Radiat Oncol ; 13(1): 88, 2018 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-29739431

RESUMO

BACKGROUND: The aim of this study was to investigate the dosimetric quality in volumetric modulated arc therapy (VMAT) plans with optimal collimator angles that can represent the outline of multiple brain targets. METHODS: Twenty patients with multiple target volumes in the brain cases were selected retrospectively. To better represent the outline of the multiple brain targets, four conformal arc plans were generated for each patient using one full arc with four collimator settings. The optimal collimator angles calculated from the integrated multi-leaf collimator (MLC) aperture that had the smallest aperture size for certain collimator settings of the conformal arc plan were selected. VMAT plans with the optimal collimator angles with angular sections of 40° and 60° (Colli-VMAT (40°), Colli-VMAT (60°)) were generated, followed by evaluation of field sizes, dose-volumetric parameters and total monitor units (MUs). RESULTS: Patient-averaged values of field sizes for Colli-VMAT (40°) (111.5 cm2) were lowest and 1.3 times smaller than those for Std-VMAT (143.6 cm2). Colli-VMAT plans improved sparing of most normal organs but for brain stem and left parotid gland. For the total MUs, the averaged values obtained with the Colli-VMAT (40°) (390 ± 148 MU) were smaller than those obtained with the Std-VMAT (472 ± 235 MU). CONCLUSIONS: The Colli-VMAT plans with smaller angular sections could be suitable in the clinic for multiple brain targets as well as for irregularly shaped targets. Determination of the optimal collimator rotation generally showed good normal tissue sparing and MU reduction for multiple brain targets.


Assuntos
Neoplasias Encefálicas/radioterapia , Encéfalo/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Encéfalo/efeitos da radiação , Humanos , Prognóstico , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Estudos Retrospectivos , Rotação
2.
PLoS One ; 12(4): e0174924, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28384262

RESUMO

PURPOSE: To calculate an optimal collimator angle at each of sectional arcs in a full-arc volumetric modulated arc therapy (VMAT) plan and evaluate dosimetric quality of these VMAT plans comparing full-arc VMAT plans with a fixed collimator angle. METHODS: Seventeen patients who had irregularly-shaped target in abdominal, head and neck, and chest cases were selected retrospectively. To calculate an optimal collimator angle at each of sectional arcs in VMAT, integrated MLC apertures which could cover all shapes of target determined by beam's-eye view (BEV) within angular sections were obtained for each VMAT plan. The angular sections were 40°, 60°, 90° and 120°. When the collimator settings were rotated at intervals of 2°, we obtained the optimal collimator angle to minimize area size difference between the integrated MLC aperture and collimator settings with 5 mm-margins to the integrated MLC aperture. The VMAT plans with the optimal collimator angles (Colli-VMAT) were generated in the EclipseTM. For comparison purposes, one full-arc VMAT plans with a fixed collimator angles (Std-VMAT) were generated. The dose-volumetric parameters and total MUs were evaluated. RESULTS: The mean dose-volumetric parameters for target volume of Colli-VMAT were comparable to Std-VMAT. Colli-VMAT improved sparing of most normal organs but for brain stem, compared to Std-VMAT for all cases. There were decreasing tendencies in mean total MUs with decreasing angular section. The mean total MUs for Colli-VMAT with the angular section of 40° (434 ± 95 MU, 317 ± 81 MU, and 371 ± 43 MU for abdominal, head and neck, and chest cases, respectively) were lower than those for Std-VMAT (654 ± 182 MU, 517 ± 116 MU, and 533 ± 25 MU, respectively). CONCLUSIONS: For an irregularly-shaped target, Colli-VMAT with the angular section of 40° reduced total MUs and improved sparing of normal organs, compared to Std-VMAT.


Assuntos
Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Planejamento da Radioterapia Assistida por Computador/instrumentação
3.
Radiat Oncol ; 9: 197, 2014 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-25194217

RESUMO

BACKGROUND: In this study, dosimetric aspects of TSEI consisting of a 4 MeV beam with no spoiler were investigated in comparison to a nominal 6 MeV beam with spoiler, and the potential for clinical applications was evaluated. METHODS: The TSEI technique is based on the Stanford technique, which utilizes a beam configuration of six-dual fields. MOSFETs were used to measure the optimal gantry angle, profile uniformity, and absolute dose at the calibration point. The depth dose curve of the central axis was measured in the treatment plane using EBT2 film. Photon contamination was measured as the dose at 5 cm depth in a solid water phantom relative to the maximum dose using a parallel plate ion chamber. A MOSFET dosimeter placed on the surface of a humanoid phantom, and EBT2 films inserted into a humanoid phantom were used to verify the TSEI commissioning. RESULTS: Dosimetric aspects of the 4 MeV TSEI beam, such as profile uniformity (±10%) and relative photon contamination (<0.001%), were comparable to those of a 6 MeV TSEI beam. The relative depth dose of the 4 MeV electrons was 81.4% at the surface and 100% at 0.4 cm. For the 6 MeV electrons, the relative depth dose was 93.4% at the surface and 100% from 0.2 cm to 0.4 cm. The calculated B-factor of the 4 MeV TSEI beam was 1.55, and 1.53 for the 6 MeV TSEI. 80% of the prescribed dose was obtained at 0.22 cm depth for the 4 MeV TSEI beam and 0.53 cm for the 6 MeV TSEI beam in the humanoid phantom measurement. CONCLUSIONS: The suggested 4 MeV beam for TSEI could be applied to shallow depth skin diseases and to electron boost as second treatment course.