Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Lab Chip ; 19(22): 3899-3908, 2019 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-31641709

RESUMO

Dilatometric strain sensors (DSS) that work based on detection of volume change in microfluidic channels; i) are highly sensitive to biaxial strain, ii) can be fabricated using only soft and transparent materials, and iii) are easy to integrate with smart-phones. These features are especially attractive for contact lens based intraocular pressure (IOP) sensing applications. The inherent flow stabilization of the microfluidic systems is an additional advantage suitable for filtering out rapid fluctuations. Here, we have demonstrated that the low-pass filtering in microfluidic sensors improves the signal-to-noise-ratio for ophthalmic applications. We have fabricated devices with a time constant in the range of 1-200 seconds. We have demonstrated that the device architecture and working liquid viscosity (10-866 cSt) are the two independent factors that determine the sensor time constant. We have developed an equivalent circuit model for the DSS that accurately represents the experimental results thus can be used as a computational model for design and development of microfluidic sensors. For a sensor with the time constant of 4 s, we report that microfluidic signal filtering in IOP monitoring applications can suppress the rapid fluctuations (i.e., the noise due to ocular pulsation, blinking etc.) by 9 dB without the need for electronic components.


Assuntos
Técnicas Analíticas Microfluídicas , Ruído , Dispositivos Eletrônicos Vestíveis
2.
Invest Ophthalmol Vis Sci ; 59(12): 5011-5021, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30326068

RESUMO

Purpose: Although widely practiced, surgical treatment of strabismus has varying levels of success and permanence. In this study we investigated adaptive responses within the brain and the extraocular muscles (EOM) that occur following surgery and therefore determine long-term success of the treatment. Methods: Single cell responses were collected from cells in the oculomotor and abducens nuclei before and after two monkeys (M1, M2) with exotropia (divergent strabismus) underwent a strabismus correction surgery that involved weakening of the lateral rectus (LR) and strengthening of the medial rectus (MR) muscle of one eye. Eye movement and neuronal data were collected for up to 10 months after surgery during a monocular viewing smooth-pursuit task. These data were fit with a first-order equation and resulting coefficients were used to estimate the population neuronal drive (ND) to each EOM of both eyes. Results: Surgery resulted in a ∼70% reduction in strabismus angle in both animals that reverted toward presurgical misalignment by approximately 6 months after treatment. In the first month after surgery, the ND to the treated MR reduced in one animal and ND to the LR increased in the other animal, both indicating active neural plasticity that reduced the effectiveness of the treatment. Adaptive changes in ND to the untreated eye were also identified. Conclusions: Active neural and muscle plasticity corresponding to both the treated and the untreated eye determines longitudinal success following surgical correction of strabismus. Outcome of surgical treatment could be improved by identifying ways to enhance "positive" adaptation and limit "negative" adaptation.


Assuntos
Exotropia/cirurgia , Plasticidade Neuronal/fisiologia , Músculos Oculomotores/cirurgia , Procedimentos Cirúrgicos Oftalmológicos , Animais , Modelos Animais de Doenças , Exotropia/fisiopatologia , Movimentos Oculares/fisiologia , Macaca mulatta , Neurônios Motores/fisiologia , Músculos Oculomotores/fisiopatologia , Acompanhamento Ocular Uniforme/fisiologia , Visão Binocular/fisiologia
3.
Lab Chip ; 18(22): 3471-3483, 2018 11 06.
Artigo em Inglês | MEDLINE | ID: mdl-30276409

RESUMO

Wearable technologies have potential to transform healthcare by providing continuous measurements of physiological parameters. Sensors that passively monitor physiological pressure without using electronic components are ideal for wearable contact lenses because they are easy to interface with the cornea and the external environment. Here, we report a passive integrated microfluidic sensor with a novel transduction mechanism that converts small strain changes into a large fluidic volume expansion, detectable by a smart-phone camera. The optimization of the sensor architecture and material properties results in a linear and stable sensor response. We have shown that the sensor has a detection limit of <0.06% for uniaxial and <0.004% for biaxial strain. We embedded our sensor in silicone contact lenses and measured the intraocular pressure induced strain in porcine eyes in the physiological range. The sensor's continuous operation capability for >19 hours and a lifetime reaching >7 months demonstrate its potential for long-term ophthalmic monitoring applications.


Assuntos
Pressão Intraocular , Dispositivos Lab-On-A-Chip , Monitorização Fisiológica/instrumentação , Estresse Mecânico , Dispositivos Eletrônicos Vestíveis , Animais , Desenho de Equipamento , Suínos
4.
Vision (Basel) ; 2(4)2018 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-31735902

RESUMO

To efficiently use its finite resources, the visual system selects for further processing only a subset of the rich sensory information. Visual masking and spatial attention control the information transfer from visual sensory-memory to visual short-term memory. There is still a debate whether these two processes operate independently or interact, with empirical evidence supporting both arguments. However, recent studies pointed out that earlier studies showing significant interactions between common-onset masking and attention suffered from ceiling and/or floor effects. Our review of previous studies reporting metacontrast-attention interactions revealed similar artifacts. Therefore, we investigated metacontrast-attention interactions by using an experimental paradigm, in which ceiling/floor effects were avoided. We also examined whether metacontrast masking is differently influenced by endogenous and exogenous attention. We analyzed mean absolute-magnitude of response-errors and their statistical distribution. When targets are masked, our results support the hypothesis that manipulations of the levels of metacontrast and of endogenous/exogenous attention have largely independent effects. Moreover, statistical modeling of the distribution of response-errors suggests weak interactions modulating the probability of "guessing" behavior for some observers in both types of attention. Nevertheless, our data suggest that any joint effect of attention and metacontrast can be adequately explained by their independent and additive contributions.

