1.
Magn Reson Med Sci ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38346767

RESUMO

PURPOSE: The purpose of this study was to do a feasibility study on a microstrip transmission line (MS) RF coil for a positron emission tomography (PET) insert in a 7 Tesla human MRI system. The proposed MS coil integrated the RF shield of the PET detector as the ground conductor of the coil. We called the integrated module "MS PET coil." METHODS: A single-channel MS PET coil was developed with an integrated RF-shielded PET detector module. For comparison, we also studied a conventional MS coil with a single-layer ground conductor. A lutetium fine silicate (LFS) scintillation crystal block (14 × 14 × 4-layer) with a silicon photomultiplier (Hamamatsu Photonics K.K., Shizuoka, Japan) and a front-end readout circuit board were mounted inside the shield cage of the MS PET coil. The MS PET coil was studied with and without PET detectors. All three coil configurations were studied with a homogeneous phantom in a 7T MRI system (Siemens Healthineers, Erlangen, Germany). PET data measurements were conducted using a Cesium-137 radiation point source. RESULTS: The MR images were similar for the MS coil and the empty MS PET coil, as well as for the cases of MS PET coil with and without PET measurements. Compared to the empty MS PET coil (without PET detector and cable RF shield), decreases in SNR, increases in image noise and RF power, and a slight decrease in resonance frequency were seen for the case of the MS PET coil with the detector and cable shield. Differences in the PET energy histograms or in the crystal identification maps with and without MRI measurements were negligible. CONCLUSIONS: Both the MRI and PET performances of the MS PET coil showed responses that matched the MS coil responses. The performance variations of MRI data with and without PET measurement and PET data with and without MR imaging were negligible.

2.
Radiol Phys Technol ; 17(1): 60-70, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37874462

RESUMO

The purpose of this study is to evaluate the RF field responses of partial-ring RF-shielded oval-shaped positron emission tomography (PET) inserts that are used in combination with an MRI body RF coil. Partial-ring PET insert is particularly suitable for interventional investigation (e.g., trimodal PET/MRI/ultrasound imaging) and intraoperative (e.g., robotic surgery) PET/MRI studies. In this study, we used electrically floating Faraday RF shield cages to construct different partial-ring configurations of oval and cylindrical PET inserts and performed experiments on the RF field, spin echo and gradient echo images for a homogeneous phantom in a 3 T clinical MRI system. For each geometry, partial-ring configurations were studied by removing an opposing pair or a single shield cage from different positions of the PET ring. Compared to the MRI-only case, reduction in mean RF homogeneity, flip angle, and SNR for the detector opening in the first and third quadrants was approximately 13%, 15%, and 43%, respectively, whereas the values were 8%, 23%, and 48%, respectively, for the detector openings in the second and fourth quadrants. The RF field distribution also varied for different partial-ring configurations. It can be concluded that the field penetration was high for the detector openings in the first and third quadrants of both the inserts.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Desenho de Equipamento , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio
3.
Jpn J Radiol ; 42(4): 382-390, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38110835

RESUMO

PURPOSE: To perform an MRI compatibility study of an RF field-penetrable oval-shaped PET insert that implements an MRI built-in body RF coil both as a transmitter and a receiver. METHODS: Twelve electrically floating RF shielded PET detector modules were used to construct the prototype oval PET insert with a major axis of 440 mm, a minor axis of 350 mm, and an axial length of 225 mm. The electric floating of the PET detector modules was accomplished by isolating the cable shield from the detector shield using plastic tape. Studies were conducted on the transmit (B1) RF field, the image signal-to-noise ratio (SNR), and the RF pulse amplitude for a homogeneous cylindrical (diameter: 160 mm and length: 260 mm) phantom (NaCl + NiSO4 solution) in a 3 T clinical MRI system (Verio, Siemens, Erlangen, Germany). RESULTS: The B1 maps for the oval insert were similar to the MRI-only field responses. Compared to the MRI-only values, SNR reductions of 51%, 45%, and 59% were seen, respectively, for the spin echo (SE), gradient echo (GE), and echo planar (EPI) images for the case of oval PET insert. Moreover, the required RF pulse amplitudes for the SE, GE, and EPI sequences were, respectively, 1.93, 1.85, and 1.36 times larger. However, a 30% reduction in the average RF reception sensitivity was observed for the oval insert. CONCLUSIONS: The prototype floating PET insert was a safety concern for the clinical MRI system, and this compatibility study provided clearance for developing a large body size floating PET insert for the existing MRI system. Because of the RF shield of the insert, relatively large RF powers compared to the MRI-only case were required. Because of this and also due to low RF sensitivity of the body coil, the SNRs reduced largely.


