1.
Diseases ; 11(2)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37092437

RESUMO

The transmission of healthcare-associated infections (HCAIs) in healthcare settings is a serious challenge in the medical fraternity. Medical devices, such as stethoscopes used by healthcare workers (HCWs), are likely to harbor a considerable number of pathogenic microbes, which may result in the transmission of HCAIs. This study sought to investigate bacterial contamination of stethoscopes used by HCWs at Bharatpur Hospital, Nepal. During the study period of 3 months from December 2019 to February 2020, a total of 87 stethoscopes were examined; bacterial pathogens were isolated and identified by culture and biochemical tests, and their susceptibilities against different antibiotics were determined using standard protocols of the Clinical and Laboratory Standards Institute (CLSI). The disc diffusion method was used primarily to screen for extended-spectrum beta-lactamase (ESBL)- and metallo-beta-lactamase (MBL)-producing isolates, followed by their confirmation using cephalosporin/clavulanate combination discs and the disc potentiation methods, respectively. In addition, molecular detection of blaCTX-M and blaVIM genes was performed using conventional polymerase chain reaction (PCR). Of the 87 stethoscopes examined, more than a quarter (28.7%) were colonized with different pathogenic bacteria. Bacterial contamination of stethoscopes was found to be significantly associated with various factors, such as disinfecting routine, method of disinfection, and department of the hospital (p < 0.05). A higher rate of bacterial contamination was observed on the diaphragm of the stethoscope (12.64%) and among HCWs who overlooked hand hygiene practices (45.45%). The prevalence of methicillin-resistant S. aureus (MRSA) was 44.44%, and approximately half of the Gram-negative isolates (47%) were multidrug resistant (MDR). Imipenem (81.25%) and chloramphenicol (83.33%) were found to be the most effective antibiotics for Gram-negative and Gram-positive bacteria, respectively. Phenotypic screening showed that 43.75% of isolates were ESBL producers, and 18.75% were MBL producers, but blaCTX-M and blaVIM genes were detected in only 31.25% and 6.25% of isolates, respectively. The results of the study call for effective stethoscope disinfection practices along with the judicious use of antibiotics by HCWs in order to minimize cross-contamination, emergence of resistance, and spread of nosocomial infections in clinical settings.

2.
Case Rep Pediatr ; 2019: 4740504, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30729056

RESUMO

INTRODUCTION: Moraxella catarrhalis are part of the normal flora of the human respiratory tract and are known to have low pathogenic potential. The organism is rarely reported in the literature as the causative agent of meningitis. We report the first case of early-onset neonatal meningitis associated with M. catarrhalis from Nepal. CASE REPORT: A 3-day-old baby with fever and yellowish discolouration of the body since 48 hrs was admitted to the neonatal ward. The baby developed 3 episodes of seizures in the form of uprolling of eyes on the first day of admission during phototherapy course for raised serum bilirubin. Sepsis screen was positive, and meningitis was confirmed as the cerebrospinal fluid culture grew M. catarrhalis. Cranial ultrasound scan was normal. The baby received a 21-day course of intravenous cefotaxime and amikacin. Recovery has been uneventful to date. CONCLUSION: Neonatal meningitis is a life-threatening infection. This case report presents an uncommon aetiology of neonatal meningitis which can be misidentified in the diagnostic bacteriology laboratory in resource constraints area like ours.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...