Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Med Phys ; 50(10): 6589-6599, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37278345

RESUMO

BACKGROUND: Ocular melanoma is a rare kind of eye malignancy that threatens the patient's eyesight. Radiotherapy and surgical removal are the most commonly used therapeutic modalities, and nanomedicine has lately entered this field. Brachytherapy using Ruthenium-106 (106 Ru) ophthalmic plaques has been used for decades to treat ocular melanoma, with the applicator placed on the patient's eyes until the prescribed dose reaches the tumor apex. PURPOSE: To investigate the efficiency of hydrogen nanobubbles (H2 -NBs) employment during intraocular melanoma brachytherapy using a 106 Ru electron emitter plaque. METHODS: The Monte Carlo (MC) simulation and experimental investigation using a 3D-designed phantom and thermoluminescence dosimetry (TLD) were employed. Various concentrations of H2 -NBs with a diameter of 100 nm were simulated inside tumor tissue. The results were presented as deposited energy and dose enhancement factor (DEF). An equivalent Resin phantom of the human eyeball was made using AutoCAD and 3D-Printer technologies. The glass-bead TLDs dosimeter were employed and placed inside the phantom. RESULTS: Using a 1% concentration of H2 -NBs, a DEF of 93% and 98% were achieved at the tumor apex of 10 mm from the experimental setup and MC simulation, respectively. For simulated concentrations of 0.1%, 0.3%, 0.5%, 1%, and 4% H2 -NBs, a maximum dose enhancement of 154%, 174%, 188%, 200%, and 300% were achieved, respectively, and a dose reduction was seen at about 3 mm from the plaque surface. CONCLUSION: H2 -NBs can be used as an absorbed dose enhancer in 106 Ru eye brachytherapy because of their unique physical characteristics. Reducing plaque implantation time on the patient's eye, reducing sclera absorbed dose, and decreasing the risk of patients' healthy organs irradiation are reported as some of the potential benefits of using H2-NBs.


Assuntos
Braquiterapia , Neoplasias Oculares , Melanoma , Neoplasias Uveais , Humanos , Dosagem Radioterapêutica , Olho/efeitos da radiação , Neoplasias Oculares/radioterapia , Braquiterapia/métodos , Melanoma/radioterapia , Método de Monte Carlo
2.
Cancer Med ; 10(20): 7048-7059, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34453413

RESUMO

This retrospective study has been conducted to validate the performance of deep learning-based survival models in glioblastoma (GBM) patients alongside the Cox proportional hazards model (CoxPH) and the random survival forest (RSF). Furthermore, the effect of hyperparameters optimization methods on improving the prediction accuracy of deep learning-based survival models was investigated. Of the 305 cases, 260 GBM patients were included in our analysis based on the following criteria: demographic information (i.e., age, Karnofsky performance score, gender, and race), tumor characteristic (i.e., laterality and location), details of post-surgical treatment (i.e., time to initiate concurrent chemoradiation therapy, standard treatment, and radiotherapy techniques), and last follow-up time as well as the molecular markers (i.e., O-6-methylguanine methyltransferase and isocitrate dehydrogenase 1 status). Experimental results have demonstrated that age (Elderly > 65: hazard ratio [HR] = 1.63; 95% confidence interval [CI]: 1.213-2.18; p value = 0.001) and tumors located at multiple lobes ([HR] = 1.75; 95% [CI]: 1.177-2.61; p value = 0.006) were associated with poorer prognosis. In contrast, age (young < 40: [HR] = 0.57; 95% [CI]: 0.343-0.96; p value = 0.034) and type of radiotherapy (others include stereotactic and brachytherapy: [HR] = 0.5; 95%[CI]: 0.266-0.95; p value = 0.035) were significantly related to better prognosis. Furthermore, the proposed deep learning-based survival model (concordance index [c-index] = 0.823 configured by Bayesian hyperparameter optimization), outperformed the RSF (c-index = 0.728), and the CoxPH model (c-index = 0.713) in the training dataset. Our results show the ability of deep learning in learning a complex association of risk factors. Moreover, the remarkable performance of the deep-learning-based survival model could be promising to support decision-making systems in personalized medicine for patients with GBM.