5.
Atten Percept Psychophys ; 78(5): 1363-80, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27032801

RESUMO

Visual masking and attention have been known to control the transfer of information from sensory memory to visual short-term memory. A natural question is whether these processes operate independently or interact. Recent evidence suggests that studies that reported interactions between masking and attention suffered from ceiling and/or floor effects. The objective of the present study was to investigate whether metacontrast masking and attention interact by using an experimental design in which saturation effects are avoided. We asked observers to report the orientation of a target bar randomly selected from a display containing either two or six bars. The mask was a ring that surrounded the target bar. Attentional load was controlled by set-size and masking strength by the stimulus onset asynchrony between the target bar and the mask ring. We investigated interactions between masking and attention by analyzing two different aspects of performance: (i) the mean absolute response errors and (ii) the distribution of signed response errors. Our results show that attention affects observers' performance without interacting with masking. Statistical modeling of response errors suggests that attention and metacontrast masking exert their effects by independently modulating the probability of "guessing" behavior. Implications of our findings for models of attention are discussed.


Assuntos
Atenção/fisiologia , Mascaramento Perceptivo/fisiologia , Estimulação Luminosa/métodos , Análise e Desempenho de Tarefas , Percepção Visual/fisiologia , Humanos , Memória de Curto Prazo/fisiologia
6.
Invest Ophthalmol Vis Sci ; 56(11): 6423-32, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26444723

RESUMO

PURPOSE: Strabismic patients can perceptually suppress information from one eye to avoid double vision. However, evidence from prior studies shows that some parts of the visual field of the deviated eye are not suppressed. Our goal here was to investigate whether motion information available only to the deviated eye can be utilized by the oculomotor system to drive eye movements. METHODS: Binocular eye movements were acquired in two exotropic monkeys in a dichoptic viewing task in which the fixating eye viewed a stationary spot and the deviated eye viewed a 10° × 10° stationary patch that contained a drifting grating stimulus moving at 10°/s to the right or left for 20 seconds. Spatial location and contrast of the grating were systematically varied in subsequent trials. For each trial, mean slow-phase velocity of the optokinetic nystagmus (OKN) elicited by grating motion was calculated. RESULTS: We found that OKN responses can be elicited by a motion stimulus presented to the foveal region of the deviated eye. Optokinetic nystagmus magnitude varied depending on which eye was viewing the drifting grating and correlated well with fixation preference and fixation stability (indicators of amblyopia). The magnitude of OKN increased for increased relative contrast of the motion stimulus compared to the fixation spot. CONCLUSIONS: Our results show that motion information available only to the deviated eye can drive optokinetic eye movements. We conclude that the brain has access to visual information from portions of the deviated eye (including the fovea) in strabismus that it can use to drive eye movements.


Assuntos
Nistagmo Optocinético/fisiologia , Estrabismo/fisiopatologia , Visão Binocular/fisiologia , Animais , Modelos Animais de Doenças , Macaca mulatta , Estimulação Luminosa
7.
Vision Res ; 115(Pt A): 23-39, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26238247

RESUMO

A stimulus (mask) reduces the visibility of another stimulus (target) when they are presented in close spatio-temporal vicinity of each other, a phenomenon called visual masking. Visual masking has been extensively studied to understand dynamics of information processing in the visual system. In this study, we adopted a statistical point of view, rather than a mechanistic one, to investigate how mask-related activities might influence target-related ones within the context of visual masking. We modeled the distribution of response errors of human observers in three different visual masking experiments, namely para-/meta-contrast masking, pattern masking by noise, and pattern masking by structure. We adopted statistical models, which have been used previously in studies of visual short-term memory, to capture response characteristics of observers under masking conditions. We tested the following scenarios: (i) mask activity may reduce a target's signal-to-noise ratio (SNR) without interfering with its encoding precision. (ii) Mask activity may "interfere" with the encoding of a target and cause decreased precision in observer's reports. (iii) Decreased performance due to masking may result from the confusion or "misbinding" of a mask's features with those of the target, when they are similar as in the case of pattern masking by structure. Our results show that in all three types of masking, the reduction of a target's SNR was the primary process whereby masking occurred. A significant decrease, correlated with masking strength, in the precision of the target's encoding was observed in para-/meta-contrast and pattern masking by structure, but not in pattern masking by noise. We interpret these findings as the mask reducing the target's SNR (i) by suppressing or interrupting the signal of the target in para-/meta-contrast, (ii) by increasing noise in pattern masking by noise, and (iii) a combination of the two in pattern masking by structure.


Assuntos
Modelos Estatísticos , Reconhecimento Visual de Modelos/fisiologia , Mascaramento Perceptivo/fisiologia , Sensibilidades de Contraste/fisiologia , Humanos , Memória de Curto Prazo/fisiologia , Estimulação Luminosa/métodos , Tempo de Reação/fisiologia , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...