Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Echocardiography ; 22(5): 367-73, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15901286

RESUMO

Prior validation studies have established that simultaneously measured catheter (cath) and Doppler mean pressure gradients (MPG) correlate closely in evaluation of aortic stenosis (AS). In clinical practice, however, cath and Doppler are rarely performed simultaneously; which may lead to discrepant results. Accordingly, our aim was to ascertain agreement between these methods and investigate factors associated with discrepant results. We reviewed findings in 100 consecutive evaluations for AS performed in 97 patients (mean age 72 +/- 10 yr) in which cath and Doppler were performed within 6 weeks. We recorded MPG, aortic valve area (AVA), cardiac output, and ejection fraction (EF) by both methods. Aortic root diameter, left ventricular end-diastolic dimension (LVIDd) and posterior wall thickness (PWT) were measured by echocardiography and gender, heart rate, and heart rhythm were also recorded. An MPG discrepancy was defined as an intrapatient difference > 10 mmHg. Mean pressure gradients by cath and Doppler were 36 +/- 22 mmHg and 37 +/- 20 mmHg, respectively (P = 0.73). Linear regression showed good correlation (r = 0.82) between the techniques. An MPG discrepancy was found in 36 (36%) of 100 evaluations; in 19 (53%) of 36 evaluations MPG by Doppler was higher than cath, and in 17 (47%) of 36, it was lower. In 33 evaluations, EF differed by >10% between techniques. Linear regression analyses revealed that EF difference between studies was a significant predictor of MPG discrepancy (P = 0.004). Women had significantly higher MPG than men by both cath and Doppler (43 +/- 25 mmHg versus 29 +/- 15 mmHg [P = 0.001]; 42 +/- 23 mmHg versus 32 +/- 15 mmHg [P = 0.014], respectively). Women exhibited discrepant results in 23 (47%) of 49 evaluations versus 13 (25%) of 51 evaluations in men (P = 0.037). After adjustment for women's higher MPG, there was no statistically significant difference in MPG discrepancy between genders (P = 0.22). No significant interactions between MPG and aortic root diameter, relative wall thickness (RWT), heart rate, heart rhythm, cardiac output, and time interval between studies were found. In clinical practice, significant discrepancies in MPG were common when cath and Doppler are performed nonsimultaneously. No systematic bias was observed and Doppler results were as likely yield lower as higher MPGs than cath. EF difference was a significant predictor of discrepant MPG. Aortic root diameter, relative wall thickness, heart rate, heart rhythm, cardiac output, presence or severity of coronary artery disease, and time interval between studies were not predictors of discrepant results.


Assuntos
Estenose da Valva Aórtica/diagnóstico , Cateterismo Cardíaco/métodos , Ecocardiografia Doppler/métodos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Estenose da Valva Aórtica/fisiopatologia , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Análise de Regressão , Fatores Sexuais , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Pressão Ventricular/fisiologia , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA