Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Hypertens Res ; 46(6): 1450-1455, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36977899

RESUMO

The association of blood pressure and temperature is well known in seasonal observation, and low temperature in the winter season is often considered a cause of high blood pressure. The current evidence for short-term studies of temperature and blood pressure is based on the daily observation, however continuous monitoring with wearable devices will allow us to evaluate the rapid effect of cold temperature exposure on blood pressure. In a Japanese, prospective intervention study from 2014 to 2019 (the Smart Wellness Housing survey), approximately 90% of Japanese lived in cold houses (indoor temperature less than 18 °C). Importantly, the indoor temperature was associated with the increase of morning systolic blood pressure. We recently addressed the sympathetic nervous activation of individuals in both their houses and a highly insulated and airtight model house in the winter season using portable electrocardiography equipment. A few subjects showed a morning surge in sympathetic activity, which was more intense at their cold houses, which suggests the importance of the indoor environment in the management of early morning hypertension. In near future, real-time monitoring with wearable devices will provide important information for a better life-environment, leading to risk reduction of morning surge and cardiovascular events.


Assuntos
Hipertensão , Dispositivos Eletrônicos Vestíveis , Humanos , Pressão Sanguínea/fisiologia , Temperatura , Estudos Prospectivos , Monitorização Ambulatorial da Pressão Arterial
2.
Hypertens Res ; 46(1): 231-235, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36224284

RESUMO

We addressed to the sympathetic nervous activation of the same people in both their houses and a highly insulated and airtight model house (model house) during the cold winter season. Eight subjects (4 males and 4 females) stayed two nights at each house and were continuously monitored for sympathetic nerve system by calculating LF (low frequency)/HF (high frequency) in the analysis of heart rate variability using a wearable electrocardiography equipment. The room temperatures were kept constant at 20 °C or more in model house, but much lower in their houses. In all subjects, the sleeping duration is longer in model house compared with that in the participants' houses. Four subjects showed a morning surge in sympathetic activity that were more intense at their houses. This morning surge in sympathetic activity in a residential setting suggests the importance of the indoor environment in the management of early morning hypertension.


Assuntos
Ritmo Circadiano , Hipertensão , Masculino , Feminino , Humanos , Estações do Ano , Ritmo Circadiano/fisiologia , Sistema Nervoso Simpático , Frequência Cardíaca/fisiologia
3.
BMC Oral Health ; 20(1): 228, 2020 08 20.
Artigo em Inglês | MEDLINE | ID: mdl-32819330

RESUMO

BACKGROUND: The design process of a removable partial denture (RPD) consists of rests, major connectors, minor connectors, denture base, and retainer. The abutment tooth contour determines the location of the retention portion of the clasp at the retention areas. The load capacity of the clasp depends on various factors such as type, the position of a clasp, tooth position, clasp length, and pullout location. As a general rule, the amount of retention required to dislodge the RPD from the supporting structure should always be the minimum necessary to resist reasonable dislodging forces. Excessive force from the clasps may cause many problems. Although there are many reports on the retentive force of cast clasps using large devices, it has not been possible to measure it using simple devices until now. METHOD: The purpose of the present study is to develop a small-sized retentive force measurement device that can easily measure the retentive force of a clasp used for an RPD. It is to examine inter-rater and intra-rater reliability. A small-sized retentive force measurement device that can be easily measured in the laboratory has been developed. Using commercially available hard plaster cast, a skilled dental technician has made 10 types of cast clasps used in clinical practice using conventional techniques. Three assessors measured the retentive force of 10 types of cast clasps. To confirm the reliability, the intra-class correlation coefficients ICC (1,1) and ICC (1,3) of the 3 assessors were calculated, and the reliability within the assessor was examined. The inter-class correlation coefficients ICC (3,1) and ICC (3,3) were calculated, and the reliability of the assessors was examined. RESULT: The intra-class correlation coefficients of 3 assessors are as follows: assessor 1 has ICC (1,1) = 0.971, ICC (1,3) = 0.990, assessor 2 has ICC (1,1) = 0.967, ICC (1,3) = 0.989, assessor 3 has ICC (1,1) = 0.962, ICC (1,3) = 0.987. The inter-class correlation coefficients of 3 assessors are as follows: ICC (3,1) = 0.993, ICC (3,3) = 0.998. From the evaluation standard of the intraclass correlation coefficients of reliability value by ICC, it was evaluated as almost perfect and high reproducibility was confirmed. CONCLUSION: The developed small-sized retentive force measurement device has reproducibility within and between the assessors.


