Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Cardiovasc Electrophysiol ; 28(9): 984-993, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28635046

RESUMO

BACKGROUND AND OBJECTIVE: Contact force (CF) sensing is a novel technology used for catheter ablation of atrial fibrillation (AF). We compared the single procedure success of CF-guided pulmonary vein isolation (PVI) with that of non-CF guided PVI during a 3-year (1,095 days) follow up period and analyzed the pattern of pulmonary vein (PV) reconnection. METHODS: A cohort of 167 subjects (68 CF vs. 99 non-CF) with paroxysmal AF were included in the study. Atrial arrhythmia (AA) recurrence was defined as documented AF, atrial flutter, or atrial tachycardia lasting >30 seconds and occurring after 90 days. RESULTS: Subjects in the CF group showed a statistically nonsignificant improvement in AA free survival compared to those in the non-CF group (66.2% vs. 51.5%; P value: 0.06). A greater propensity for reconnection was noted around the right-sided PVs compared to left-sided PVs related in both catheter ablation groups. For example, in the CF group 36% of right-sided segments reconnected compared to 16% of left-sided segments (P value <0.01). CONCLUSIONS: A greater propensity for reconnection was noted around the right sided PV segments in both the CF and non-CF groups. The explanation for this finding was related to greater catheter instability around the right sided veins. Further research is needed to explore the utility of a "real-time" composite indicator that includes RF energy, CF and catheter stability in predicting transmural lesion formation during catheter ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Taquicardia Paroxística/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Mapeamento Potencial de Superfície Corporal/métodos , Desenho de Equipamento , Feminino , Seguimentos , Sistema de Condução Cardíaco/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Estudos Retrospectivos , Taquicardia Paroxística/diagnóstico , Taquicardia Paroxística/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
2.
J Cardiovasc Magn Reson ; 16: 52, 2014 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-25160654

RESUMO

BACKGROUND: Serial surveillance endomyocardial biopsies are performed in patients who have recently undergone heart transplantation in order to detect acute cardiac allograft rejection (ACAR) before symptoms occur, however the biopsy process is associated with a number of limitations. This study aimed to prospectively and longitudinally evaluate the performance of multiparametric cardiovascular magnetic resonance (CMR) for detecting and monitoring ACAR in the early phase post-transplant, and characterize graft recovery following transplantation. METHODS: All patients receiving a heart transplant at a single UK centre over a period of 25 months were approached within one month of transplantation. Multiparametric CMR was prospectively performed on the same day as biopsy on four separate occasions (6 weeks, 10 weeks, 15 weeks and 20 weeks post-transplant). CMR included assessment of global and regional ventricular function, myocardial tissue characterization (T1 mapping, T2 mapping, extracellular volume, LGE) and pixel-wise absolute myocardial blood flow quantification. CMR parameters were compared with biopsy findings. As is standard, grade 2R or higher ACAR was considered significant. RESULTS: 88 CMR-matched biopsies were performed in 22 patients. Eight (9%) biopsies in 5 patients demonstrated significant ACAR. Significant ACAR was associated with a reduction in circumferential strain (-12.7±2.5% vs. -13.7±3.6%, p=0.047) but there was considerable overlap between groups. Whilst trends were observed between ACAR and proposed CMR markers of oedema, particularly after adjusting for primary graft dysfunction, differences were not significant. Significant improvements were seen in markers of graft structure and contractility, oedema and microvascular function over the period studied, although few parameters normalised. CONCLUSIONS: This study provides novel insight into the myocardial injury associated with transplantation, and its recovery, however multiparametric CMR was not able to accurately detect ACAR during the early phase post-transplantation.


Assuntos
Rejeição de Enxerto/diagnóstico , Transplante de Coração/efeitos adversos , Imageamento por Ressonância Magnética , Miocárdio/patologia , Doença Aguda , Adulto , Aloenxertos , Biópsia , Circulação Coronária , Diagnóstico Precoce , Inglaterra , Feminino , Rejeição de Enxerto/etiologia , Rejeição de Enxerto/patologia , Rejeição de Enxerto/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Contração Miocárdica , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Recuperação de Função Fisiológica , Fatores de Tempo , Resultado do Tratamento , Função Ventricular Esquerda
3.
J Cardiovasc Magn Reson ; 16: 11, 2014 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-24460930

RESUMO

BACKGROUND: Quantitative assessment of myocardial blood flow (MBF) from cardiovascular magnetic resonance (CMR) perfusion images appears to offer advantages over qualitative assessment. Currently however, clinical translation is lacking, at least in part due to considerable disparity in quantification methodology. The aim of this study was to evaluate the effect of common methodological differences in CMR voxel-wise measurement of MBF, using position emission tomography (PET) as external validation. METHODS: Eighteen subjects, including 9 with significant coronary artery disease (CAD) and 9 healthy volunteers prospectively underwent perfusion CMR. Comparison was made between MBF quantified using: 1. Calculated contrast agent concentration curves (to correct for signal saturation) versus raw signal intensity curves; 2. Mid-ventricular versus basal-ventricular short-axis arterial input function (AIF) extraction; 3. Three different deconvolution approaches; Fermi function parameterization, truncated singular value decomposition (TSVD) and first-order Tikhonov regularization with b-splines. CAD patients also prospectively underwent rubidium-82 PET (median interval 7 days). RESULTS: MBF was significantly higher when calculated using signal intensity compared to contrast agent concentration curves, and when the AIF was extracted from mid- compared to basal-ventricular images. MBF did not differ significantly between Fermi and Tikhonov, or between Fermi and TVSD deconvolution methods although there was a small difference between TSVD and Tikhonov (0.06 mL/min/g). Agreement between all deconvolution methods was high. MBF derived using each CMR deconvolution method showed a significant linear relationship (p<0.001) with PET-derived MBF however each method underestimated MBF compared to PET (by 0.19 to 0.35 mL/min/g). CONCLUSIONS: Variations in more complex methodological factors such as deconvolution method have no greater effect on estimated MBF than simple factors such as AIF location and observer variability. Standardization of the quantification process will aid comparison between studies and may help CMR MBF quantification enter clinical use.


Assuntos
Doença da Artéria Coronariana/diagnóstico , Circulação Coronária , Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Tomografia por Emissão de Pósitrons , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes
4.
J Invasive Cardiol ; 23(3): E58-60, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21364253

RESUMO

This case illustrates a complication following deployment of the Angioseal® vascular closure device after routine angiography. The AngioSeal device is a percutaneous, bioabsorbable, collagen-based hemostatic plug deployed to seal the arterial puncture. We describe a 69-year-old gentleman who presented with unilateral leg cramps 1 week post-procedure. When seen in the cardiology clinic, a magnetic resonance imaging angiogram was requested, which showed a filling defect in the right popliteal artery. The collagen seal had embolized and was subsequently removed by the vascular surgeons.


Assuntos
Angiografia Coronária/efeitos adversos , Técnicas Hemostáticas/efeitos adversos , Perna (Membro) , Dor/etiologia , Idoso , Angioplastia Coronária com Balão , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Técnicas Hemostáticas/instrumentação , Humanos , Perna (Membro)/irrigação sanguínea , Angiografia por Ressonância Magnética , Masculino , Dor/diagnóstico por imagem , Artéria Poplítea/patologia , Artéria Poplítea/cirurgia , Resultado do Tratamento , Procedimentos Cirúrgicos Vasculares
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...