Assuntos
Neoplasias Encefálicas/mortalidade , Aprendizado Profundo , Glioblastoma/mortalidade , Adulto , Fatores Etários , Idoso , Teorema de Bayes , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/terapia , Quimiorradioterapia , Metilases de Modificação do DNA/sangue , Enzimas Reparadoras do DNA/sangue , Feminino , Glioblastoma/patologia , Glioblastoma/terapia , Humanos , Isocitrato Desidrogenase/sangue , Avaliação de Estado de Karnofsky , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Modelos de Riscos Proporcionais , Radioterapia/métodos , Estudos Retrospectivos , Fatores Sexuais , Análise de Sobrevida , Proteínas Supressoras de Tumor/sangue
3.
Appl Radiat Isot ; 176: 109866, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34293507

RESUMO

PURPOSE: The use of ocular plaques is a promising treatment option for eye melanoma brachytherapy. Although several studies have been done on various ocular plaques, little is known about the dose characterization of 198Au plaque. MATERIALS AND METHOD: The full mathematical model of the eye phantom, tumor, 106Ru/106Rh CCA, and 198Au plaque were simulated using the Monte Carlo MCNPX code. The dose distribution was measured in the plaque's central axis direction, and a dose profile was also measured at a distance of 2.5 mm from the plaque surface. RESULTS: The findings showed that 198Au plaque has superior dosimetric characteristics than CCA plaque for tumors with a thickness of greater than 3.5 mm, while CCA plaque is better for tumors with a thickness of less than 3.5 mm. The dose to the sclera and choroid is higher in the case of CCA plaque, while the dose to the organs at risk (lens and optic nerve) is greater in the case of 198Au applicator. In the case of 198Au plaque, however, the dose to sensitive organs was within their permissible dose range. CONCLUSION: In the treatment of medium and large tumors, 198Au plaque is more successful than CCA plaque. It can produce a much more homogeneous lateral dose profile in the target. In the treatment of dome-shaped tumors, 198Au plaque may be more successful than CCA plaque. As a result, the tumor's shape influences the plaque type selection.


Assuntos
Braquiterapia/métodos , Neoplasias Oculares/radioterapia , Radioisótopos de Ouro/uso terapêutico , Melanoma/radioterapia , Dosagem Radioterapêutica , Radioisótopos de Ouro/administração & dosagem , Humanos , Método de Monte Carlo
4.
Med Phys ; 48(9): 5423-5439, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34173989

RESUMO

PURPOSE: Dose calculation of kilovoltage x rays used in Image-Guided Radiotherapy has been investigated in recent years using various methods. Among these methods are model-based ones that suffer from inaccuracies in high-density materials and at interfaces when used in the kilovoltage energy range. The main reason for this is the use of water energy deposition kernels and simplifications employed such as density scaling in heterogeneous media. The purpose of this study was to produce and characterize material-specific energy deposition kernels, which could be used for dose calculations in this energy range. These kernels will also have utility in dose calculations in superficial radiation therapy and orthovoltage beams utilized in small animal irradiators. METHODS: Water energy deposition kernels with various resolutions; and high-resolution, material-specific energy deposition kernels were generated in the energy range of 10-150 kVp, using the EGSnrc Monte Carlo toolkit. The generated energy deposition kernels were further characterized by calculating the effective depth of penetration, the effective radial distance, and the effective lateral distance. A simple benchmarking of the kernels against Monte Caro calculations has also been performed. RESULTS: There was good agreement with previously reported water kernels, as well as between kernels with different resolution. The evaluation of effective depth of penetration, and radial and laterals distances, defines the relationship between energy, material density, and the shape of the material-specific kernels. The shape of these kernels becomes more forwardly scattered as the energy and material density are increased. The comparison of the dose calculated using the kernels with Monte Carlo provides acceptable results. CONCLUSIONS: Water and material-specific energy deposition kernels in the kilovoltage energy range have been generated, characterized, and compared to previous work. These kernels will have utility in dose calculations in this energy range once algorithms capable of employing them are fully developed.


