Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 409(24): 5619-5629, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28741108

RESUMO

An online two-dimensional (2D) liquid chromatography/2D gas chromatography system with two mass-selective detectors has been developed on the basis of a previous system with two flame ionization detectors. The method translation involved the change of carrier gas from hydrogen to helium, column dimension and detectors. The 2D system with two mass-selective detectors was validated with use of polycyclic aromatic hydrocarbon (PAH) standards and two standard reference materials from air and diesel exhaust. Furthermore, the system was applied to a real sample, wood smoke particulates. The PAH values determined correlated well with the previous data and those from the National Institute of Standards and Technology. The system enhanced the benefits of the previous system, which were limited by the low detectability and lack of mass selectivity. This study shows an automated 2D system that is valid for PAH analysis of complex environmental samples directly from crude extracts. Graphical Abstract Schematic illustration showing on-line clean-up, separation and detection using 2D-LC/2D-GC/MS.

2.
Environ Health ; 16(1): 61, 2017 06 23.
Artigo em Inglês | MEDLINE | ID: mdl-28641573

RESUMO

BACKGROUND: Polycyclic aromatic hydrocarbons (PAHs) are the main toxic compounds in natural bitumen, a fossil material used by modern and ancient societies around the world. The adverse health effects of PAHs on modern humans are well established, but their health impacts on past populations are unclear. It has previously been suggested that a prehistoric health decline among the native people living on the California Channel Islands may have been related to PAH exposure. Here, we assess the potential health risks of PAH exposure from the use and manufacture of bitumen-coated water bottles by ancient California Indian societies. METHODS: We replicated prehistoric bitumen-coated water bottles with traditional materials and techniques of California Indians, based on ethnographic and archaeological evidence. In order to estimate PAH exposure related to water bottle manufacture and use, we conducted controlled experiments to measure PAH contamination 1) in air during the manufacturing process and 2) in water and olive oil stored in a completed bottle for varying periods of time. Samples were analyzed with gas chromatography/mass spectrometry (GC/MS) for concentrations of the 16 PAHs identified by the US Environmental Protection Agency (EPA) as priority pollutants. RESULTS: Eight PAHs were detected in concentrations of 1-10 µg/m3 in air during bottle production and 50-900 ng/L in water after 2 months of storage, ranging from two-ring (naphthalene and methylnaphthalene) to four-ring (fluoranthene) molecules. All 16 PAHs analyzed were detected in olive oil after 2 days (2 to 35 µg/kg), 2 weeks (3 to 66 µg/kg), and 2 months (5 to 140 µg/kg) of storage. CONCLUSIONS: For ancient California Indians, water stored in bitumen-coated water bottles was not a significant source of PAH exposure, but production of such bottles could have resulted in harmful airborne PAH exposure.


Assuntos
Poluentes Atmosféricos/história , Água Potável/análise , Exposição Ambiental/história , Hidrocarbonetos , Hidrocarbonetos Policíclicos Aromáticos/história , Grupos Populacionais/história , Poluentes Químicos da Água/história , Poluentes Atmosféricos/análise , California , Exposição Ambiental/análise , História Antiga , Humanos , Hidrocarbonetos Policíclicos Aromáticos/análise , Medição de Risco , Poluentes Químicos da Água/análise
3.
Anal Bioanal Chem ; 407(2): 427-38, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25395203

RESUMO

The objective of this study was to develop a novel analytical chemistry method, comprised of a coupled high-performance liquid chromatography-gas chromatography/mass spectrometry system (LC-GC/MS) with low detection limits and high selectivity, for the identification and determination of oxygenated polycyclic aromatic hydrocarbons (OPAHs) and polycyclic aromatic hydrocarbons (PAHs) in urban air and diesel particulate matter. The linear range of the four OPAHs, which include 9,10-anthraquinone, 4H-cyclopenta[def]phenanthrene-4-one, benzanthrone, and 7,12-benz[a]anthraquinone, was 0.7 pg-43.3 ng with limits of detection (LODs) and limits of quantification (LOQs) on the order of 0.2-0.8 and 0.7-1.3 pg, respectively. The LODs in this study are generally lower than values reported in the literature, which can be explained by using large-volume injection. The recoveries of the OPAHs spiked onto glass fiber filters using two different pressurized liquid extraction (PLE) methods were in the ranges of 84-107 and 67-110 %, respectively. The analytical protocols were validated using the following National Institute of Standards and Technology standard reference materials: SRM 1649a (Urban Dust), SRM 1650b (Diesel Particulate Matter), and SRM 2975 (Diesel Particulate Matter, Industrial Forklift). The measured mass fractions of the OPAHs in the standard reference materials (SRMs) in this present study are higher than the values from the literature, except for benzanthrone in SRM 1649a (Urban Dust). In addition to the OPAHs, 44 PAHs could be detected and quantified from the same particulate extract used in this protocol. Using data from the literature and applying a two-sided t test at the 5 % level using Bonferroni correction, significant differences were found between the tested PLE methods for individual PAHs. However, the measured mass fractions of the PAHs were comparable, similar to, or higher than those previously reported in the literature.


Assuntos
Cromatografia Líquida/métodos , Poeira/análise , Cromatografia Gasosa-Espectrometria de Massas/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Emissões de Veículos/análise , Poluentes Atmosféricos/análise , Antraquinonas/análise , Benzo(a)Antracenos/análise , Calibragem , Fracionamento Químico/métodos , Cromatografia Líquida/normas , Cromatografia Gasosa-Espectrometria de Massas/normas , Gonanos/análise , Limite de Detecção , Oxigênio/química , Material Particulado/análise , Hidrocarbonetos Policíclicos Aromáticos/química , Padrões de Referência , Reprodutibilidade dos Testes , Urbanização
4.
Anal Bioanal Chem ; 405(25): 8215-22, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23892881

RESUMO

A multidimensional, on-line coupled liquid chromatographic/gas chromatographic system was developed for the quantification of polycyclic aromatic hydrocarbons (PAHs). A two-dimensional liquid chromatographic system (2D-liquid chromatography (LC)), with three columns having different selectivities, was connected on-line to a two-dimensional gas chromatographic system (2D-gas chromatography (GC)). Samples were cleaned up by combining normal elution and column back-flush of the LC columns to selectively remove matrix constituents and isolate well-defined, PAH enriched fractions. Using this system, the sequential removal of polar, mono/diaromatic, olefinic and alkane compounds from crude extracts was achieved. The LC/GC coupling was performed using a fused silica transfer line into a programmable temperature vaporizer (PTV) GC injector. Using the PTV in the solvent vent mode, excess solvent was removed and the enriched PAH sample extract was injected into the GC. The 2D-GC setup consisted of two capillary columns with different stationary phase selectivities. Heart-cutting of selected PAH compounds in the first GC column (first dimension) and transfer of these to the second GC column (second dimension) increased the baseline resolutions of closely eluting PAHs. The on-line system was validated using the standard reference materials SRM 1649a (urban dust) and SRM 1975 (diesel particulate extract). The PAH concentrations measured were comparable to the certified values and the fully automated LC/GC system performed the clean-up, separation and detection of PAHs in 16 extracts in less than 24 h. The multidimensional, on-line 2D-LC/2D-GC system eliminated manual handling of the sample extracts and minimised the risk of sample loss and contamination, while increasing accuracy and precision.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...