RESUMO
Fibular head avulsion fractures are rare injuries determined by traction of the fibular attachment of the lateral collateral ligament (LCL). Surgical treatment is often recommended with different techniques such as tension band fixation or lag screws stabilization. In this article, we describe a fixation technique of fibular head fractures obtained through the use of anchors. A 45-year-old athletic patient came to our attention in our traumatologic service after a motorcycle accident. He reported a complex injury of the posterolateral corner with an avulsion fracture of the left fibular head. We performed a clinical evaluation at the final follow-up visit (six months). We demonstrated that the use of suture anchors may be an effective technique of fixation in avulsion fracture of the fibular head associated with combined posterolateral corner injuries.
Assuntos
Fíbula , Fixação Interna de Fraturas , Fratura Avulsão/cirurgia , Fraturas Ósseas/cirurgia , Fíbula/lesões , Fíbula/cirurgia , Fixação Interna de Fraturas/instrumentação , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
The surgical site contamination and the resulting periprosthetic infections are an important cause of morbidity and socio-economic impact. In total knee arthroplasty, the single-use instrumentation is developed to simplify the surgical procedure, reduce the chance of instrument contamination, improve the operating room efficiency, and reduce overall costs (low cost of instrument washing and sterilization as well as personnel management). Surgical single-use instrumentations on the market are complete with all you need for the surgical procedure-cutting guides, conventional or PSI (patient-specific instrumentation), femoral cutting block, re-cutting block, trials components, alignment rods, inserts, and impactors. In recent years, PSI (patient-specific instrumentation) was introduced. It decreases operative time and blood loss without violating the intramedullary canal. It also allows the surgeon to preoperatively plan the patient's component size, position, and alignment. We reported an average of 30 minutes saved for each surgical procedure, a saving of 60 for each surgical tray. Moreover, we avoided surgery cancellation or delay due to un-sterile, missing, or dysfunctional instruments. We think that this technology is the first step in developing implants that are entirely customized for each patient, and we believe that it will have a more relevant role in knee surgery in the future.