Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Foot Ankle Res ; 8: 5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25741384

RESUMO

BACKGROUND: Non-invasive evaluation of in-shoe foot motion has traditionally been difficult. Recently a novel 'stretch-sensor' was proposed as an easy and reliable method to measure dynamic foot (navicular) motion. Further validation of this method is needed to determine how different gait analysis protocols affect dynamic navicular motion. METHODS: Potential differences in magnitude and peak velocity of navicular motion using the 'stretch sensor' between (i) barefoot and shod conditions; (ii) overground and treadmill gait; and/or (iii) running and walking were evaluated in 26 healthy participants. Comparisons were made using paired t-tests. RESULTS: Magnitude and velocity of navicular motion was not different between barefoot and shod walking on the treadmill. Compared to walking, velocity of navicular motion during running was 59% and 210% higher over-ground (p < 0.0001) and on a treadmill (p < 0.0001) respectively, and magnitude of navicular motion was 23% higher during over-ground running compared to over-ground walking (p = 0.02). Compared to over-ground, magnitude of navicular motion on a treadmill was 21% and 16% greater during walking (p = 0.0004) and running (p = 0003) respectively. Additionally, maximal velocity of navicular motion during treadmill walking was 48% less than walking over-ground (p < 0.0001). CONCLUSION: The presence of footwear has minimal impact on navicular motion during walking. Differences in navicular motion between walking and running, and treadmill and over-ground gait highlight the importance of task specificity during gait analysis. Task specificity should be considered during design of future research trials and in clinical practice when measuring navicular motion.

2.
Br J Sports Med ; 48(8): 724-8, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23467964

RESUMO

OBJECTIVE: To investigate if a new stretch sensor attached to an elastic exercise band can assist health professionals in evaluating adherence to home exercises. More specifically, the study investigated whether health professionals can differentiate elastic band exercises performed as prescribed, from exercises not performed as prescribed. METHODS: 10 participants performed four different shoulder-abduction exercises in two rounds (80 exercise scenarios in total). The scenarios were (1) low contraction speed, full range of motion (0-90°), (2) high contraction speed, full range of motion (0-90°), (3) low contraction speed, diminished range of motion (0-45°) and (4) unsystematic pull of the elastic exercise band. Stretch-sensor readings from each participant were recorded and presented randomly to the raters. Two raters were asked to differentiate between unsystematic pull (scenario 4), from shoulder abduction strength exercises (scenarios 1-3). The next two raters were asked to identify the four different exercise scenarios (scenarios 1-4). RESULTS: The first two raters were able to differentiate between unsystematic pull (scenario 4) from shoulder abduction strength exercises (scenarios 1-3). They made no errors (100% success rate). The second two raters were both able to identify each of the 80 scenarios (scenarios 1-4). They too made no errors (100% success rate). CONCLUSIONS: The stretch-sensor readings from the elastic exercise band allow health professionals to quantify whether strength-exercises have been performed as prescribed. These findings have great implications for future clinical practice and research where home exercises are the drugs-of-choice, as they enable clinicians and researchers to measure the exact adherence and quality of the prescribed exercises.


Assuntos
Serviços de Assistência Domiciliar , Exercícios de Alongamento Muscular/instrumentação , Cooperação do Paciente , Adulto , Elasticidade/fisiologia , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Monitorização Ambulatorial/instrumentação , Contração Muscular/fisiologia , Variações Dependentes do Observador , Fisioterapeutas , Amplitude de Movimento Articular/fisiologia , Medicina Esportiva
3.
Telemed J E Health ; 19(11): 826-33, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23631589

RESUMO

BACKGROUND: Patients with hypertension or receiving blood pressure (BP)-lowering treatment are often required to self-measure their BP in a dedicated self-measurement room before consultation. Current praxis does not guarantee valid measurements, possibly leading to misdiagnoses or inappropriate antihypertensive medication. The aim of this study was to investigate patients' ability to correctly self-report and follow recommendations. PATIENTS AND METHODS: We used a context-aware system to gather information on BP measurements and relevant context parameters. Patients were not informed that the system automatically collected behavior data and were instructed to self-report their measurements on a paper sheet as usual. We then compared the automatically recorded data with the self-reported data in order to detect any nonadherent reporting behavior. Also, we investigated the patients' ability to adhere to the measurement recommendations. RESULTS: We found that (1) a third of all 113 participating patients failed to self-report measured BP data correctly and (2) none of the 642 measurements obtained adhered fully to the recommendations. CONCLUSIONS: Results indicate that context-aware technology may be useful for accurately modeling aspects of nonadherent patient behavior. This may be used to inform staff of the validity of the measurement and pinpoint patients in need of additional training or to design better aids to assist the patients. The developed system is generally applicable to other self-measurement environments, including the home setting and remote outpatient clinics, as it is built using telemedicine technology and thus well suited for remote monitoring and diagnosis.


Assuntos
Anti-Hipertensivos/uso terapêutico , Monitorização Ambulatorial da Pressão Arterial/normas , Hipertensão/tratamento farmacológico , Cooperação do Paciente , Autorrelato , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
4.
Sensors (Basel) ; 12(9): 11697-711, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23112678

RESUMO

Analysis of foot movement is essential in the treatment and prevention of foot-related disorders. Measuring the in-shoe foot movement during everyday activities, such as sports, has the potential to become an important diagnostic tool in clinical practice. The current paper describes the development of a thin, flexible and robust capacitive strain sensor for the in-shoe measurement of the navicular drop. The navicular drop is a well-recognized measure of foot movement. The position of the strain sensor on the foot was analyzed to determine the optimal points of attachment. The sensor was evaluated against a state-of-the-art video-based system that tracks reflective markers on the bare foot. Preliminary experimental results show that the developed strain sensor is able to measure navicular drop on the bare foot with an accuracy on par with the video-based system and with a high reproducibility. Temporal comparison of video-based, barefoot and in-shoe measurements indicate that the developed sensor measures the navicular drop accurately in shoes and can be used without any discomfort for the user.


Assuntos
Marcha/fisiologia , Movimento/fisiologia , Ossos do Tarso/fisiologia , Pé/fisiologia , Humanos , Sapatos
5.
Opt Express ; 20(3): 1953-62, 2012 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-22330436

RESUMO

Motion analysis of optically trapped objects is demonstrated using a simple 2D Fourier transform technique. The displacements of trapped objects are determined directly from the phase shift between the Fourier transform of subsequent images. Using end- and side-view imaging, the stiffness of the trap is determined in three dimensions. The Fourier transform method is simple to implement and applicable in cases where the trapped object changes shape or where the lighting conditions change. This is illustrated by tracking a fluorescent particle and a myoblast cell, with subsequent determination of diffusion coefficients and the trapping forces.


Assuntos
Modelos Biológicos , Modelos Químicos , Mioblastos/fisiologia , Mioblastos/efeitos da radiação , Nanopartículas/química , Nanopartículas/efeitos da radiação , Pinças Ópticas , Animais , Movimento Celular/fisiologia , Movimento Celular/efeitos da radiação , Células Cultivadas , Simulação por Computador , Análise de Fourier , Camundongos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...