Assuntos
Imageamento por Ressonância Magnética , Tomografia por Emissão de Pósitrons , Humanos , Tomografia por Emissão de Pósitrons/métodos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Ondas de Rádio , Razão Sinal-Ruído
4.
Heliyon ; 9(7): e17961, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37483766

RESUMO

This present study involves the formation and investigation of the characteristics of a fabricated mat from a PVA-betel leaf mixture. Under ideal processing parameters, nanofibrous mat is synthesized from the PVA-betel leaf blended solution by using the electrospinning technique. Afterwards, the produced nanofibrous mat is assessed for its thermal, antibacterial, morphological, moisture management and chemical interaction behavior using thermogravimetric analysis (TGA), antibacterial assay, scanning electron microscope (SEM), moisture management tester (MMT) and Fourier-transform infrared spectroscopy (FTIR) respectively. The antibacterial action against Staphylococcus aureus and Escherichia coli bacteria has been assessed using the agar diffusion technique, which reveals the creation of zones of inhibition with a value of about 20 mm. Besides, the fabricated nanomat reveals an average diameter of 183.4 nm with improved moisture and thermal characteristics. Furthermore, the generated nanofibrous mat has all the necessary components, as evidenced by the distinctive peaks in the FTIR spectra. Hence, the recently developed nanofibrous mat exhibits promising potential as a suitable material for wound dressing applications.

5.
Insects ; 14(4)2023 Mar 31.
Artigo em Inglês | MEDLINE | ID: mdl-37103164

RESUMO

Fall armyworm (FAW), Spodoptera frugiperda, is a major pest of maize that was first detected in Bangladesh in 2018 and rapidly spread throughout the maize-growing areas. The presence of FAW was monitored using sex pheromone traps. Farmers' pest management practices were assessed through a questionnaire. The damage is most apparent in the early and late whorl stages. As the crop is grown mostly from November to April, both vegetative and reproductive growth stages remain vulnerable to extensive damage. The survey results showed that 100% of the farmers used pesticides for FAW control, 40.4% handpicked and crushed egg masses, 75.8% handpicked and crushed caterpillars, and only 5.4% used other techniques like applying ash/sand in the funnel of maize. Commonly used pesticides included Spinosad, Emamectin benzoate, Imidacloprid, and others. Thirty-four percent of farmers applied pesticides twice in a season and 48% applied pesticides three times in a season and 54% and 39% of farmers sprayed chemicals at 7-day and 15-day intervals, respectively. FAW causes an average economic loss of 37.7% in maize production without pesticides. Increased use of pesticides to control FAW poses hazards to human health, wildlife, and the environment, and is expensive. Therefore, well-tested agroecological practices and bio-control agents are needed for sustainable FAW management.

6.
J Popul Ther Clin Pharmacol ; 29(3): e1-e10, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36196933

RESUMO

India has a unique position with its vast population and rapidly increasing healthcare demand. Dental health is integral to a holistic health care need, and a robust dental education system is necessary. Dental education in India is mainly regulated by the Dental Councilof India, setting broad guidelines. Universities having dental colleges and institutes develop fine curriculum development and evaluation details. General and Dental Pharmacology and Therapeuticsis a crucial subject taught to undergraduate dental students during the second year of a 4-year duration course. A dental graduate should be well trained in general and systemic pharmacology and rational therapeutics principles. This has been set as an objective by the Dental Council of India. Sound knowledge of the drug action mechanisms, indications, adverse drug reactions, drug interactions and contraindications, evidence-based medicine, and rational use of adrug is core to the allopathic system. The practical exercises on human simulation or computer-assisted learning are critical for understanding pharmacology. The subject of pharmacology for dental graduates has been allotted 70 hours of theory and 20 hours of practicals with almost the same syllabus as medical graduates. This article highlights the areas of concern concerning the deficiency of teaching hours and needed improvement in the curriculum to make it competent to achieve its objective. The authors bring this much-needed topic for discussion among academicians and for the attention of regulatory authorities.


