Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Viruses ; 14(7)2022 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-35891359

RESUMO

Some of the lineages of SARS-CoV-2, the new coronavirus responsible for COVID-19, exhibit higher transmissibility or partial resistance to antibody-mediated neutralization and were designated by WHO as Variants of Interests (VOIs) or Concern (VOCs). The aim of this study was to monitor the dissemination of VOIs and VOCs in Venezuela from March 2021 to February 2022. A 614 nt genomic fragment was sequenced for the detection of some relevant mutations of these variants. Their presence was confirmed by complete genome sequencing, with a correlation higher than 99% between both methodologies. After the introduction of the Gamma VOC since the beginning of the year 2021, the variants Alpha VOC and Lambda VOI were detected as early as March 2021, at a very low frequency. In contrast, the Mu VOI, detected in May 2021, was able to circulate throughout the country. After the detection of the Delta VOC in June 2021, it became the predominant circulating variant. With the arrival of the Omicron VOC in December, this variant was able to displace the Delta one in less than one month.


Assuntos
COVID-19 , SARS-CoV-2 , Sequência de Bases , COVID-19/epidemiologia , Humanos , Mutação , SARS-CoV-2/genética , Glicoproteína da Espícula de Coronavírus , Venezuela/epidemiologia
2.
Infect Genet Evol ; 96: 105147, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34800714

RESUMO

In less than two years since SARS-CoV-2 emerged, the new coronavirus responsible for COVID-19, has accumulated a great number of mutations. Many of these mutations are located in the Spike protein and some of them confer to the virus higher transmissibility or partial resistance to antibody mediated neutralization. Viral variants with such confirmed abilities are designated by WHO as Variants of Concern (VOCs). The aim of this study was to monitor the introduction of variants and VOCs in Venezuela. A small fragment of the viral genome was sequenced for the detection of the most relevant mutations found in VOCs. This approach allowed the detection of Gamma VOC. Its presence was confirmed by complete genome sequencing. The Gamma VOC was detected in Venezuela since January 2021, and in March 2021 was predominant in the East and Central side of the country, representing more than 95% of cases sequenced in all the country in April-May 2021. In addition to the Gamma VOC, other isolates carrying the mutation E484K were also detected. The frequency of this mutation has been increasing worldwide, as shown in a survey of sequences carrying E484K mutation in GISAID, and was detected in Venezuela in many probable cases of reinfection. Complete genome sequencing of these cases allowed us to identify E484K mutation in association with Gamma VOC and other lineages. In conclusion, the strategy adopted in this study is suitable for genomic surveillance of variants for countries lacking robust genome sequencing capacities. In the period studied, Gamma VOC seems to have rapidly become the dominant variant throughout the country.


Assuntos
COVID-19/epidemiologia , COVID-19/virologia , Filogenia , SARS-CoV-2/genética , Genoma Viral , Humanos , Mutação , Reação em Cadeia da Polimerase , Prevalência , Reinfecção/virologia , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/patogenicidade , Venezuela/epidemiologia , Sequenciamento Completo do Genoma
3.
PLoS One ; 16(2): e0247196, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33606828

RESUMO

SARS-CoV-2 is the new coronavirus responsible for COVID-19 disease. The first two cases of COVID-19 were detected in Venezuela on March 13, 2020. The aim of this study was the genetic characterization of Venezuelan SARS-CoV-2 isolates. A total of 7 full SARS-CoV-2 genome sequences were obtained by Sanger sequencing, from patients of different regions of Venezuela, mainly from the beginning of the epidemic. Ten out of 11 isolates (6 complete genomes and 4 partial spike genomic regions) belonged to lineage B, bearing the D614G mutation in the Spike protein. Isolates from the first outbreak that occurred in the Margarita Island harbored an in-frame deletion in its sequence, without amino acids 83-85 of the NSP1 of the ORF1. The search for deletions in 48,635 sequences showed that the NSP1 gene exhibit the highest frequency of deletions along the whole genome. Structural analysis suggests a change in the N-terminal domain with the presence of this deletion. In contrast, isolates circulating later in this island lacked the deletion, suggesting new introductions to the island after this first outbreak. In conclusion, a high diversity of SARS-CoV-2 isolates were found circulating in Venezuela, with predominance of the D614G mutation. The first small outbreak in Margarita Island seemed to be associated with a strain carrying a small deletion in the NSP1 protein, but these isolates do not seem to be responsible for the larger outbreak which started in July.


