Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Cytometry B Clin Cytom ; 63(1): 28-35, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15624204

RESUMO

BACKGROUND: CD19 is expressed on most B-cell lymphomas; however, the frequency and types of B-cell lymphomas with low-level expression of CD19 are not well characterized. METHODS: We reviewed flow cytometric histograms specifically for decreased CD19 expression on 349 cases analyzed by the Flow Cytometry Laboratory at University Hospitals of Cleveland (Cleveland, Ohio). Results of flow cytometry were correlated with the morphologic diagnosis. RESULTS: Of the cases reviewed, 125 (36%) showed a visible decrease in CD19 expression compared with normal B lymphocytes. Decreased CD19 expression was noted in 79% of follicular lymphomas (27 of 34), 36% of small lymphocytic lymphomas/chronic lymphocytic leukemias (82 of 228), 31% of mantle cell lymphomas (4 of 13), 24% of diffuse large B-cell lymphomas (8 of 33), and 13% of marginal zone B-cell lymphomas/lymphoplasmacytoid lymphomas (4 of 30) and was not observed in any Burkitt lymphoma (0 of 5) or hairy cell leukemia (0 of 6). Decreased CD19 expression was significantly more frequent in follicular lymphomas than in other lymphoma subtypes (P < 0.001). No significant difference was observed in the frequency of decreased CD19 expression based on histologic grade of follicular lymphoma. CONCLUSIONS: Diminished expression of CD19 expression occurs frequently in B-cell lymphomas, in particular follicular lymphoma, and may be helpful in identifying B-cell lymphoma cells in complex cell mixtures such as bone marrow specimens.


Assuntos
Antígenos CD19/imunologia , Citometria de Fluxo/métodos , Linfoma de Células B/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antígenos CD19/análise , Linfócitos B/citologia , Linfócitos B/imunologia , Linfócitos B/metabolismo , Células da Medula Óssea/imunologia , Células da Medula Óssea/metabolismo , Células da Medula Óssea/patologia , Criança , Humanos , Linfoma de Células B/metabolismo , Linfoma de Células B/patologia , Pessoa de Meia-Idade
2.
Am J Clin Pathol ; 118(2): 235-41, 2002 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-12162684

RESUMO

We compared the accuracy and precision of the impedance platelet counts generated by the Beckman Coulter LH 750 and the Sysmex XE 2100 and the optical platelet counts produced by the Advia 120 and the Sysmex XE 2100 withflow cytometric reference platelet counts. Samples analyzed had platelet counts less than 150 x 10(3)/microL (150 x 10(9)/L) with a platelet flag or less than 75 x 10(3)/microL (75 x 10(9)/L) on the Sysmex SE 9500. The 105 samples were run sequentially through each analyzer. Anti-CD41 and anti-CD61 monoclonal antibodies were used for flow cytometric determination of the reference platelet count by the RBC/platelet ratio method. The Beckman Coulter and the Sysmex impedance platelet counts showed better correlation with the reference method than the optical platelet counts by the Advia and the Sysmex. At platelet transfusion thresholds of 10 and 20 x 10(3)/microL (10 and 20 x 10(9)/L), the precision of the impedance methods was somewhat better than that of the optical methods. Current methods of optical platelet counting may not be superior to impedance platelet counts for all patient populations.


Assuntos
Contagem de Plaquetas/instrumentação , Anticorpos Monoclonais , Antígenos CD/análise , Separação Celular , Contagem de Eritrócitos/normas , Citometria de Fluxo , Humanos , Integrina beta3 , Contagem de Plaquetas/normas , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/análise , Glicoproteínas da Membrana de Plaquetas/análise , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...