Assuntos
Algoritmos , Terapia por Raios X , Animais , Método de Monte Carlo , Radiografia , Radiometria , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Raios X
5.
Brachytherapy ; 20(2): 420-425, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33317965

RESUMO

PURPOSE: Iridium-192 brachytherapy dose enhancement by gold nanoparticles was investigated in five different tumor tissues to observe the tissue-related differences as an effective environmental factor in the applications of nanoparticles as radio-enhancer agents. METHODS AND MATERIALS: The brachytherapy high-dose-rate source of BEBIG Ir-192, a tumor volume with five different tissues including water, Plexiglas, soft tissue, adipose, and bone with and without a uniform distribution of gold nanoparticles were mimicked by MCNPX Monte Carlo simulation code using lattice feature. Dose enhancement factors in the tumor volume were measured separately regarding the types of tissue, and a previous study using GEometry ANd Tracking 4 simulation was used for result validation. RESULTS: The results demonstrated that various types of tissue, as the host of gold nanoparticles, lead to different dose enhancement level, so that the bone and adipose have the lowest and the highest amount of dose enhancement factor with values 20.8% and 39.75%, respectively. The maximum difference of 4.8% was achieved from data benchmarking. CONCLUSIONS: The results of this study indicate that the MCNPX code can be used as a valid tool for dose measurement in the presence of nanoparticles. Moreover, tissue types of tumor as an environmental feature, alongside with the nanoparticle's size and concentration as well as the conditions of radiotherapy, should be considered in the dose calculation.


Assuntos
Braquiterapia , Nanopartículas Metálicas , Braquiterapia/métodos , Simulação por Computador , Ouro , Humanos , Método de Monte Carlo , Dosagem Radioterapêutica
6.
Int J Radiat Biol ; 97(2): 179-193, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-32970517

RESUMO

PURPOSE: The aim of this study was to evaluate the effects of oleuropein radiation protection and to find an effective radioprotector. MATERIALS AND METHOD: Human mononuclear cells were treated with oleuropein at the concentration of 100 µM (optimum concentration), incubated for 24 h, and then exposed to 2 Gy gamma-rays. The anti-radiation effect of oleuropein was assessed by MTT assay, flow cytometry, comet assay, and micronucleus (MN) assay. RESULTS: It was found that pretreatment with oleuropein (25, 50, 75, 100, 200, 400, and 800 nM, and 1, 5, 10, 15, 20, 25, 30, 40, 50, 75, 100, 125, 150, 175, and 200 µM) significantly increased the percentage of cell viability compared to the irradiated group (p < .001). Moreover, oleuropein treatment with the above concentrations defined without gamma-ray did not show any cytotoxicity effect in human mononuclear cells. The LD50/24h dose was calculated as 2.9 Gy, whereas by 200, 150, 50, and 100 µM oleuropein prior to radiation (1, 2,and 4 Gy), radiation LD50/24h increased to 3.36, 3.54, 3.81, and >4 Gy, in that order. A very noticeable dose-modifying factor (DMF) of 1.16, 1.23, 1.31, and 1.72 was observed for 200, 150, 50, and 100 µM, in order. Therefore, 100 µM of oleuropein was selected as the desirable dose for radio-protection trial, and 2 Gy gamma-rays were used for further research. Human mononuclear cells treatment with oleuropein (100 µM) prior to 2 Gy gamma-rays significantly decreased apoptosis, genomic damage, and MN occurrence in human mononuclear caused by gamma-radiation (p < .001). Furthermore, treatment with oleuropein (100 µM) without radiation did not lead to apoptosis, genotoxicity, or clastogenic effects caused by oleuropein in human mononuclear cells. CONCLUSION: The results revealed that oleuropein is able to significantly reduce cytotoxicity, apoptosis, genotoxic, and clastogenic effects of gamma-rays.


Assuntos
Apoptose/efeitos da radiação , Glucosídeos Iridoides/farmacologia , Linfócitos/efeitos da radiação , Protetores contra Radiação/farmacologia , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Dano ao DNA , Relação Dose-Resposta a Droga , Humanos , Linfócitos/patologia , Testes para Micronúcleos
7.
J Appl Clin Med Phys ; 21(1): 179-190, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31880401

