shoulder during pitching.

6.
Arthrosc Tech ; 12(5): e683-e686, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-37323781

RESUMO

The goal of acetabular labral repair is to restore stable contact between the labrum and acetabular rim while maintaining the anatomic suction seal. One of the challenges of labral repair is achieving proper in-round repair, so that the labrum contacts the femoral head in the native position. This technique article presents a repair method that allows for enhanced inversion of the labrum to assist with anatomic repair. Our modified toggle suture technique utilizes an anchor-first method and has various distinct technical advantages. We present an efficient and vendor-agnostic technique that allows for straight or curved guides. Similarly, the anchors may be all-suture or hard-anchor designs that accommodate suture sliding. This technique also utilizes a self-retaining hand-tied knot construct to facilitate preventing knots from migrating toward the femoral head or joint space.

7.
3D Print Med ; 9(1): 15, 2023 Jun 07.
Artigo em Inglês | MEDLINE | ID: mdl-37284965

RESUMO

BACKGROUND: External fixators are complex, expensive orthopaedic devices used to stabilize high-energy and complex fractures of the extremities. Although the technology has advanced dramatically over the last several decades, the mechanical goals for fracture stabilization of these devices have remained unchanged. Three-dimensional (3D) printing technology has the potential to advance the practice and access to external fixation devices in orthopaedics. This publication aims to systematically review and synthesize the current literature on 3D printed external fixation devices for managing orthopaedic trauma fractures. METHODS: The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) protocols were followed for this manuscript with minor exceptions. PubMed, Embase, Cochrane Review, Google Scholar, and Scopus online databases were systematically searched. Two independent reviewers screened the search results based on predetermined inclusion and exclusion criteria related to 3D printing and external fixation of fractures. RESULTS: Nine studies met the inclusion criteria. These included one mechanical testing study, two computational simulation studies, three feasibility studies, and three clinical case studies. Fixator designs and materials varied significantly between authors. Mechanical testing revealed similar strength to traditional metal external fixators. Across all clinical studies, five patients underwent definitive treatment with 3D printed external fixators. They all had satisfactory reduction and healing with no reported complications. CONCLUSIONS: The current literature on this topic is heterogeneous, with highly variable external fixator designs and testing techniques. A small and limited number of studies in the scientific literature have analyzed the use of 3D printing in this area of orthopaedic surgery. 3D printed external fixation design advancements have yielded promising results in several small clinical case studies. However, additional studies on a larger scale with standardized testing and reporting techniques are needed.

8.
J Biomech ; 149: 111462, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36812798

RESUMO

Student engagement in science, technology, engineering, and math (STEM) through informal outreach events is critical to the current educational pipeline. National Biomechanics Day (NBD) is a STEM outreach event that is an international celebration of the science of biomechanics with the goal of introducing high school students to the field. While NBD has experienced global success and substantial growth in recent years, it is an equally rewarding and challenging endeavor to host an NBD event. In this paper, we provide recommendations and mechanisms for biomechanics professionals to support their success in hosting biomechanics outreach events. Although these guidelines are framed around hosting an NBD event, the underlying principles can apply to hosting any STEM outreach event.


Assuntos
Ciência , Humanos , Fenômenos Biomecânicos , Ciência/educação , Engenharia , Tecnologia , Motivação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...