Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Invest Ophthalmol Vis Sci ; 57(13): 5383-5392, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27737459

RESUMO

PURPOSE: To characterize the effect of lubricant composition and in vitro ageing on the coefficient of friction (CoF) of a wide range of commercially available soft contact lenses (SCLs). METHODS: The CoF of SCLs was characterized by means of microtribometry against a mucin-coated glass disk. One reusable (RU) silicone-hydrogel (SiHy) lens, senofilcon A, and two daily disposable (DD) lenses, etafilcon A (hydrogel) and nelfilcon A (hydrogel), were tested under different lubricant solutions, including a tear-like fluid (TLF) containing proteins and lipids. Five RU (balafilcon A [SiHy], comfilcon A [SiHy], etafilcon A [hydrogel], lotrafilcon B [SiHy], senofilcon A [SiHy]) and five DD (delefilcon A [SiHy], etafilcon A [hydrogel; two lens types], narafilcon A [SiHy], nelfilcon A [hydrogel]) lenses were tested before and after exposure to an in vitro ageing process, consisting of continuous immersion and withdrawal from TLF for 18 hours. The CoF in TLF was further compared to previously published data collected in a different lubricant. RESULTS: After in vitro ageing, three RU (balafilcon A, etafilcon A, comfilcon A) and three DD (delefilcon A, etafilcon A, nelfilcon A) lenses displayed a significant increase in CoF (P < 0.05). Lenses that contained poly (vinyl pyrrolidone; PVP) showed unaltered CoF after ageing. CONCLUSIONS: An in vitro methodology to simulate in vivo wearing of contact lenses has been proposed. The results suggest that certain lens materials show increased CoF after ageing, with potential clinical implications. The results indicate that the presence of a persistent wetting agent is of advantage to maintain a low CoF after prolonged wearing.


Assuntos
Lentes de Contato Hidrofílicas , Teste de Materiais/métodos , Lágrimas/metabolismo , Desenho de Equipamento , Fricção , Humanos , Lubrificantes Oftálmicos/farmacologia
2.
Cornea ; 34(9): 1179-85, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26203747

RESUMO

PURPOSE: A novel property evaluation methodology was used to determine the elusive value for the human corneal coefficient of friction (CoF). METHODS: Using a microtribometer on 28 fresh human donor corneas with intact epithelia, the CoF was determined in 4 test solutions (≥5 corneas/solution): tear-mimicking solution (TMS) in borate-buffered saline (TMS-PS), TMS in phosphate-buffered saline (TMS-PBS), TMS with HEPES-buffered saline (TMS-HEPES), and tear-like fluid in PBS (TLF-PBS). RESULTS: Mean (SD) CoF values ranged from 0.006 to 0.015 and were 0.013 (0.010) in TMS-PS, 0.006 (0.003) in TMS-PBS, 0.014 (0.005) in TMS-HEPES, and 0.015 (0.009) in TLF-PBS. Statistically significant differences were shown for TMS-PBS versus TLF (P = 0.0424) and TMS-PBS versus TMS-HEPES (P = 0.0179), but not for TMS-PBS versus TMS-PS (P = 0.2389). CONCLUSIONS: Successful measurement of the fresh human corneal tissue CoF was demonstrated, with values differing in the evaluated buffer solutions, within this limited sample size.


Assuntos
Córnea/fisiologia , Fricção/fisiologia , Teste de Materiais/instrumentação , Modelos Biológicos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Lubrificação , Masculino , Estresse Mecânico , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...