RESUMO

To investigate the effect of image preprocessing, in respect to intensity inhomogeneity correction and noise filtering, on the robustness and reproducibility of the radiomics features extracted from the Glioblastoma (GBM) tumor in multimodal MR images (mMRI). In this study, for each patient 1461 radiomics features were extracted from GBM subregions (i.e., edema, necrosis, enhancement, and tumor) of mMRI (i.e., FLAIR, T1, T1C, and T2) volumes for five preprocessing combinations (in total 116 880 radiomics features). The robustness and reproducibility of the radiomics features were assessed under four comparisons: (a) Baseline versus modified bias field; (b) Baseline versus modified bias field followed by noise filtering; (c) Baseline versus modified noise, and (d) Baseline versus modified noise followed bias field correction. The concordance correlation coefficient (CCC), dynamic range (DR), and interclass correlation coefficient (ICC) were used as metrics. Shape features and subsequently, local binary pattern (LBP) filtered images were highly stable and reproducible against bias field correction and noise filtering in all measurements. In all MRI modalities, necrosis regions (NC: n ̅ ~449/1461, 30%) had the highest number of highly robust features, with CCC and DR >= 0.9, in comparison with edema (ED: n ̅ ~296/1461, 20%), enhanced (EN: n ̅ ~ 281/1461, 19%) and active-tumor regions (TM: n ̅ ~254/1461, 17%). The necrosis regions (NC: n ¯  ~ 449/1461, 30%) had a higher number of highly robust features (CCC and DR >= 0.9) than edema (ED: n ¯  ~ 296/1461, 20%), enhanced (EN: n ¯  ~ 281/1461, 19%) and active-tumor (TM: n ¯  ~ 254/1461, 17%) regions across all modalities. Furthermore, our results identified that the percentage of high reproducible features with ICC >= 0.9 after bias field correction (23.2%), and bias field correction followed by noise filtering (22.4%) were higher in contrast with noise smoothing and also noise smoothing follow by bias correction. These preliminary findings imply that preprocessing sequences can also have a significant impact on the robustness and reproducibility of mMRI-based radiomics features and identification of generalizable and consistent preprocessing algorithms is a pivotal step before imposing radiomics biomarkers into the clinic for GBM patients.


Assuntos
Algoritmos , Glioblastoma/patologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
8.
Appl Biochem Biotechnol ; 190(2): 540-550, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31396886

RESUMO

Use of nanoparticles as carriers of anticancer drugs is a suitable way for targeted drug delivery and reduction of the side effects. This research focuses on a novel drug carrier for therapeutic goals by the bacterial magnetic nanoparticles (magnetosomes). The unique characteristics of magnetosomes make them ideal nanobiotechnological materials. In this study, magnetic nanoparticles of Alphaproteobacterium MTB-KTN90 were labeled with the radioisotope rhenium-188 and optimized the factors affecting the labeling efficiency. The results showed that the labeling efficiency of magnetosomes with rhenium-188 was more than 96%. The optimum concentration of bacterial nanoparticles was 133 mg/ml and the best time for maximum efficiency labeling was 60 min. The labeling stability showed that the 188Re-nanoparticle complexes have good stability in 29 h. The results of magnetic nanoparticles bacterial cytotoxicity on cancer cells AsPC1 did not show significant toxicity to concentration of 100 µg/µl. Finally, the biogenic magnetic nanoparticles labeled with rhenium-188 can be introduced as a valuable candidate for the targeted therapy of tumor with reducing radiation to surrounding healthy tissues.


Assuntos
Alphaproteobacteria/metabolismo , Magnetismo , Nanopartículas , Radioisótopos/química , Radioterapia/métodos , Rênio/química , Linhagem Celular Tumoral , Humanos
9.
Iran J Med Sci ; 44(2): 99-107, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30936596

RESUMO

BACKGROUND: Both mitochondrial dysfunction and aerobic glycolysis are signs of growing aggressive cancer. If altered metabolism of cancer cell is intended, using the glycolysis inhibitor (2-deoxyglucose (2DG)) would be a viable therapeutic method. The AMP-activated protein kinase (AMPK), as a metabolic sensor, could be activated with metformin and it can also launch a p53-dependent metabolic checkpoint and might inhibit cancer cell growth. METHODS: After treatment with 5 mM metformin and/or 500 µM 2DG, the TE1, TE8, and TE11 cellular viability and apoptosis were assessed by MTT, TUNEL, and ELISA methods. The changes in p53 and Bcl-2 genes expression levels were examined using real-time PCR method. Data were analyzed by Kruskal-Wallis test using the SPSS 17.0 software. RESULTS: Metformin and 2DG, alone and in combination, induced apoptosis in the cell lines. Real-time PCR revealed that metformin induced apoptosis in TE8 and TE11 cells by activating p53, down-regulating Bcl-2 expression. The induced apoptosis by 2DG raised by metformin and the combination modulated the expression of Bcl-2 protein in all cell lines and it was more effective in TE11 cell line. CONCLUSION: Metformin induced apoptosis in ESCC by down-regulating Bcl-2 expression, and up-regulating p53 and induced apoptosis increased by 2-deoxy-d-glucose. Thus, the combination therapy is an effective therapeutic strategy for esophageal squamous cell carcinoma.

