1.
Am J Orthopsychiatry ; 71(1): 38-48, 2001 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11271715

RESUMO

Expectations of the adoption reunion process, responses to disappointments, and factors that influence reunion outcomes are investigated in a qualitative study of ten adult adoptees and ten birthmothers. Themes derived from interviews with participants are analyzed and explored, and implications for clinical practice and research are presented.


Assuntos
Adoção/psicologia , Relações Mãe-Filho , Enquadramento Psicológico , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Motivação
2.
Spine (Phila Pa 1976) ; 20(19): 2119-29, 1995 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-8588169

RESUMO

STUDY DESIGN: Two laboratory studies and one field study evaluated the safety and test-retest reliability of a new test of lift capacity. The first two studies were conducted in a carefully controlled laboratory setting. The first study investigated the safety and intra-rater reliability of the EPIC Lift Capacity test protocol with healthy adult subjects. The second study assessed the safety and inter-rater reliability of the test with disabled subjects. The third study was conducted in the field with 65 evaluators and investigated the safety and intra-rater reliability of the test with healthy adult subjects. OBJECTIVE: To assess the safety and reliability of a new test of lift capacity. SUMMARY OF BACKGROUND DATA: A new test of lift capacity has been developed. Test development occurred within the context of ergonomic standards and guide-lines of the major professional associations and public agencies that govern test development in the United States. METHODS: In study no. 1, 26 healthy subjects participated. In study no. 2, 14 disabled subjects participated. In study no. 3, 318 healthy subjects participated. After subjects underwent basic screening and warm-up, the EPIC Lift Capacity test was administered. One to 2 weeks later, the test was administered again. Correlations between the times of testing were calculated. RESULTS: No subjects were injured. Hamstring soreness the next day that resolved without complication was reported by some healthy subjects. None of the disabled subjects reported new symptoms. CONCLUSION: The safety and reliability of the EPIC Lift Capacity test was adequately demonstrated in a laboratory setting and across multiple field sites with evaluators who have varying types and degrees of professional preparation.


Assuntos
Pessoas com Deficiência , Remoção , Adulto , Lesões nas Costas , Fenômenos Biomecânicos , Estudos de Casos e Controles , Ergonomia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Avaliação da Capacidade de Trabalho
SELEÇÃO DE REFERÊNCIAS