Assuntos
Currículo , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Educação em Odontologia , Humanos , Índia , Aprendizagem
7.
RSC Adv ; 12(12): 7210-7228, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35424670

RESUMO

This paper studies a new response surface methodology (RSM) based on the central composite design (CCD) modeling method to optimize the photocatalytic degradation of methylene blue (MB) and methyl orange (MO) by using a synthesized ZnO/Alg bionanocomposite under UV irradiation. ZnO with different content of sodium alginate (Alg) (10, 20, and 30% by weight) has been synthesized by a one-step sol-gel method. Zinc oxide (ZnO) nanoparticles were impregnated on the alginate polymer. Various characterization techniques were used to describe the physical and chemical properties of each catalyst such as XRD, FTIR, UV-vis, PL, FESEM, Raman, and BET. The optimal catalyst for MB and MO photocatalytic degradation process was discussed mathematically as a function of catalyst dose, irradiation time, and MB and MO concentration, which was modeled by CCD-RSM based on a statistical model (quadratic regression) and an optimization process (ANOVA analysis). The photocatalytic degradation efficiency of 98% was achieved for the optimal conditions of a dye concentration of 20 mg L-1, the catalyst dose of 0.34 g L-1, and an irradiation time of 90 min at pH 6. The measurement result (R 2 = 0.9901) showed that the considered model is very suitable, and the selected CCD-RSM successfully optimized the photodegradation conditions of MB and MO.

8.
Med Phys ; 49(5): 2965-2978, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35271749

RESUMO

PURPOSE: The positron emission tomography (PET) insert for a magnetic resonance imaging (MRI) system that implements the radiofrequency (RF) built-in body coil of the MRI system as a transmitter is designed to be RF-transparent, as the coil resides outside the RF-shielded PET ring. This approach reduces the design complexities (e.g., large PET ring diameter) related to implementing a transmit coil inside the PET ring. However, achieving the required field transmission into the imaging region of interest (ROI) becomes challenging because of the RF shield of the PET insert. In this study, a modularly RF-shielded PET insert is used to investigate the RF transparency considering two electrical configurations of the RF shield, namely the electrical floating and ground configurations. The purpose is to find the differences, advantages and disadvantages of these two configurations. METHODS: Eight copper-shielded PET detector modules (intermodular gap: 3 mm) were oriented cylindrically with an inner diameter of 234 mm. Each PET module included four-layer Lutetium-yttrium oxyorthosilicate scintillation crystal blocks and front-end readout electronics. RF-shielded twisted-pair cables were used to connect the front-end electronics with the power sources and PET data acquisition systems located outside the MRI room. In the ground configuration, both the detector and cable shields were connected to the RF ground of the MRI system. In the floating configuration, only the RF shields of the PET modules were isolated from the RF ground. Experiments were conducted using two cylindrical homogeneous phantoms in a 3 T clinical MRI system, in which the built-in body RF coil (a cylindrical volume coil of diameter 700 mm and length 540 mm) was implemented as a transceiver. RESULTS: For both PET configurations, the RF and MR imaging performances were lower than those for the MRI-only case, and the MRI system provided specific absorption ratio (SAR) values that were almost double. The RF homogeneity and field strength, and the signal-to-noise ratio (SNR) of the MR images were mostly higher for the floating PET configuration than they were for the ground PET configuration. However, for a shorter axial field-of-view (FOV) of 125 mm, both configurations offered almost the same performance with high RF homogeneities (e.g., 76 ± 10%). Moreover, for both PET configurations, 56 ± 6% larger RF pulse amplitudes were required for MR imaging purposes. The increased power is mostly absorbed in the conductive shields in the form of shielding RF eddy currents; as a result, the SAR values only in the phantoms were estimated to be close to the MRI-only values. CONCLUSIONS: The floating PET configuration showed higher RF transparency under all experimental setups. For a relatively short axial FOV of 125 mm, the ground configuration also performed well which indicated that an RF-penetrable PET insert with the conventional design (e.g., the ground configuration) might also become possible. However, some design modifications (e.g., a wider intermodular gap and using the RF receiver coil inside the PET insert) should improve the RF performance to the level of the MRI-only case.