10.
Ear Nose Throat J ; 97(3): E10-E17, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29554405

RESUMO

Patients with head and neck cancer after radiotherapy often suffer disability such as hearing disorders. In this study, the effect of radiotherapy (RT) on hearing function of patients with head and neck cancer after RT was determined according to the total dose delivered to specific parts of the auditory system. A total of 66 patients treated with primary or postoperative radiation therapy for various cancers in the head and neck region were selected. All patients had audiologic evaluation with pure tone audiometry for the frequencies of 250, 500, 1,000, 2,000, 3,000, 4,000, 6,000, and 8,000 Hz before and immediately after completion of treatment and again 3 months later. The cochlea dose volume histograms of the patients were derived from their computed-tomography-based treatment plans. At study's end, RT-induced auditory complications developed in 33% of patients. The greatest hearing loss (changes >15 dB) occurred immediately after RT at frequencies of 3,000 (14.5%), 4,000 (12.9%), 6,000 (13.6%), and 8,000 Hz (10.6%), and after 3 months of follow-up, at 3,000 (6.8%), 4,000 (7.7%), 6,000 (10.7%), and 8,000 Hz (12.1%). Univariate and multivariate analyses indicated a positive relationship between dose delivered to the cochlea and hearing loss (p < 0.001, r = 0.484). An increased risk of hearing loss was present for patients receiving ≥40 Gy as their mean dose compared with those receiving <30 Gy. We conclude that radiation dose has negative effects on the auditory system. This effect occurs more in high-frequency hearing. The received dose to the cochlea was the main cause of damage to hearing.


Assuntos
Neoplasias Encefálicas/fisiopatologia , Neoplasias de Cabeça e Pescoço/fisiopatologia , Transtornos da Audição/etiologia , Audição/efeitos da radiação , Lesões por Radiação/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Audiometria de Tons Puros , Neoplasias Encefálicas/radioterapia , Feminino , Neoplasias de Cabeça e Pescoço/radioterapia , Transtornos da Audição/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
11.
Radiat Prot Dosimetry ; 178(3): 304-309, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-28981808

RESUMO

Cardiac computed tomography angiography (CCTA) studies have risen concern of radiobiological effects over the patients. Therefore, estimating radiation doses absorbed during CCTA is important. In this study, we compared radiation dose and image quality by using three different retrospective electrocardiography (ECG) protocols. A total of 123 patients undergoing CCTA were divided in three different groups. We used full-dose modulation (CareDose4D) technique in group (1); fixed tube current 200 mAs for group (2); and in group (3), chest circumference was used to adapt tube current (180-200 mAs) and tube potential (100-120 kVp). For groups (1) and (2), tube potential adapted depends on body mass index (BMI) in which it was 100 kVp for BMI < 27 kg/m2, and 120 kVp for BMI ≥ 27 kg/m2. Quantitive assessment of image quality was calculated by measuring signal intensity (SI) and image noise (IN) in the proximal segments of aorta root on left and right coronary arteries. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also calculated by using SI and IN. Two experienced radiologists using a 4-point scale assessed the subjective image quality. Our results show that in group (1), the mean effective dose was 4.46 mSv (range: 1.75-8.6 mSv) and for group (2), the mean effective radiation dose was 5.07 mSv (range: 2.57-9.74 mSv) and in group (3), the mean effective dose was 5.85 mSv (range: 3.36-12.17 mSv). Group (1) representing 12% and 23% decrease in radiation dose comparing by groups (2) and (3). In multivariate analysis, adjusting for BMI, radiation dose for patients with BMI < 27 kg/m2 was significantly different; 2.53 mSv for group (1) compared to 3.54 mSv in group (2) and 5.207 in group (3) (p < 0.0001). In addition, lowering tube potential from 120 to 100 kVp in 200 mAs fixed tube current, represents 27% decrease in radiation dose. The quantitative image quality (IN, SI, SNR and CNR) was not statistically significant among the groups. To sum up, Retrospective-ECG gating may reduce radiation dose by using automatic tube current modulation and 100kVp tube potential with preservation of image quality in patient's whose BMI < 27 kg/m2.


