Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Thromb Res ; 96(3): 213-7, 1999 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-10588464

RESUMO

The template bleeding time is still the screening test for defects of platelet function, although it is an invasive and poorly reproducible technique. The PFA-100 measures platelet function at high shear. Whole blood is aspirated through a capillary to an aperture of a membrane coated with platelet agonists. The system measures the time required to obtain occlusion of the aperture by a platelet plug (closure time). We measured the closure times in the PFA-100 system and the bleeding time in seven patients with delta-storage pool deficiency, 10 patients with "primary secretion defect" (not due to abnormalities of platelet granules or the arachidonate pathway), and 40 controls. Measurements were repeated I and 4 hours after intravenous infusion of desmopressin in six delta-storage pool deficiency and eight primary secretion defect patients. Baseline bleeding time and closure times with the collagen/epinephrine cartridge were longer in delta-storage pool deficiency and primary secretion defect patients than in controls. In contrast, closure times with the collagen/adenosine diphosphate cartridge were normal in both delta-storage pool deficiency and primary secretion defect patients. Treatment with desmopressin increased the plasma von Willebrand Factor levels, shortened the prolonged bleeding time, shortened the closure times with the collagen/adenosine diphosphate cartridge, and normalized the closure times with the collagen/ epinephrine cartridge. Therefore, the PFA-100 test may be a less invasive alternative to the bleeding time in the diagnosis and therapeutic monitoring of patients with platelet secretion defects. The collagen/epinephrine cartridge is more sensitive than the collagen/adenosine diphosphate cartridge to defects of platelet secretion.


Assuntos
Tempo de Sangramento/instrumentação , Transtornos Plaquetários/sangue , Plaquetas/metabolismo , Testes de Função Plaquetária/instrumentação , Adulto , Transtornos Plaquetários/congênito , Plaquetas/efeitos dos fármacos , Estudos de Avaliação como Assunto , Feminino , Humanos , Masculino , Programas de Rastreamento/instrumentação , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Adesividade Plaquetária/efeitos dos fármacos , Agregação Plaquetária/efeitos dos fármacos , Deficiência do Pool Plaquetário/sangue
2.
Thromb Haemost ; 82(1): 35-9, 1999 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10456451

RESUMO

We have evaluated platelet function at high shear with the PFA-100 system in different subtypes of von Willebrand disease (vWD), before and after the intravenous infusions of desmopressin or a factor-VIII/von Willebrand factor (vWF) concentrate. Closure times with the PFA-100 system were determined for both the collagen/ADP and the collagen/epinephrine cartridges in 52 patients with vWD (9 type 1 "platelet normal", 5 type 1 "platelet-discordant", 8 type 1 "platelet-low", 6 type 2A, 9 type 2B, 6 type 2M Vicenza. 6 type 3 and 3 acquired vWD) and 40 controls. Measurements were repeated 1 and 4 h after the i.v. infusion of desmopressin (0.3 microg/Kg) in 26 patients with types 1, type 2M Vicenza or type 2A vWD, or of a factorVIII/vWF concentrate (Alphanate HT, 60 U/Kg) in 4 patients with type 3 vWD. At all time points, vWF plasma levels and the bleeding time (Symplate II) were also determined. Baseline closure times were longer in vWD patients than in controls with both the collagen/ADP and the collagen/ epinephrine cartridges. The sensitivity of the PFA-100 system (88% and 87% with the two cartridges) was higher than that of the bleeding time (65%). Treatment with desmopressin normalized the closure times in patients with type 1 "platelet-normal" or type 2M Vicenza vWD, had no significant effects in patients with type 1 "platelet-low", type 1 "platelet-discordant" or type 2A vWD. Infusion of a factorVIII/vWF concentrate in patients with type 3 vWD slightly shortened their prolonged closure times. In general, changes in PFA-100 were paralleled by shortenings of the bleeding times and increases in plasma vWF levels. The PFA-100 test reflects vWF-dependent platelet function under high shear stress and could be useful in the diagnosis and therapeutic monitoring of patients with vWD.


Assuntos
Plaquetas/fisiologia , Equipamentos e Provisões , Ativação Plaquetária , Doenças de von Willebrand/sangue , Desamino Arginina Vasopressina/administração & dosagem , Hemostáticos/administração & dosagem , Humanos , Infusões Intravenosas , Doenças de von Willebrand/tratamento farmacológico , Doenças de von Willebrand/fisiopatologia , Fator de von Willebrand/administração & dosagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...