Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sci Total Environ ; 744: 140908, 2020 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-32721678

RESUMO

It is important that efficient measures to reduce the airborne transmission of respiratory infectious diseases (including COVID-19) should be formulated as soon as possible to ensure a safe easing of lockdown. Ventilation has been widely recognized as an efficient engineering control measure for airborne transmission. Room ventilation with an increased supply of clean outdoor air could dilute the expiratory airborne aerosols to a lower concentration level. However, sufficient increase is beyond the capacity of most of the existing mechanical ventilation systems that were designed to be energy efficient under non-pandemic conditions. We propose an improved control strategy based on source control, which would be achieved by implementing intermittent breaks in room occupancy, specifically that all occupants should leave the room periodically and the room occupancy time should be reduced as much as possible. Under the assumption of good mixing of clean outdoor supply air with room air, the evolution of the concentration in the room of aerosols exhaled by infected person(s) is predicted. The risk of airborne cross-infection is then evaluated by calculating the time-averaged intake fraction. The effectiveness of the strategy is demonstrated for a case study of a typical classroom. This strategy, together with other control measures such as continuous supply of maximum clean air, distancing, face-to-back layout of workstations and reducing activities that increase aerosol generation (e.g., loudly talking and singing), is applicable in classrooms, offices, meeting rooms, conference rooms, etc.


Assuntos
Poluição do Ar em Ambientes Fechados , Infecções por Coronavirus , Pandemias , Pneumonia Viral , Betacoronavirus , COVID-19 , Humanos , SARS-CoV-2 , Ventilação
2.
Indoor Air ; 28(4): 500-524, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29683213

RESUMO

This article reviews past studies of airborne transmission between occupants in indoor environments, focusing on the spread of expiratory droplet nuclei from mouth/nose to mouth/nose for non-specific diseases. Special attention is paid to summarizing what is known about the influential factors, the inappropriate simplifications of the thermofluid boundary conditions of thermal manikins, the challenges facing the available experimental techniques, and the limitations of available evaluation methods. Secondary issues are highlighted, and some new ways to improve our understanding of airborne transmission indoors are provided. The characteristics of airborne spread of expiratory droplet nuclei between occupants, which are influenced correlatively by both environmental and personal factors, were widely revealed under steady-state conditions. Owing to the different boundary conditions used, some inconsistent findings on specific influential factors have been published. The available instrumentation was too slow to provide accurate concentration profiles for time-dependent evaluations of events with obvious time characteristics, while computational fluid dynamics (CFD) studies were mainly performed in the framework of inherently steady Reynolds-averaged Navier-Stokes modeling. Future research needs in 3 areas are identified: the importance of the direction of indoor airflow patterns, the dynamics of airborne transmission, and the application of CFD simulations.


Assuntos
Movimentos do Ar , Poluição do Ar em Ambientes Fechados/análise , Hidrodinâmica , Microbiologia do Ar , Simulação por Computador , Expiração , Humanos , Manequins
3.
Indoor Air ; 26(2): 259-73, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25787963

RESUMO

Previous studies regarding interunit dispersion used Reynolds-averaged Navier-Stokes (RANS) models and thus obtained only mean dispersion routes and re-entry ratios. Given that the envelope flow around a building is highly fluctuating, mean values could be insufficient to describe interunit dispersion. This study investigates the wind-induced interunit dispersion around multistory buildings using the large eddy simulation (LES) method. This is the first time interunit dispersion has been investigated transiently using a LES model. The quality of the selected LES model is seriously assured through both experimental validation and sensitivity analyses. Two aspects are paid special attention: (i) comparison of dispersion routes with those provided by previous RANS simulations and (ii) comparison of timescales with those of natural ventilation and the survival times of pathogens. The LES results reveal larger dispersion scopes than the RANS results. Such larger scopes could be caused by the fluctuating and stochastic nature of envelope flows, which, however, is canceled out by the inherent Reynolds-averaged treatment of RANS models. The timescales of interunit dispersion are comparable with those of natural ventilation. They are much shorter than the survival time of most pathogens under ordinary physical environments, indicating that interunit dispersion is a valid route for disease transmission.