Assuntos
Técnicas de Imagem de Sincronização Cardíaca/métodos , Angiografia por Tomografia Computadorizada/métodos , Doses de Radiação , Radiometria/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Índice de Massa Corporal , Meios de Contraste , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Razão Sinal-Ruído
12.
Lasers Med Sci ; 32(9): 2139-2144, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29075996

RESUMO

Herein, the performance of single-fiber reflectance spectroscopy (SFRS) in detection of cervical pre-cancerous squamous intraepithelial lesions (SIL) was compared with colposcopy. Based on the previous results obtained from 167 samples and finding the contributing parameters in differentiating SILs from non-SILs, a user-friendly interface was developed to detect the SILs using SFRS system. Detection of SILs in 301 patients was performed by both SFRS system and routine colposcopy. In addition to physician-determined sites, four quarters of the cervix were measured by SFRS system and suspicious lesions detected by either method were biopsied. Histopathologic results of the biopsied species were compared to the physician judgments based on colposcopy and the results of SFRS system. SFRS could differentiate between SILs and non-SILs with mean sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of 38.3, 60.9, 15.2, and 84.3%, respectively. These values were obtained as 88.3, 10.6, 15.4, and 83.1% for the colposcopy, respectively. Although sensitivity of SFRS in detection of SILs is about twofold less than the colposcopy, it can reduce the number of unnecessary biopsies by a factor of more than 5.5. Therefore, the aid of SFRS system to the physician can reduce the number of unnecessary biopsies. On the other hand, both colposcopy and SFRS methods equally suffer from low detection worth in terms of positive/negative predictive values. In conclusion, using the online, simple and non-invasive SFRS system to choose between several suspicious sites in a patient in the clinic may be recommended.


Assuntos
Colposcopia , Análise Espectral/métodos , Adulto , Algoritmos , Feminino , Humanos , Interface Usuário-Computador , Neoplasias do Colo do Útero/diagnóstico , Displasia do Colo do Útero/diagnóstico
13.
Rep Pract Oncol Radiother ; 22(6): 470-476, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28951698

RESUMO

AIM: The purpose of the present study is to investigate the dependence of micronuclei response on the depth of absorbed dose. BACKGROUND: One of the most common cytogenetic methods used for radiation dosimetry is micronuclei (MN). Being less complex and faster than other methods are two remarkable advantages of the MN method which make it suitable for monitoring of population. In biological dosimetry based on the micronuclei method, the investigation into the dependence of response on the depth in which dose is absorbed is significant, though has received less attention so far. MATERIALS AND METHODS: Blood samples were poured in separate vials to be irradiated at different depths using a linear accelerator system. RESULTS: According to the results, MN, as a function of the absorbed dose, had the best fitness with the linear-quadratic model at all depths. Furthermore, the results showed the dependence of MN response on the depth of absorbed dose. For doses up to 2 Gy, the maximum difference from the reference depth of 1.5 cm was related to the depth of 10 cm; however, by increasing the absorbed dose, the response associated with the depth of 20 cm showed the maximum deviation from the reference depth. CONCLUSIONS: Consequently, it is necessary to apply a correction factor to the biological dosimetry. The correction factor is dependent on the depth and the absorbed dose.

14.
Rev Sci Instrum ; 88(6): 063705, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28667949

RESUMO

Edge-illumination x-ray phase contrast imaging (EI XPCI) is a non-interferometric phase-sensitive method where two absorption masks are employed. These masks are fabricated through a photolithography process followed by electroplating which is challenging in terms of yield as well as time- and cost-effectiveness. We report on the first implementation of EI XPCI with Pt-based metallic glass masks fabricated by an imprinting method. The new tested alloy exhibits good characteristics including high workability beside high x-ray attenuation. The fabrication process is easy and cheap, and can produce large-size masks for high x-ray energies within minutes. Imaging experiments show a good quality phase image, which confirms the potential of these masks to make the EI XPCI technique widely available and affordable.