Assuntos
Tomografia por Emissão de Pósitrons , Ondas de Rádio , Desenho de Equipamento , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons/métodos , Razão Sinal-Ruído
9.
J Mol Struct ; 1225: 129091, 2021 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-32834117

RESUMO

US Food and Drug Administration (FDA) allowed for direct addition of castor oil for human consumption as food and most recently FDA approved castor oil as over-the-counter (OTC) for laxative drug. The present article highlights the green route phosphorylation of castor oil (COL) via condensation polymerization. Further, the incorporation of metal ions Cu (II)) and Zn (II) into the polymer matrix have been carried out at elevated temperature using catalyst p-toluene sulphonic acid (PTSA). The modification of the said material has been confirmed by FT-IR, UV-VIS, and 1H and 31P-NMR spectroscopy. Further, the in vitro antibacterial activities of the metal incorporated-COL has been performed by standard methods against B. cereus (MCC2243) (gram-positive) and E. coli (MCC2412) (gram-negative) bacteria. The results revealed that the incorporation of metal ions into the polymer matrix increases the antibacterial activity largely. This may be governed by the electrostatic interaction between metal ions and microbes, also the generation of free active oxygen hinders the normal activity of bacteria. These results suggest that the synthesized material may act a potential candidate for low cost, environment friendly antibacterial agents and may find their application in clinical fields. Herein we are also proposing mechanism of antibacterial activity.

11.
Protein Pept Lett ; 27(10): 989-998, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32342801

RESUMO

BACKGROUND: Peroxynitrite, a nitrating and oxidizing agent, is formed by the interaction between nitric oxide and superoxide radicals. H2A histone is a basic nucleoprotein and is one of the major core histones responsible for packaging DNA. It has been shown that they are highly sensitive to oxidizing and nitrating agents. OBJECTIVE: Nitration of tyrosine residues in proteins by peroxynitrite is regarded as a marker of nitrosative damage. The dityrosine bond, an oxidative covalent cross-link between two tyrosines in protein, is increasingly identified as a marker of oxidative stress, aging and neurodegerative diseases. METHODS: Peroxinitrite-mediated nitration and dinitration in H2A histone was assessed by various biophysical techniques. RESULTS: The data presented in this study showed that the dityrosine content was found to be elevated in H2A histone modified with peroxynitrite. The formation of dityrosine showed a decrease in fluorescence intensity, generation of a new peak in FT-IR, increase in hydrodynamic size, and loss of secondary and tertiary structure of H2A resulting in a partially folded structure. CONCLUSION: We report that H2A may undergo conformational and structural changes under nitrosative and oxidative stress from the deleterious effects of peroxynitrite.


Assuntos
Histonas/química , Ácido Peroxinitroso/química , Dobramento de Proteína , Animais , Humanos , Domínios Proteicos , Estrutura Secundária de Proteína , Tirosina/análogos & derivados , Tirosina/química
12.
Magn Reson Med Sci ; 19(2): 147-153, 2020 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31776297

RESUMO

PURPOSE: We proposed and developed a new microstrip transmission line radiofrequency (RF) coil for a positron emission tomography (PET) insert for MRI, which has low electrical interactions with PET shield boxes. We performed imaging experiments using a single-channel and a four-channel proposed RF coils for proof-of-concept. METHODS: A conventional microstrip coil consists of a microstrip conductor, a ground conductor, and a dielectric between the two conductors. We proposed a microstrip coil for the PET insert that replaced the conventional single-layer ground conductor with the RF shield of the PET insert. A dielectric material, which could otherwise attenuate gamma photons radiated from the PET imaging tracer, was not used. As proof-of-concept, we compared conventional and the proposed single-channel coils. To study multichannel performance, we further developed a four-channel proposed RF coil. Since the MRI system had a single-channel transmission port, an interfacing four-way RF power division circuit was designed. The coils were implemented as both RF transmitters and receivers in a cylindrical frame of diameter 150 mm. Coil bench performances were tested with a network analyzer (Rohde & Schwarz, Germany), and a homogeneous phantom study was conducted for gradient echo imaging and RF field (B1) mapping in a 3T clinical MRI system (Verio, Siemens, Erlangen, Germany). RESULTS: For all coils, the power reflection coefficient was below -30 dB, and the transmission coefficients in the four-channel configuration were near or below -20 dB. The comparative single-channel coil study showed good similarity between the conventional and proposed coils. The gradient echo image of the four-channel coil showed expected flashing image intensity near the coils and no phase distortion was visible. Transmit B1 field map resembled the image performance. CONCLUSION: The proposed PET-microstrip coil performed similarly to the conventional microstrip transmission line coil and is promising for the development of a compact coil-PET system capable of simultaneous PET/MRI analysis with an existing MRI system.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Desenho de Equipamento , Imagens de Fantasmas , Ondas de Rádio
13.
Food Chem ; 284: 213-218, 2019 Jun 30.
Artigo em Inglês | MEDLINE | ID: mdl-30744848

