Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Glob Health ; 85(1)2019 06 18.
Artigo em Inglês | MEDLINE | ID: mdl-31225964

RESUMO

INTRODUCTION: With the extensively spread of industrialization in the world, noise exposure is becoming more prevalent in the industrial settings. The most important and definite harmful effects of sound include hearing loss, both permanent and temporary. OBJECTIVE: This study was designed aimed to use the C5 algorithm to determine the weight of factors affecting the workers' hearing loss based on the audiometric data. METHODS: This cross-sectional, descriptive, analytical study was conducted in 2018 in a mining industry in southeastern Iran. In this study, workers were divided into three exposed groups with different sound pressure levels (one control group and two case groups). Audiometry was conducted for each group of 50 persons; hence, the total number of subjects was 150. The stages of this study include: 1) selecting factors (predictive) to check and weigh them; 2) conducting the audiometry for both ears; 3) calculating the permanent hearing loss in each ear and permanent hearing loss of both ears; 4) classifying the types of hearing loss; and 5) investigating and determining the weight of factors affecting the hearing loss and their classification based on the C5 algorithm and determining the error and accuracy rate of each model. To assess and determine the factors affecting the hearing loss of workers, the C5 algorithm and IBM SPSS Modeler 18.0 were used. SPSS V.18 was used to analyze the linear regression and paired t-test tests, too. RESULTS: The results showed that in the first model (SPL <70 dBA), the 8KHz frequency with the weight of 31% had the highest effect, the factors of work experience and the frequency of 250Hz each with the weight of 3%, had the least effect, and the accuracy of the model was 100%. In the second model (SPL 70-80 dBA) the frequency of 8KHz with the weight of 21% had the highest effect, the frequency of 250Hz and the working experience each had the lowest effect with the weight of 7% and the accuracy of the model was calculated as 100%. In the third model (SPL >85 dBA), the 4KHz frequency with the weight of 31% had the highest effect, and the work experience with a weight of 1% had the lowest effect, and the accuracy of the model was 94%. In the fourth model, the 4KHz frequency with the weight of 22% had the highest effect and 250Hz and age each with the weight of 8% had the lowest effects; the accuracy of this model was calculated to be 99.05%. CONCLUSIONS: During investigating and determining the weight of the factors affecting hearing loss by the C5 algorithm, the high weight and effect of the 4KHz frequency were predicted in hearing loss changes. Considering the high accuracy obtained in this modeling, this algorithm is a suitable and powerful tool for predicting and modeling the hearing loss.


Assuntos
Algoritmos , Audiometria/métodos , Perda Auditiva Provocada por Ruído/epidemiologia , Ruído Ocupacional/efeitos adversos , Doenças Profissionais/epidemiologia , Exposição Ocupacional/efeitos adversos , Estudos Transversais , Humanos , Irã (Geográfico)/epidemiologia , Mineração , Valor Preditivo dos Testes , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...