15.
Rep Pract Oncol Radiother ; 22(4): 284-289, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28507457

RESUMO

AIM: The aim of this study is to evaluate the effect of air within trachea on dose calculations of esophageal HDR brachytherapy treatment planning. BACKGROUND: Dose calculations in esophageal HDR brachytherapy treatment planning systems are greatly based on TG-43 protocol which in all materials are considered to be water equivalent. MATERIALS AND METHODS: A cylindrical PMMA phantom with a tube in the center (neck equivalent phantom) accompanied by Flexitron HDR brachytherapy system was used in this study. Brachytherapy applicators with various diameters were placed inside the esophageal tube and EDR2 film was used for dosimetry. The absorbed dose by reference point of esophageal HDR brachytherapy and anterior wall of trachea were measured and compared with those calculated by Flexiplan treatment planning system. RESULTS: Based on the performed statistical analysis (t-test) with 95% confidence level (t-value >1.96), there was a meaningful difference between the results of film dosimetry and treatment planning at all of the points understudy. CONCLUSION: The meaningful difference between the results of film dosimetry and treatment planning indicates that the trachea inhomogeneity has a considerable effect on dose calculations of Flexiplan treatment planning software featuring the TG-43 dose calculation algorithm. This mismatch can affect the accuracy of performed treatment plan and irradiation.

16.
Appl Radiat Isot ; 123: 69-81, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28260609

RESUMO

Beam shaper is a newly designed device for beam shaping in IOERT. The aim of this study is evaluating the performance of this device for conformal IOERT and preparing it for clinical applications. Dosimetric characteristics for different combinations of energy/field size were determined by ionometric dosimetry, film dosimetry and Monte Carlo simulation. Desirable dosimetric characteristics of beam shaper make it a useful tool for conformal IOERT. Usability of Monte Carlo simulation in any clinical setup of beam shaper was demonstrated.


Assuntos
Radioterapia Conformacional/instrumentação , Terapia Combinada , Simulação por Computador , Elétrons/uso terapêutico , Desenho de Equipamento , Dosimetria Fotográfica , Humanos , Período Intraoperatório , Método de Monte Carlo , Neoplasias/radioterapia , Neoplasias/cirurgia , Aceleradores de Partículas/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Radioterapia Conformacional/estatística & dados numéricos
17.
Bioimpacts ; 6(2): 93-8, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27525226

RESUMO

INTRODUCTION: Human double minute2 (hdm2) level increases in most human malignancies. Therefore, inhibition of tumor growth and also induction of radiosensitivity may be provided by hdm2 inhibitors. The effects of hdm2-siRNA on hdm2 protein expression, cell apoptosis rate, and radiosensitivity of human esophageal squamous cell carcinoma (ESCC) were studied. METHODS: The hdm2 gene was silenced in TE1, TE8, and TE11 ESCC cell lines using 200nM siRNA by liposomal transfection method followed by irradiation with 0.5, 1, 2, 4, and 6 Gy γ-rays in vitro. The gene expression levels were evaluated by real time PCR and Western Blotting methods. MTT, TUNEL, and also colony forming assays were used to compare the radiosensitivity of the cell lines before and after the treatments. RESULTS: Hdm2-siRNA reduced the hdm2 protein as compared to the vehicle control and scrambled groups, and also increased the radiation-induced apoptosis especially in TE11 cells. The related dose reduction factors (DRFs) for the silenced TE1, TE8, and TE11 cells calculated to be 1.20, 1.30, and 2.75, respectively. CONCLUSION: Increasing radiosensitivity of tumor cells may be provided by silencing the oncogenes.