Assuntos
Grampos Dentários , Prótese Parcial Removível , Retenção de Dentadura , Reprodutibilidade dos Testes
4.
ACG Case Rep J ; 3(3): 172-4, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27144195

RESUMO

A 47-year-old woman underwent prophylactic subtotal colectomy with ileorectal anastomosis (IRA) for familial adenomatous polyposis (FAP) 18 years ago. She underwent 5 transanal endoscopic microsurgeries for rectal remnant polyps, and was referred for the treatment of rectal remnant polyp recurrence. Endoscopic submucosal dissection (ESD) was performed to remove multiple polypoid lesions that circumferentially extended throughout the rectal remnant with lesions spreading onto the anastomotic site. The rectal remnant mucosa was resected in 2 pieces without complication. Specimens showed high-grade adenoma but no malignancy. Follow-up colonoscopy showed no recurrence.

5.
ACG Case Rep J ; 2(3): 146-9, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26157945

RESUMO

Sixteen non-ampullary duodenal neoplasms in 16 patients were treated with endoscopic submucosal dissection (ESD) performed by an endoscopist and an instrument assistant between February 2011 and November 2014. En bloc resection was performed in 15 cases (94%); lateral and vertical margins were pathologically free in 13 cases. Perforation occurred during submucosal dissection using a flex knife, but no perforations occurred in 15 cases using the hook knife only. No postoperative bleeding nor recurrence has been reported in any patient during the median 17-month follow-up period. Use of the hook knife as the main instrument and targeted training of the endoscopist and instrument assistant contributed to safe and effective duodenal ESD for non-ampullary duodenal neoplasms.

6.
Bull Tokyo Dent Coll ; 54(3): 127-33, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24334625

RESUMO

A facilities-group system designed to provide clinical training at dental clinics was developed after postgraduate clinical training became mandatory for dentists in Japan in 2006. As a result, there has been a steady increase in the number of dental clinics collaborating with dental school hospitals under this program. A larger number of dental clinics have also been designated as single-system facilities, program management facilities or collaborating facilities. However, it remains to be determined whether this increase in the number of dental clinics designated as clinical training facilities has led to an increase in the amount of training offered. Therefore, the purpose of this study was to investigate trends in the percentage of postgraduate dental trainees at dental clinics between fiscal years 2006 and 2010. The results showed no significant correlation among (1) the percentage of dental clinics designated as single-system collaborating facilities, (2) the percentage of training programs at dental clinics, and (3) the proportion of training program recruitment offers by dental clinics compared to the total number of recruits. These findings showed that increasing the number of collaborating dental clinics did not lead to an increase in the amount of clinical training at dental clinics. The findings also suggest that increasing the number of single-system or program management dental clinics is important in promoting clinical training at dental clinics.


Assuntos
Clínicas Odontológicas/estatística & dados numéricos , Educação em Odontologia/estatística & dados numéricos , Internato e Residência/estatística & dados numéricos , Currículo , Hospitais de Ensino/estatística & dados numéricos , Humanos , Japão , Seleção de Pessoal/estatística & dados numéricos , Faculdades de Odontologia/estatística & dados numéricos
7.
Endocr J ; 58(2): 131-5, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21186332

RESUMO

We have made step-up titration protocol with biphasic insulin aspart-70/30 (BIAsp 30), and tried to achieve glycemic goals in poorly controlled Japanese type 2 diabetic patients. We summarized all results obtained to analyze the effectiveness of our protocol. The target of glycaemic control was defined as HbA1c over 7.0 %. In our insulin initiation protocol, all patients started a once-daily injection of BIAsp 30 before the breakfast in addition to their oral hypoglycaemic agents. The patients who could not achieve the target from 12 to 16 weeks after the start of insulin treatment proceeded to twice daily insulin injection before breakfast and dinner. Next, the patients who could not achieve the target from 12 to 16 weeks after the addition of another BIAsp injection proceeded to thrice daily insulin injection before each meal a day. The results of 39 patients were analyzed, and 10.3 % of all patients achieved the target after the start of once daily injection of BIAsp 30, 41.7 % achieved in twice daily injection of BIAsp, and 51.4 % achieved in thrice daily injection of BIAsp. Daily insulin dose at the end of each treatment was 9.3±4.1 U in once daily, 17.4±6.3 U in twice daily, and 28.4±10.4 U in thrice daily. Total body weight increase by 2.0±2.6 kg. The initiation and titration protocol with BIAsp 30 improved glycaemic control, and increased the number of patients with the achievement of glycaemic goals.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 2/tratamento farmacológico , Insulina/análogos & derivados , Idoso , Insulinas Bifásicas , Diabetes Mellitus Tipo 2/sangue , Quimioterapia Combinada , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemiantes/administração & dosagem , Insulina/administração & dosagem , Insulina Aspart , Insulina Isófana , Japão , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
8.
Bull Tokyo Dent Coll ; 50(2): 63-70, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19815993

