Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(11)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38893602

RESUMO

Incorrect scatter scaling of positron emission tomography (PET) images can lead to halo artifacts, quantitative bias, or reconstruction failure. Tail-fitted scatter scaling (TFSS) possesses performance limitations in multiple cases. This study aims to investigate a novel method for scatter scaling: maximum-likelihood scatter scaling (MLSS) in scenarios where TFSS tends to induce artifacts or are observed to cause reconstruction abortion. [68Ga]Ga-RGD PET scans of nine patients were included in cohort 1 in the scope of investigating the reduction of halo artifacts relative to the scatter estimation method. PET scans of 30 patients administrated with [68Ga]Ga-uPAR were included in cohort 2, used for an evaluation of the robustness of MLSS in cases where TFSS-integrated reconstructions are observed to fail. A visual inspection of MLSS-corrected images scored higher than TFSS-corrected reconstructions of cohort 1. The quantitative investigation near the bladder showed a relative difference in tracer uptake of up to 94.7%. A reconstruction of scans included in cohort 2 resulted in failure in 23 cases when TFSS was used. The lesion uptake values of cohort 2 showed no significant difference. MLSS is suggested as an alternative scatter-scaling method relative to TFSS with the aim of reducing halo artifacts and a robust reconstruction process.

2.
EJNMMI Phys ; 9(1): 55, 2022 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-35978211

RESUMO

BACKGROUND: Deep convolutional neural networks have demonstrated robust and reliable PET attenuation correction (AC) as an alternative to conventional AC methods in integrated PET/MRI systems. However, its whole-body implementation is still challenging due to anatomical variations and the limited MRI field of view. The aim of this study is to investigate a deep learning (DL) method to generate voxel-based synthetic CT (sCT) from Dixon MRI and use it as a whole-body solution for PET AC in a PET/MRI system. MATERIALS AND METHODS: Fifteen patients underwent PET/CT followed by PET/MRI with whole-body coverage from skull to feet. We performed MRI truncation correction and employed co-registered MRI and CT images for training and leave-one-out cross-validation. The network was pretrained with region-specific images. The accuracy of the AC maps and reconstructed PET images were assessed by performing a voxel-wise analysis and calculating the quantification error in SUV obtained using DL-based sCT (PETsCT) and a vendor-provided atlas-based method (PETAtlas), with the CT-based reconstruction (PETCT) serving as the reference. In addition, region-specific analysis was performed to compare the performances of the methods in brain, lung, liver, spine, pelvic bone, and aorta. RESULTS: Our DL-based method resulted in better estimates of AC maps with a mean absolute error of 62 HU, compared to 109 HU for the atlas-based method. We found an excellent voxel-by-voxel correlation between PETCT and PETsCT (R2 = 0.98). The absolute percentage difference in PET quantification for the entire image was 6.1% for PETsCT and 11.2% for PETAtlas. The regional analysis showed that the average errors and the variability for PETsCT were lower than PETAtlas in all regions. The largest errors were observed in the lung, while the smallest biases were observed in the brain and liver. CONCLUSIONS: Experimental results demonstrated that a DL approach for whole-body PET AC in PET/MRI is feasible and allows for more accurate results compared with conventional methods. Further evaluation using a larger training cohort is required for more accurate and robust performance.

3.
Eur J Hybrid Imaging ; 6(1): 7, 2022 Apr 05.
Artigo em Inglês | MEDLINE | ID: mdl-35378619

RESUMO

AIM: The concept of personalized medicine has brought increased awareness to the importance of inter- and intra-tumor heterogeneity for cancer treatment. The aim of this study was to explore simultaneous multi-parametric PET/MRI prior to chemoradiotherapy for cervical cancer for characterization of tumors and tumor heterogeneity. METHODS: Ten patients with histologically proven primary cervical cancer were examined with multi-parametric 68Ga-NODAGA-E[c(RGDyK)]2-PET/MRI for radiation treatment planning after diagnostic 18F-FDG-PET/CT. Standardized uptake values (SUV) of RGD and FDG, diffusion weighted MRI and the derived apparent diffusion coefficient (ADC), and pharmacokinetic maps obtained from dynamic contrast-enhanced MRI with the Tofts model (iAUC60, Ktrans, ve, and kep) were included in the analysis. The spatial relation between functional imaging parameters in tumors was examined by a correlation analysis and joint histograms at the voxel level. The ability of multi-parametric imaging to identify tumor tissue classes was explored using an unsupervised 3D Gaussian mixture model-based cluster analysis. RESULTS: Functional MRI and PET of cervical cancers appeared heterogeneous both between patients and spatially within the tumors, and the relations between parameters varied strongly within the patient cohort. The strongest spatial correlation was observed between FDG uptake and ADC (median r = - 0.7). There was moderate voxel-wise correlation between RGD and FDG uptake, and weak correlations between all other modalities. Distinct relations between the ADC and RGD uptake as well as the ADC and FDG uptake were apparent in joint histograms. A cluster analysis using the combination of ADC, FDG and RGD uptake suggested tissue classes which could potentially relate to tumor sub-volumes. CONCLUSION: A multi-parametric PET/MRI examination of patients with cervical cancer integrated with treatment planning and including estimation of angiogenesis and glucose metabolism as well as MRI diffusion and perfusion parameters is feasible. A combined analysis of functional imaging parameters indicates a potential of multi-parametric PET/MRI to contribute to a better characterization of tumor heterogeneity than the modalities alone. However, the study is based on small patient numbers and further studies are needed prior to the future design of individually adapted treatment approaches based on multi-parametric functional imaging.

4.
Acta Oncol ; 60(8): 1045-1053, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34107847

RESUMO

BACKGROUND: Radiotherapy (RT) planning for cervical cancer patients entails the acquisition of both Computed Tomography (CT) and Magnetic Resonance Imaging (MRI). Further, molecular imaging by Positron Emission Tomography (PET) could contribute to target volume delineation as well as treatment response monitoring. The objective of this study was to investigate the feasibility of a PET/MRI-only RT planning workflow of patients with cervical cancer. This includes attenuation correction (AC) of MRI hardware and dedicated positioning equipment as well as evaluating MRI-derived synthetic CT (sCT) of the pelvic region for positioning verification and dose calculation to enable a PET/MRI-only setup. MATERIAL AND METHODS: 16 patients underwent PET/MRI using a dedicated RT setup after the routine CT (or PET/CT), including eight pilot patients and eight cervical cancer patients who were subsequently referred for RT. Data from 18 patients with gynecological cancer were added for training a deep convolutional neural network to generate sCT from Dixon MRI. The mean absolute difference between the dose distributions calculated on sCT and a reference CT was measured in the RT target volume and organs at risk. PET AC by sCT and a reference CT were compared in the tumor volume. RESULTS: All patients completed the examination. sCT was inferred for each patient in less than 5 s. The dosimetric analysis of the sCT-based dose planning showed a mean absolute error (MAE) of 0.17 ± 0.12 Gy inside the planning target volumes (PTV). PET images reconstructed with sCT and CT had no significant difference in quantification for all patients. CONCLUSIONS: These results suggest that multiparametric PET/MRI can be successfully integrated as a one-stop-shop in the RT workflow of patients with cervical cancer.


Assuntos
Neoplasias do Colo do Útero , Feminino , Humanos , Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Tomografia por Emissão de Pósitrons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Tomografia Computadorizada por Raios X , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...