Assuntos
COVID-19/genética , Variação Genética , Genoma Viral , Filogenia , SARS-CoV-2/genética , Proteínas não Estruturais Virais/genética , Humanos , Domínios Proteicos , SARS-CoV-2/isolamento & purificação , Venezuela
4.
Rev. Inst. Nac. Hig ; 47(1-2): 18-24, 2016. tab, graf
Artigo em Espanhol | LILACS, LIVECS | ID: biblio-1005293

RESUMO

Los ensayos de cuantificación de ARN plasmáticos de VIH-1 son importantes para el control de pacientes infectados, así como el monitoreo de la respuesta a la terapia antirretroviral. Por lo tanto, los ensayos comerciales empleados para este propósito deben presentar buena correlación entre si, para dar lugar al manejo terapéutico apropiado. El objetivo del estudio consistió en correlacionar los resultados obtenidos mediante el ensayo de amplificación de señal (bDNA) y PCR en tiempo real (RT-PCR), ambas casas comerciales aprobadas por la FDA y con diferente diana de detección del VIH-1. La validación se realizó con 180 muestras clínicas de pacientes referidos al INHRR. Los resultados fueron comparados con la subpoblación de linfocitos TCD4+ determinados mediante citometría de flujo. El análisis estadístico se realizó empleando el coeficiente de regresión lineal de Pearson (R2) y el valor de contraste de hipótesis con una significancia del 95 %, usando el programa SPSS Statistics v10.0. Se observó una buena correlación entre los ensayos (R2=0.961, p<0.05), siendo la RTPCR más sensible. Las diferencias cuantitativas de carga viral entre las técnicas ensayadas fue menor de 0.5 log10 copias/ml para el 89% de las muestras, y >1 log10 copias/ml solo en dos pacientes, no indicando necesariamente cambio terapéutico. Adicionalmente, se encontró una correlación inversa entre los linfocitos TCD4+ y carga viral del VIH-1 medida por bDNA (R2= 0.20, p<0.05) y RT-PCR (R2= 0.15, p<0.05). Los ensayos evaluados mostraron que ambas técnicas puedes ser empleadas indistintamente para el control de los pacientes VIH positivo.


The assay for quantification of plasma HIV-1 RNA are important for the control of patients infected, as well as the monitoring of the response to antiretroviral therapy. Therefore, the commercial assays used for this purpose must submit good correlation between to give place to the appropriate therapeutic management. In this study, we correlate the results obtained through the testing of signal amplification (bDNA) and real-time PCR (RT-PCR), two comercial technical approved by the FDA and with different targets of detection HIV-1. The validation was carried out with 180 clinical samples of patients referred to the INHRR. The results were compared with the subpopulation of lymphocytes TCD4+ determined by flow cytometry. The statistical analysis was performed using the program SPSS Statistics v10. It was observed good correlation between the tests studied (R2=0.961, p<0.05), with RT-PCR more sensitive. The quantitative differences in viral load between the techniques tested was less than 0.5 log10 copies/ml for the 89% of the samples, and >1 log10 copies/ml in only two patients. Additionally, it was found an inverse correlation between lymphocytes TCD4+ and viral load of HIV-1, measured by bDNA (R2= 0.20, p<0.05) and RT-PCR (R2= 0.15, p<0.05). Therefore, these assays can be employed for the patient control HIV.


Assuntos
Humanos , Masculino , Feminino , Criança , Adulto , Idoso , Sorodiagnóstico da AIDS , Reação em Cadeia da Polimerase , HIV-1 , Carga Viral , Testes Sorológicos , Saúde Pública
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...