Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Chest ; 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38013161

RESUMO

BACKGROUND: Airway mucus plugs are frequently identified on CT scans of patients with COPD with a smoking history without mucus-related symptoms (ie, cough, phlegm [silent mucus plugs]). RESEARCH QUESTION: In patients with COPD, what are the risk and protective factors associated with silent airway mucus plugs? Are silent mucus plugs associated with functional, structural, and clinical measures of disease? STUDY DESIGN AND METHODS: We identified mucus plugs on chest CT scans of participants with COPD from the COPDGene study. The mucus plug score was defined as the number of pulmonary segments with mucus plugs, ranging from 0 to 18, and categorized into three groups (0, 1-2, and ≥ 3). We determined risk and protective factors for silent mucus plugs and the associations of silent mucus plugs with measures of disease severity using multivariable linear and logistic regression models. RESULTS: Of 4,363 participants with COPD, 1,739 had no cough or phlegm. Among the 1,739 participants, 627 (36%) had airway mucus plugs identified on CT scan. Risk factors of silent mucus plugs (compared with symptomatic mucus plugs) were older age (OR, 1.02), female sex (OR, 1.40), and Black race (OR, 1.93) (all P values < .01). Among those without cough or phlegm, silent mucus plugs (vs absence of mucus plugs) were associated with worse 6-min walk distance, worse resting arterial oxygen saturation, worse FEV1 % predicted, greater emphysema, thicker airway walls, and higher odds of severe exacerbation in the past year in adjusted models. INTERPRETATION: Mucus plugs are common in patients with COPD without mucus-related symptoms. Silent mucus plugs are associated with worse functional, structural, and clinical measures of disease. CT scan-identified mucus plugs can complement the evaluation of patients with COPD.

2.
JAMA ; 329(21): 1832-1839, 2023 06 06.
Artigo em Inglês | MEDLINE | ID: mdl-37210745

RESUMO

Importance: Airway mucus plugs are common in patients with chronic obstructive pulmonary disease (COPD); however, the association of airway mucus plugging and mortality in patients with COPD is unknown. Objective: To determine whether airway mucus plugs identified on chest computed tomography (CT) were associated with increased all-cause mortality. Design, Setting, and Participants: Observational retrospective analysis of prospectively collected data of patients with a diagnosis of COPD in the Genetic Epidemiology of COPD cohort. Participants were non-Hispanic Black or White individuals, aged 45 to 80 years, who smoked at least 10 pack-years. Participants were enrolled at 21 centers across the US between November 2007 and April 2011 and were followed up through August 31, 2022. Exposures: Mucus plugs that completely occluded airways on chest CT scans, identified in medium- to large-sized airways (ie, approximately 2- to 10-mm lumen diameter) and categorized as affecting 0, 1 to 2, or 3 or more lung segments. Main Outcomes and Measures: The primary outcome was all-cause mortality, assessed with proportional hazard regression analysis. Models were adjusted for age, sex, race and ethnicity, body mass index, pack-years smoked, current smoking status, forced expiratory volume in the first second of expiration, and CT measures of emphysema and airway disease. Results: Among the 4483 participants with COPD, 4363 were included in the primary analysis (median age, 63 years [IQR, 57-70 years]; 44% were women). A total of 2585 (59.3%), 953 (21.8%), and 825 (18.9%) participants had mucus plugs in 0, 1 to 2, and 3 or more lung segments, respectively. During a median 9.5-year follow-up, 1769 participants (40.6%) died. The mortality rates were 34.0% (95% CI, 32.2%-35.8%), 46.7% (95% CI, 43.5%-49.9%), and 54.1% (95% CI, 50.7%-57.4%) in participants who had mucus plugs in 0, 1 to 2, and 3 or more lung segments, respectively. The presence of mucus plugs in 1 to 2 vs 0 and 3 or more vs 0 lung segments was associated with an adjusted hazard ratio of death of 1.15 (95% CI, 1.02-1.29) and 1.24 (95% CI, 1.10-1.41), respectively. Conclusions and Relevance: In participants with COPD, the presence of mucus plugs that obstructed medium- to large-sized airways was associated with higher all-cause mortality compared with patients without mucus plugging on chest CT scans.


Assuntos
Obstrução das Vias Respiratórias , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Obstrução das Vias Respiratórias/diagnóstico por imagem , Obstrução das Vias Respiratórias/etiologia , Obstrução das Vias Respiratórias/mortalidade , Volume Expiratório Forçado , Pulmão , Muco , Doença Pulmonar Obstrutiva Crônica/etiologia , Doença Pulmonar Obstrutiva Crônica/mortalidade , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Fumar Cigarros/efeitos adversos
3.
Radiol Cardiothorac Imaging ; 4(5): e220077, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36339061

RESUMO

The Warden procedure is one of the most common techniques for surgical correction of partial anomalous pulmonary venous return (PAPVR), involving transection and reanastomosis of the superior vena cava (SVC) to the right atrial appendage and baffling of the anomalous pulmonary veins through the atrial septal defect. While the procedure is typically well-tolerated in pediatric patients, adult patients requiring surgical correction of PAPVR are uncommon. The authors report a case of a 33-year-old woman who developed SVC syndrome as a delayed complication of the Warden procedure. Keywords: Cardiac, Congenital, Complications © RSNA, 2022.

4.
J Cardiol Cases ; 25(2): 68-71, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35079300

RESUMO

Cor triatriatum dexter is an extremely rare congenital heart defect and cause of hypoxia in adults. We describe a case of cor triatriatum dexter discovered incidentally due to an iatrogenic atrial septal defect. The cor triatriatum dexter resolved with balloon dilation - a novel technique to manage this rare clinical condition. .

5.
J Digit Imaging ; 34(3): 750-759, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33885992

RESUMO

Digital images used in the field of ophthalmology are among the most important methods for automatic detection of certain eye diseases. These processes include image enhancement as a primary step to assist optometrists in identifying diseases. Therefore, many algorithms and methods have been developed for the enhancement of retinal fundus images, which may experience challenges that typically accompany enhancement processes, such as artificial borders and dim lighting that mask image details. To eliminate these problems, a new algorithm is proposed in this paper based on separating colour images into three channels (red, green, and blue). The green channel is passed through a Wiener filter and reinforced using the CLAHE technique before merging with the original red and blue channels. Reducing the green channel noise with this approach is proven effective over the other colour channels. Results from the Contrast Improvement Index (CII) and linear index of fuzziness (r) test indicate the success of the proposed algorithm compared with alternate algorithms in the application of improving blood vessel imagery and other details within ten test fundus images selected from the DRIVER database.


Assuntos
Algoritmos , Aumento da Imagem , Cor , Bases de Dados Factuais , Fundo de Olho , Humanos , Vasos Retinianos/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...