Assuntos
Simulação por Computador , Vento , Modelos Teóricos
4.
Build Environ ; 94: 489-503, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32288035

RESUMO

Many buildings in urban areas are more or less naturally ventilated. A good understanding of the current status and issues of indoor environmental quality (IEQ) in naturally ventilated urban buildings and the association with urban microclimate is fundamental for improving their IEQ. This paper reviews past studies on (a) the microclimate in urban street canyons, (b) the potential influence of such microclimate on IEQ of nearby naturally ventilated buildings, and (c) the real-life IEQ status in these buildings. The review focuses mainly on studies conducted by on-site measurements. The microclimate in urban street canyons is characterized by low wind speed, high surface temperature difference, high pollutant concentration, and high noise level. Insufficient ventilation rates and excessive penetration of outdoor pollutants are two key risks involved in naturally ventilated urban buildings. Existing knowledge suggests that reasonable urban planning and careful building envelope design are the primary methods to ensure acceptable IEQ and maximize the utilization of natural ventilation. However, quantitative studies of both microclimate in street canyons and IEQ in buildings are still highly insufficient in many aspects, which make cross comparison and influencing factors analysis currently impossible. Based on the limitations of previous studies and the current issues of naturally ventilated urban buildings, suggestions are made for future studies to better understand and improve IEQ in naturally ventilated urban buildings.

5.
Indoor Air ; 23(5): 417-29, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23495766

RESUMO

Compared with the buoyancy-dominated upward spread, the interunit dispersion of pollutants in wind-dominated conditions is expected to be more complex and multiple. The aim of this study is to investigate the wind-induced airflow and interunit pollutant dispersion in typical multistory residential buildings using computational fluid dynamics. The mathematical model used is the nonstandard k-ε model incorporated with a two-layer near-wall modification, which is validated against experiments of previous investigators. Using tracer gas technique, the reentry of exhaust air from each distinct unit to other units on the same building, under different practical conditions, is quantified, and then, the possible dispersion routes are revealed. The units on the floor immediately below the source on the windward side, and vertically above it on the leeward side, where the reentry ratios are up to 4.8% and 14.9%, respectively, should be included on the high-infection list. It is also found that the presence of balconies results in a more turbulent near-wall flow field, which in turn significantly changes the reentry characteristics. Comparison of the dispersion characteristics of the slab-like building and the more complicated building in cross (#) floorplan concludes that distinctive infectious control measures should be implemented in these two types of buildings.


Assuntos
Modelos Teóricos , Ventilação , Vento , Habitação , Controle de Infecções
6.
ScientificWorldJournal ; 2013: 195763, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24385871

RESUMO

The accurate prediction of pressure losses across in-duct fittings is of significance in relation to the accurate sizing and good energy efficiency of air-delivery systems. Current design guides provide design methods and data for the prediction of pressure losses only for a single and isolated fitting. This study presents an investigation of pressure losses across multiple interactive in-duct fittings in a ventilation duct. A laboratory measurement of pressure losses across one fitting and multiple fittings in a ventilation duct is carried out. The pressure loss across multiple interactive fittings is lower than that across multiple similar individual fittings, while the percentage decrease is dependent on the configuration and combination of the fittings. This implies that the pressure loss across multiple closely mounted fittings calculated by summing the pressure losses across individual fittings, as provided in the ASHRAE handbook and the CIBSE guide, is overpredicted. The numerical prediction of the pressure losses across multiple fittings using the large-eddy simulation (LES) model shows good agreement with the measured data, suggesting that this model is a useful tool in ductwork design and can help to save experimental resources and improve experimental accuracy and reliability.


Assuntos
Modelos Teóricos , Ventilação , Ar Condicionado/instrumentação , Desenho de Equipamento , Pressão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...