Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Cardiovasc Med ; 11: 1332152, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38357517

RESUMO

Background: Axillary arterial access (AAA) in pediatric heart catheterizations is undervalued. Methods: We retrospectively reviewed children with congenital heart diseases (CHDs) who received trans-axillary arterial catheterizations between January 2019 and February 2023. We aimed ultrasound-guided punctures in the proximal two-thirds of axillary arteries with diameters ≥2 mm to insert 7 cm/4 Fr short introducers. We administrated intra-arterial verapamil (1.25 mg) and heparin (100 UI/kg). We infiltrated per-operatively 2% lignocaine (10 mg) for arterial spasms, long sheaths use (≥5 Fr), and ≥60 min procedures in <3 kg patients. Results: We identified 30 patients (66.7% males) with a median age of 1.1 months (IQR, 0.3-5.4), and a median weight of 3.1 kg (IQR, 2.7-3.7). 5/30 patients had six redo interventions after a median of 3.9 months (IQR, 1.7-5.1). Overall, 27/36 procedures were interventional, including 6 aortic valvuloplasties, 6 balloon angioplasties, and 15 stenting procedures. The median arterial axillary angiographic diameter was 2.6 mm (IQR, 2.4-3). Access was right-sided in 23/36 (63.9%) procedures and obtained using 21G/2.5 cm bevel needles in 25/36 (69.4%) procedures. No hemodynamical change occurred after introducing spasmolytic drugs. The median fluoroscopy time was 26.1 min (IQR, 19.2-34.8). There were two self-resolving arterial dissections, one sub-occlusive arterial thrombosis (resolved with 6 weeks of enoxaparin), and one occlusive arterial thrombosis (resolved with alteplase thrombolysis and 6 weeks of enoxaparin). Median follow-up was 11.7 months (IQR, 8-17.5). Four patients with complex univentricular hearts died from non-procedural causes at a median of 40 days (IQR, 31-161) postoperative. Conclusion: Systematic approach for AAA is the key to success and unlocks the many potentials of trans-axillary pediatric cardiology interventions.

2.
Front Cardiovasc Med ; 10: 1322787, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38111890

RESUMO

Background: SwiftNINJA (Merit Medical Systems, USA) is a novel steerable microcatheter intended for coronary and peripheral vascular interventions. We evaluate and report the first use of SwiftNINJA in pediatric catheterization of congenital heart defects (CHDs). Methods: We performed a retrospective clinical data review of children with CHDs in whom SwiftNINJA was used during cardiac catheterization between April 2022 and June 2023. Utility, application, and standard safety were described comprehensively. Results: We identified 19 patients (78.9% males) with a median age of 5.3 months (IQR, 2-13.9), and a median weight of 5.3 kg (IQR, 4-7.7). 36.8% of the catheterizations were transarterial and 78.9% were interventional. SwiftNINJA was applied upfront in 3/19 patients to cannulate precisely the right pulmonary artery and eliminate the risk of dislocating a freshly implanted left pulmonary flow restrictor. In 16/19 patients, SwiftNINJA was applied after a median of 5 (IQR, 5-7) failed catheterization attempts using various combinations of catheters, microcatheters, and wires to cannulate challenging vasculature in seven, engage the lumen of stented vessels in five, cross complex aortic valve stenosis in three, and cross an apical ventricular septal defect in one patient with Damus-Kaye-Stansel repair. After the SwiftNINJA application, catheterization was done from the first attempt in 12/16 patients and from the second attempt in 4/16 patients. The median applied tip angulation was 90 degrees (IQR, 85-95). All procedures were completed successfully. No device malfunction or adverse events occurred. Conclusions: SwiftNINJA is a valuable addition for selective catheterization of challenging vasculatures or valvular anatomies in children with CHDs.

3.
Cardiol Young ; 33(12): 2654-2656, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37622316

RESUMO

Atrioseptostomy balloon catheter is an essential item to have on our shelves. However, the recall and shortage in production of the commonly used balloon atrioseptostomy catheters posed an imminent threat to our patients. Herein, we present the case of a newborn with a post-natal diagnosis of simple transposition of great arteries and restrictive atrial communication where repeated static balloon atrial septostomy using a 9 mm x 20 mm Sterling balloon failed to improve his status. We had to improvise per-operatively a new bespoke technique to perform a vital pull-through balloon atrial septostomy. The distal third of a 10 mm x 20 mm semi-compliant Cristal balloon was exteriorised out the tip of a 6-Fr 55 cm Cook Flexor sheath in the left atrium, and both were simultaneously pulled back to the right atrium to create an 8 mm septal defect. The procedure was successful without any complications. The baby was weaned off prostaglandin on day 3 and surgically repaired on day 5 with excellent results.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Comunicação Interatrial , Transposição dos Grandes Vasos , Lactente , Recém-Nascido , Humanos , Comunicação Interatrial/cirurgia , Átrios do Coração/cirurgia , Pericardiectomia , Catéteres
4.
Front Cardiovasc Med ; 10: 1150579, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37492157

