Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS Med ; 15(7): e1002599, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29969461

RESUMO

BACKGROUND: Climate change negatively impacts human health through heat stress and exposure to worsened air pollution, amongst other pathways. Indoor use of air conditioning can be an effective strategy to reduce heat exposure. However, increased air conditioning use increases emissions of air pollutants from power plants, in turn worsening air quality and human health impacts. We used an interdisciplinary linked model system to quantify the impacts of heat-driven adaptation through building cooling demand on air-quality-related health outcomes in a representative mid-century climate scenario. METHODS AND FINDINGS: We used a modeling system that included downscaling historical and future climate data with the Weather Research and Forecasting (WRF) model, simulating building electricity demand using the Regional Building Energy Simulation System (RBESS), simulating power sector production and emissions using MyPower, simulating ambient air quality using the Community Multiscale Air Quality (CMAQ) model, and calculating the incidence of adverse health outcomes using the Environmental Benefits Mapping and Analysis Program (BenMAP). We performed simulations for a representative present-day climate scenario and 2 representative mid-century climate scenarios, with and without exacerbated power sector emissions from adaptation in building energy use. We find that by mid-century, climate change alone can increase fine particulate matter (PM2.5) concentrations by 58.6% (2.50 µg/m3) and ozone (O3) by 14.9% (8.06 parts per billion by volume [ppbv]) for the month of July. A larger change is found when comparing the present day to the combined impact of climate change and increased building energy use, where PM2.5 increases 61.1% (2.60 µg/m3) and O3 increases 15.9% (8.64 ppbv). Therefore, 3.8% of the total increase in PM2.5 and 6.7% of the total increase in O3 is attributable to adaptive behavior (extra air conditioning use). Health impacts assessment finds that for a mid-century climate change scenario (with adaptation), annual PM2.5-related adult mortality increases by 13,547 deaths (14 concentration-response functions with mean incidence range of 1,320 to 26,481, approximately US$126 billion cost) and annual O3-related adult mortality increases by 3,514 deaths (3 functions with mean incidence range of 2,175 to 4,920, approximately US$32.5 billion cost), calculated as a 3-month summer estimate based on July modeling. Air conditioning adaptation accounts for 654 (range of 87 to 1,245) of the PM2.5-related deaths (approximately US$6 billion cost, a 4.8% increase above climate change impacts alone) and 315 (range of 198 to 438) of the O3-related deaths (approximately US$3 billion cost, an 8.7% increase above climate change impacts alone). Limitations of this study include modeling only a single month, based on 1 model-year of future climate simulations. As a result, we do not project the future, but rather describe the potential damages from interactions arising between climate, energy use, and air quality. CONCLUSIONS: This study examines the contribution of future air-pollution-related health damages that are caused by the power sector through heat-driven air conditioning adaptation in buildings. Results show that without intervention, approximately 5%-9% of exacerbated air-pollution-related mortality will be due to increases in power sector emissions from heat-driven building electricity demand. This analysis highlights the need for cleaner energy sources, energy efficiency, and energy conservation to meet our growing dependence on building cooling systems and simultaneously mitigate climate change.


Assuntos
Ar Condicionado/efeitos adversos , Poluentes Atmosféricos/efeitos adversos , Poluição do Ar , Exposição Ambiental/efeitos adversos , Arquitetura de Instituições de Saúde , Aquecimento Global , Material Particulado/efeitos adversos , Temperatura , Adulto , Idoso , Idoso de 80 Anos ou mais , Ar Condicionado/economia , Poluição do Ar/economia , Causas de Morte , Simulação por Computador , Monitoramento Ambiental/métodos , Arquitetura de Instituições de Saúde/economia , Feminino , Aquecimento Global/economia , Aquecimento Global/mortalidade , Nível de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Análise Numérica Assistida por Computador , Medição de Risco , Fatores de Risco , Fatores de Tempo , Estados Unidos
2.
Environ Sci Technol ; 51(10): 5838-5846, 2017 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-28466642

RESUMO

Past studies have established strong connections between meteorology and air quality, via chemistry, transport, and natural emissions. A less understood linkage between weather and air quality is the temperature-dependence of emissions from electricity generating units (EGUs), associated with high electricity demand to support building cooling on hot days. This study quantifies the relationship between ambient surface temperatures and EGU air emissions (CO2, SO2, and NOX) using historical data. We find that EGUs in the Eastern U.S. region from 2007 to 2012 exhibited a 3.87% ± 0.41% increase in electricity generation per °C increase during summer months. This is associated with a 3.35%/°C ± 0.50%/°C increase in SO2 emissions, a 3.60%/°C ± 0.49%/°C increase in NOX emissions, and a 3.32%/°C ± 0.36%/°C increase in CO2 emissions. Sensitivities vary by year and by pollutant, with SO2 both the highest sensitivity (5.04% in 2012) and lowest sensitivity (2.19% in 2007) in terms of a regional average. Texas displays 2007-2012 sensitivities of 2.34%/°C ± 0.28%/°C for generation, 0.91%/°C ± 0.25%/°C for SO2 emissions, 2.15%/°C ± 0.29%/°C for NOX emissions, and 1.78%/°C ± 0.22%/°C for CO2 emissions. These results suggest demand-side and supply side technological improvements and fuel choice could play an important role in cost-effective reduction of carbon emissions and air pollution.


Assuntos
Poluentes Atmosféricos/análise , Centrais Elétricas , Temperatura , Poluição do Ar , Texas , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...