Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-31388292

RESUMO

This paper presents a high-resolution magnetic field mapping system in development that is capable of collecting spatial magnetic field data for NMR magnets. An NMR probe was designed and built with a resonant frequency of 5.73 MHz. The measured Q-factor of the NMR probe is ~191 with a half-power bandwidth in the range of 5.72-5.75 MHz. An RF continuous-wave technique with magnetic field modulation was utilized to detect the power dispersion of water molecules. The zero-crossing frequency of the NMR dispersion signal corresponds to the magnetic field at the center of the water sample. An embedded system was developed to sweep the frequency and record the reflected RF power simultaneously. A numerically controlled digital oscillator is able to provide a precise frequency step as small as 0.02 Hz, which is equivalent to 4.7 e-7 mT for hydrogen atoms. An RF preamplifier was built to supply up to 4 W of RF power to a bidirectional coupler. The coupler supplies RF power to the NMR probe and channels reflect the RF power back to the detection circuit, which detects the reflected RF power from the NMR probe during the frequency sweep. The homogeneity of an NMR magnet can be determined by magnetic field data.

2.
IEEE Trans Appl Supercond ; 20(3): 1037-1040, 2010 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20585463

RESUMO

This paper presents experimental and analytical results of trapped field characteristics of a stack of square YBCO thin film plates for compact NMR magnets. Each YBCO plate, 40 mm × 40 mm × 0.08 mm, has a 25-mm diameter hole at its center. A total of 500 stacked plates were used to build a 40-mm long magnet. Its trapped field, in a bath of liquid nitrogen, was measured for spatial field distribution and temporal stability. Comparison of measured and analytical results is presented: the effects on trapped field characteristics of the unsaturated nickel substrate and the non-uniform current distribution in the YBCO plate are discussed.

3.
IEEE Trans Appl Supercond ; 19(3): 2281-2284, 2009 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20407595

RESUMO

This paper addresses adverse effects of dimensional uncertainties of an HTS insert assembled with double-pancake coils on spatial field homogeneity. Each DP coil was wound with Bi2223 tapes having dimensional tolerances larger than one order of magnitude of those accepted for LTS wires used in conventional NMR magnets. The paper presents: 1) dimensional variations measured in two LTS/HTS NMR magnets, 350 MHz (LH350) and 700 MHz (LH700), both built and operated at the Francis Bitter Magnet Laboratory; and 2) an analytical technique and its application to elucidate the field impurities measured with the two LTS/HTS magnets. Field impurities computed with the analytical model and those measured with the two LTS/HTS magnets agree quite well, demonstrating that this analytical technique is applicable to design a DP-assembled HTS insert with an improved field homogeneity for a high-field LTS/HTS NMR magnet.

4.
IEEE Trans Appl Supercond ; 19(3): 2285-2288, 2009 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-20383282

RESUMO

This paper reports results, experimental and analytical, of the nonlinear behavior of a shim coil in the presence of an HTS coil assembled with double-pancake (DP) HTS-tape coils. The experimental results are from: 1) operation of a 700 MHz LTS/HTS NMR magnet (LH700) consisting of a 600 MHz LTS NMR magnet (L600) equipped with superconducting shim coils and a 100 MHz DP-assembled HTS insert (H100) and; 2) an experiment with a room-temperature (RT) Z1 shim coil coupled to a 50 MHz DP-as-sembled HTS insert (H50). A field mapping theory with a harmonic analysis is applied to interpret both results. Based on experimental results and analyses, we conclude that the screening-current-induced field (SCF) generated by a DP-assembled HTS insert is primarily responsible for the nonlinear behavior, including strength degradation, of a shim coil.

5.
IEEE Trans Appl Supercond ; 19(3): 2269-2272, 2009 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-20401187

RESUMO

This paper presents experimental and simulation results of a screening current induced magnetic field (SCF) in a high temperature superconductor (HTS) insert that constitutes a low-/high-temperature superconductor (LTS/HTS) NMR magnet. In this experiment, the HTS insert, a stack of 50 double-pancake coils, each wound with Bi2223 tape, was operated at 77 K. A screening current was induced in the HTS insert by three magnetic field sources: 1) a self field from the HTS insert; 2) an external field from a 5-T background magnet; and 3) combinations of 1) and 2). For each field excitation, which induced an SCF, its axial field distribution and temporal variations were measured and compared with simulation results based on the critical state model. Agreement on field profile between experiment and simulation is satisfactory but more work is needed to make the simulation useful for designing shim coils that will cancel the SCF.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...