RESUMO

US Food and Drug Administration (FDA) permitted for direct addition of castor oil into food for human consumption and recently FDA approved castor oil as over-the-counter (OTC) for laxative drug. Castor oil (COL) is a vegetable oil and naturally polyol which is inexpensive, environmental friendly and a very valuable renewable resource. Metals are believed to influence antioxidant property of ligands. Metals copper, zinc, cobalt and barium were incorporated with castor oil and subsequently structures were established by FT-IR, UV-Visible, and 1H NMR spectroscopic techniques. In vitro antioxidant activities of metal containing COL were determined by DPPH and superoxide scavenging methods and the results were compared with vitamin C. Enhanced antioxidant nature of metal containing castor oil was noticed and compared to virgin castor oil. This study reveals that synthesized metal containing-COL is a potential antioxidant material.


Assuntos
Antioxidantes/farmacologia , Óleo de Rícino/química , Óleo de Rícino/farmacologia , Metais/farmacologia , Antioxidantes/química , Ácido Ascórbico/farmacologia , Cátions Bivalentes , Sequestradores de Radicais Livres/farmacologia , Ligantes , Espectroscopia de Ressonância Magnética , Metais/química , Espectroscopia de Infravermelho com Transformada de Fourier , Superóxidos/metabolismo
14.
Med Phys ; 45(10): 4627-4641, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30118140

RESUMO

PURPOSE: An electrically floating radio frequency (RF) shielded PET insert with individual PET detectors shielded by separate Faraday cages enables the MRI built-in body RF coil to be used at least as an RF transmitter, in which the RF field penetrates the imaging region inside the PET ring through the narrow gaps between the shielded PET detector modules. Because the shielded PET ring blocks more than 90% of the imaging region for the transmit field from the body RF coil, it is very challenging to obtain the required RF field inside a full-ring floating PET insert. In this study, experiments were performed on the dependence of RF penetrability on different geometric aspects of the shielded PET modules and PET rings to optimize the design parameters to obtain the required RF field inside the PET ring. METHODS: We developed several prototype cylindrical full-ring PET inserts using completely enclosed empty RF shield boxes (considered as dummy PET modules). Considering the RF shield box, we conducted studies for different axial lengths (240 and 120 mm) and heights (30 and 45 mm) of the shield boxes. On the other hand, considering the PET ring geometry, we also performed studies on three different categories of PET rings: a long-ring insert (longer than the MRI phantom), a short-ring insert (shorter than the MRI phantom), and a two-ring insert that combined two short-rings. In each ring category, two different inter-shield box gaps (1 and 3 mm) were considered. In the case of the two-ring insert, three different ring-gaps (5, 10, and 20 mm) were studied. In total, 21 PET inserts were studied with an inner diameter (i.d.) of 210 mm. To study the effect of ring diameter, another long-ring insert was studied for the 270 mm i.d. Experiments were conducted for the transmit RF (B1 ) fields and signal-to-noise ratios of spin-echo and gradient-echo images using a homogeneous phantom in a 700 mm bore-diameter 3 T clinical MRI system. RF pulse amplitudes generated automatically by the MRI system were recorded for comparison. RESULTS: A PET insert with a 3 mm inter-box gap was found to perform the best, at a level which is acceptable for PET imaging. In the case of an insert of multiple short-rings instead of one long-ring insert, the 5 and 10 mm ring-gaps provided higher RF field penetration. Increasing the inter-box gap improved the RF field penetration, whereas a ring-gap that was too wide concentrated the field near the ring-gap region. Relatively reduced RF power was required for wider inter-box gap or ring-gap or larger shield box height. Moreover, the rectangular shield box outperformed the trapezoidal shield box. On the other hand, when we changed the inner or outer diameter of the PET ring by keeping the same transaxial width of the shield boxes, we did not see any noticeable variation. CONCLUSIONS: Our study results provide comprehensive guidance on the geometrical design aspects of RF-penetrable PET inserts for efficient RF penetration inside the PET ring. By choosing proper geometric design parameters, we could get the RF field that was similar to the MRI-only case.