RESUMO

Background: The development of microvascular plugs (MVPs) has enabled novel transcatheter deliverable endoluminal pulmonary flow restrictors (PFRs) with the potential to treat newborns and infants with life-threatening congenital heart diseases (CHDs) in a minimally invasive manner. We present our experience to evaluate the efficacy of this concept in controlling pulmonary blood flow in various CHDs. Methods: Retrospective clinical data review of patients with CHD and pulmonary over-circulation who received bilateral PFRs percutaneously. Results: Twenty-eight PFRs (7 MVP-5Q, 12 MVP-7Q, and 9 MVP-9Q) were finally implanted in 14 patients with a median age of 1.6 months (IQR, 0.9-2.3) and a median weight of 3.1 Kg (IQR, 2.7-3.6). Nine patients had large intra-cardiac left-to-right shunts (including 3 with fatal trisomy and palliative programs), 2 had borderline left ventricles, 2 had Taussig-Bing anomaly, and one had a hypoplastic left heart. Four patients had concomitant ductal stenting. Two MVP-5Qs were snare-removed and upsized to MVP-7Q. Patients experienced a significant drop in oxygen saturation and Qp/Qs. All patients were discharged from the ICU after a median of 3.5 days (IQR, 2-5.8) postoperative. Five patients had routine inter-stage catheterization and no device embolization or pulmonary branch distortion was seen. Fourteen (50%) PFRs were surgically explanted uneventfully on a median of 4.3 months (IQR, 1.2-6) post-implantation during biventricular repair in 6 patients and stage-2 palliation in one patient. The latter died 1 month post-operative from severe sepsis. Four patients are scheduled for surgical PFR removal and biventricular repair. Two patients with trisomy 18 died at 1 and 6.8 months post-procedure from non-cardiac causes. One patient with trisomy 13 is alive at 2.7 months post-procedure. Conclusion: It is feasible to bespoke MVPs and implant them as effective PFRs in various CHDs. This approach enables staged left ventricular recruitment, comprehensive stage-2 or biventricular repair with lower risk by postponing surgeries to later infancy. Device explantation is uneventful, and the outcomes afterward are promising.

5.
Catheter Cardiovasc Interv ; 101(1): 131-134, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36413609

RESUMO

Bioresorbable scaffolds (BRS) have been advocated as the fourth revolution in interventional cardiology medical devices with promising technology to improve the treatment of coronary artery disease with an event-free future. We describe the first reported use and early collapse of the Magmaris® Resorbable Magnesium Scaffold (RMS) stent (BIOTRONIK AG, Switzerland) to relieve left pulmonary artery severe stenosis in a newborn after the Norwood procedure. The stent collapse was detected 2 weeks after implantation and urgently treated with a balloon-expandable stent. This complication raises the alarm about the need to keep implanted RMS under scrutiny. The possibility of faster scaffold resorption in small babies or lack of sufficient radial force of RMS to resist acute vessel recoil has led to ineffective relief of branch pulmonary artery stenosis and failure to enable a safe short-term bridge to Stage II palliation.


Assuntos
Implantes Absorvíveis , Doença da Artéria Coronariana , Recém-Nascido , Humanos , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento , Stents , Doença da Artéria Coronariana/terapia , Magnésio , Desenho de Prótese
6.
J Card Surg ; 37(11): 3932-3934, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36087004

RESUMO

A 12-day-old girl underwent extended end-to-end aortic arch reconstruction with proximal pulmonary autograft patch augmentation on moderately hypothermic cardiopulmonary bypass. At the end of the procedure, the right superior pulmonary vein developed a severe stenosis at the insertion site of the left atrial vent, as a consequence of multiple hemostatic sutures. We report the successful intraoperative ad hoc application of the sutureless pericardial marsupialization technique for the herewith described severe, isolated, iatrogenic pulmonary vein stenosis in a neonate.


Assuntos
Hemostáticos , Veias Pulmonares , Estenose de Veia Pulmonar , Autoenxertos , Feminino , Humanos , Doença Iatrogênica , Recém-Nascido , Veias Pulmonares/cirurgia , Transplante Autólogo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...