18.
J Appl Clin Med Phys ; 16(2): 5017, 2015 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-26103175

RESUMO

The specific design of the mobile dedicated intraoperative radiotherapy (IORT) accelerators and different electron beam collimation system can change the dosimetric characteristics of electron beam with respect to the conventional accelerators. The aim of this study is to measure and compare the dosimetric characteristics of electron beam produced by intraoperative and conventional radiotherapy accelerators. To this end, percentage depth dose along clinical axis (PDD), transverse dose profile (TDP), and output factor of LIAC IORT and Varian 2100C/D conventional radiotherapy accelerators were measured and compared. TDPs were recorded at depth of maximum dose. The results of this work showed that depths of maximum dose, R90, R50, and RP for LIAC beam are lower than those of Varian beam. Furthermore, for all energies, surface doses related to the LIAC beam are substantially higher than those of Varian beam. The symmetry and flatness of LIAC beam profiles are more desirable compared to the Varian ones. Contrary to Varian accelerator, output factor of LIAC beam substantially increases with a decrease in the size of the applicator. Dosimetric characteristics of beveled IORT applicators along clinical axis were different from those of the flat ones. From these results, it can be concluded that dosimetric characteristics of intraoperative electron beam are substantially different from those of conventional clinical electron beam. The dosimetric characteristics of the LIAC electron beam make it a useful tool for intraoperative radiotherapy purposes.


Assuntos
Elétrons , Modelos Teóricos , Aceleradores de Partículas/instrumentação , Radiometria/métodos , Radioterapia Conformacional/instrumentação , Simulação por Computador , Desenho de Equipamento , Humanos , Período Intraoperatório , Método de Monte Carlo , Dosagem Radioterapêutica
19.
J Cancer Res Ther ; 11(4): 765-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26881515

RESUMO

AIM: Dosimetric properties of a CCD camera-based Electronic Portal Imaging Device (EPID) for clinical dosimetric application have been evaluated. Characteristics obtained by EPID also compared with commercial 2D array of ion chambers. MATERIALS AND METHODS: Portal images acquired in dosimetry mode then exported raw fluence or uncorrected images were investigated. Integration time of image acquisition mode has adjusted on 1 s per frame. RESULTS: As saturation of camera of the EPID, dose response does not have linear behavior. The slight nonlinearity of the camera response can be corrected by a logarithmic expression. A fourth order polynomial regression model with coefficient of determination of 0.998 predicts a response to absolute dose values at less than 50 cGy. A field size dependent response of up to 7% (0.99-1.06) relative OCTAVIUS detector measurement was found. The EPID response can be fitted by a cubic regression for field size changes, yielded coefficient of determination of 0.999. CONCLUSIONS: These results indicate that the EPID is well suited for accurate dosimetric purposes, the major limitation currently being due to integration time and dead-time in frame acquisition.


Assuntos
Equipamentos e Provisões Elétricas , Processamento de Imagem Assistida por Computador/instrumentação , Neoplasias/radioterapia , Radiometria/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Dosagem Radioterapêutica
20.
Arch Iran Med ; 17(9): 602-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25204475

RESUMO

BACKGROUND: We assessed the performance of single fiber reflectance spectroscopy (SFRS) in discriminating cervical squamous intraepithelial lesions (SIL) from non-SILs and the probable influence of environmental factors on its performance. METHODS: SFRS was used to measure the reflected light from cervical tissue of 157 patients undergoing standard colposcopy. Seven parameters extracted from the spectra in addition to two biographic parameters were used to compare the biopsy-confirmed SILs with non-SILs. The tissue classification capability was reported by receiver operating characteristic (ROC) curves. In addition, the effect of five interfering parameters, including the probe, clinician, hospital, menopausal status and age of the patient on spectroscopic parameters were investigated by the Kruskal-wallis test. RESULTS: The average vessel diameter and beta-carotene concentration were found to be the parameters contributing to tissue discrimination. SFRS could differentiate between SILs and non-SILs with sensitivity, specificity and area under the ROC curve of 63% ± 6%, 68% ± 6% and 0.69 ± 0.04, respectively. None of the five environmental parameters interfered with the discriminator spectroscopic parameters. CONCLUSIONS: SFRS was found as a noninvasive, fast, compact, cost-effective, independent, and acceptably accurate system to help the clinician to reduce the number of unnecessary biopsies during the colposcopy procedure.


Assuntos
Imagem Óptica/métodos , Lesões Pré-Cancerosas/diagnóstico , Análise Espectral/métodos , Neoplasias do Colo do Útero/diagnóstico , Adulto , Fatores Etários , Colo do Útero/patologia , Feminino , Humanos , Lesões Pré-Cancerosas/patologia , Neoplasias do Colo do Útero/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...