Assuntos
Eletricidade , Imageamento por Ressonância Magnética/instrumentação , Tomografia por Emissão de Pósitrons/instrumentação , Ondas de Rádio , Proteção Radiológica/instrumentação
15.
J Magn Reson ; 283: 62-70, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28881235

RESUMO

We have been working on the development of a PET insert for existing magnetic resonance imaging (MRI) systems for simultaneous PET/MR imaging, which integrates radiofrequency (RF)-shielded PET detector modules with an RF head coil. In order to avoid interferences between the PET detector circuits and the different MRI-generated electromagnetic fields, PET detector circuits were installed inside eight Cu-shielded fiber-reinforced plastic boxes, and these eight shielded PET modules were integrated in between the eight elements of a 270-mm-diameter and 280-mm-axial-length cylindrical birdcage RF coil, which was designed to be used with a 3-T clinical MRI system. The diameter of the PET scintillators with a 12-mm axial field-of-view became 255mm, which was very close to the imaging region. In this study, we have investigated the effects of this PET/RF-coil integrated system on the performance of MRI, which include the evaluation of static field (Bo) inhomogeneity, RF field (B1) distribution, local specific absorption rate (SAR) distribution, average SAR, and signal-to-noise ratio (SNR). For the central 170-mm-diameter and 80-mm-axial-length of a homogenous cylindrical phantom (with the total diameter of 200mm and axial-length of 100mm), an increase of about a maximum of 3µT in the Bo inhomogeneity was found, both in the central and 40-mm off-centered transverse planes, and a 5 percentage point increase of B1 field inhomogeneity was observed in the central transverse plane (from 84% without PET to 79% with PET), while B1 homogeneity along the coronal plane was almost unchanged (77%) following the integration of PET with the RF head coil. The average SAR and maximum local SAR were increased by 1.21 and 1.62 times, respectively. However, the SNR study for both spin-echo and gradient-echo sequences showed a reduction of about 70% and 60%, respectively, because of the shielded PET modules. The overall results prove the feasibility of this integrated PET/RF-coil system for using with the existing MRI system.

16.
J Magn Reson ; 245: 1-11, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24908640

RESUMO

We performed a new coupled circuit numerical simulation of eddy currents in an open compact magnetic resonance imaging (MRI) system. Following the coupled circuit approach, the conducting structures were divided into subdomains along the length (or width) and the thickness, and by implementing coupled circuit concepts we have simulated transient responses of eddy currents for subdomains in different locations. We implemented the Eigen matrix technique to solve the network of coupled differential equations to speed up our simulation program. On the other hand, to compute the coupling relations between the biplanar gradient coil and any other conducting structure, we implemented the solid angle form of Ampere's law. We have also calculated the solid angle for three dimensions to compute inductive couplings in any subdomain of the conducting structures. Details of the temporal and spatial distribution of the eddy currents were then implemented in the secondary magnetic field calculation by the Biot-Savart law. In a desktop computer (Programming platform: Wolfram Mathematica 8.0®, Processor: Intel(R) Core(TM)2 Duo E7500 @ 2.93GHz; OS: Windows 7 Professional; Memory (RAM): 4.00GB), it took less than 3min to simulate the entire calculation of eddy currents and fields, and approximately 6min for X-gradient coil. The results are given in the time-space domain for both the direct and the cross-terms of the eddy current magnetic fields generated by the Z-gradient coil. We have also conducted free induction decay (FID) experiments of eddy fields using a nuclear magnetic resonance (NMR) probe to verify our simulation results. The simulation results were found to be in good agreement with the experimental results. In this study we have also conducted simulations for transient and spatial responses of secondary magnetic field induced by X-gradient coil. Our approach is fast and has much less computational complexity than the conventional electromagnetic numerical simulation methods.

17.
J Clin Diagn Res ; 6(10): 1681-4, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23373027

RESUMO

OBJECTIVES: COPD is one of the major public health problems worldwide. Theophylline has been used in the treatment of COPD for decades. Doxofylline a new theophylline congener has been claimed to have better safety profile. The study was undertaken to compare theophylline and doxophylline at doses recommended and commonly used in clinical practice. METHODS: The study was conducted in patients of COPD in TB chest department of a medical college hospital. It was randomized, prospective and open label. A total of 154 patients were divided in two group .Group I was administered 400 mg theophylline SR once daily and group II was administered doxofylline 400 mg twice a day orally. Spirometric variables symptom score, and adverse effects were recorded on day 0, 7 and 21 of therapy. Data were compared and analysed using SPSS version 16. RESULTS: Results of the study showed that there was no statistically significant difference with respect to spirometric variables and symptom score in the two groups and there was no significant difference in two groups with respect to side effects (p>0.05). CONCLUSIONS: It is concluded that doxophylline has no advantage over theophylline in terms of either efficacy or safety on the doses commonly used in current clinical practice.