RESUMO

Postgraduate clinical training for dentists in Japan became mandatory in April 2006. Mandatory postgraduate clinical training for physicians has been criticized as having accelerated the imbalance in distribution of physicians. This suggests the danger that the same phenomenon might occur in distribution of dentists. It is also necessary to investigate the geographic distribution of dental trainees and practicing dentists in Japan. In this study, the number of dental trainees enrolled in each clinical training program and number that had actually received clinical training at each facility were compared by prefecture. The results suggest that disparities in the number of dental trainees among prefectures are being compensated for by movement across prefectural borders under the clinical training facilities-group system. Postgraduate dental trainees, however, showed a significantly greater imbalance in geographic distribution than practicing dentists. Continuation of the postgraduate clinical training for dentists under the existing system may accelerate this imbalance in distribution of dentists. To prevent this, practical measures should be taken in accordance with the coming review of the system, based on research regarding changes in geographic distribution of dental trainees.


Assuntos
Instalações Odontológicas/provisão & distribuição , Odontólogos/provisão & distribuição , Educação de Pós-Graduação em Odontologia/estatística & dados numéricos , Área de Atuação Profissional/estatística & dados numéricos , Estudantes de Odontologia/estatística & dados numéricos , Clínicas Odontológicas/provisão & distribuição , Humanos , Japão
9.
Artigo em Inglês | MEDLINE | ID: mdl-15897016

RESUMO

High performance liquid chromatographic (HPLC) methods were validated for the determination of aripiprazole (OPC-14597, Abilify) in rat plasma and brain. Separation was by Nova-pak phenyl column; flow rate, 1.0 ml/min; mobile phase, acetonitrile-methanol-20 mM sodium sulfate-acetic acid (27:25:48:1, v/v/v/v); UV detection at 254 nm. Reproducibility in plasma and brain showed excellent precision (within 7.8 and 10.6%) and accuracy (96.0-102.4% and 99.0-108.7%) with calibration curve ranges 10.0-2000 ng/ml and 30.0-6000 ng/g, respectively. Validated HPLC methods were successfully applied to pharmacokinetic study of aripiprazole in rats, demonstrating brain concentrations after oral administration five times higher than plasma concentrations.


Assuntos
Antipsicóticos/análise , Cromatografia Líquida de Alta Pressão/métodos , Piperazinas/análise , Quinolonas/análise , Animais , Antipsicóticos/sangue , Antipsicóticos/farmacocinética , Aripiprazol , Química Encefálica , Estabilidade de Medicamentos , Congelamento , Masculino , Piperazinas/sangue , Piperazinas/farmacocinética , Quinolonas/sangue , Quinolonas/farmacocinética , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta
10.
Bioconjug Chem ; 16(1): 208-14, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15656593

RESUMO

We designed poly(amidoamine) dendrimers with phenylalanine or leucine residues at their chain ends. Thereby, we achieved efficient gene transfection of cells through synergy of the proton sponge effect, which is induced by the internal tertiary amines of the dendrimer, and hydrophobic interaction by the hydrophobic amino acid residues in the dendrimer periphery. Dendrimers having 16, 29, 46, and 64 terminal phenylalanine residues were prepared by the reaction of the amine-terminated poly(amidoamine) G4 dendrimer and L-phenylalanine using condensing reagent 1,3-dicyclohexylcarbodiimide. Transfection activity of these phenylalanine-modified dendrimers for CV1 cells, an African green monkey kidney cell line, increased concomitant with the increasing number of the terminal phenylalanine residues, except for the dendrimer with 64 phenylalanine residues, which showed poor water solubility and hardly formed a complex with DNA at neutral pH. However, under weakly acidic conditions, the dendrimer with 64 phenylalanine residues formed a complex with DNA, thereby achieving highly efficient transfection. In contrast, the attachment of L-leucine residues was unable to improve the transfection activity of the parent dendrimer, probably because of the relatively lower hydrophobicity of this amino acid. The phenylalanine-modified dendrimer exhibited a higher transfection activity and a lower cytotoxicity than some widely used transfection reagents. For that reason, the phenylalanine-modified dendrimers are considered to be promising gene carriers.


Assuntos
Aminoácidos/química , Técnicas de Transferência de Genes , Poliaminas/química , Transfecção/métodos , Animais , Linhagem Celular , Células Cultivadas , DNA/química , Haplorrinos , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Rim/metabolismo , Luciferases/metabolismo , Fenilalanina/química , Poliaminas/farmacologia , Testes de Toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...