Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neurointervention ; 19(2): 74-81, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38632689

RESUMO

PURPOSE: We report our initial experience with endovascular embolization of intracranial aneurysms using this new self-expanding open-cell stent system (pEGASUS stent system) with the antithrombogenic hydrophilic polymer coating. MATERIALS AND METHODS: We retrospectively reviewed all patients treated with stent-assisted coiling or the Woven EndoBridge device using the pEGASUS stent system between September 2022 and June 2023. Demographic, clinical, and angiographic data were analyzed as well as short-term follow-up, including procedural complication rates and aneurysmal occlusion rates using the Raymond-Roy occlusion classification (RROC). RESULTS: Twelve patients with 12 wide-necked intracranial aneurysms were treated with the pEGASUS stent system, including 2 acutely ruptured aneurysms embolized in an emergency setting. The treated aneurysms were located at the anterior communicating artery (25.0%), the basilar artery (50.0%), the middle cerebral artery (16.7%), and the internal carotid artery (8.3%). All stents were deployed successfully. Immediate complete aneurysmal occlusion (RROC class I) was achieved in 83.3% (10/12) and near-complete occlusion (RROC II) in 16.7% (2/12). No periprocedural complications occurred in patients treated in the elective setting. A single case of intraoperative in-stent thrombus formation occurred during the treatment of an acutely ruptured basilar aneurysm and was resolved with intravenous Tirofiban. No other periprocedural complications occurred. Eleven out of 12 patients were available for follow up (mean 7.4 months). Complete aneurysmal occlusion without in-stent stenosis (ISS) was seen in 10 patients (90.9%). One patient (9.1%) showed aneurysmal reperfusion (RROC IIIb) with asymptomatic moderate ISS. CONCLUSION: Our initial results demonstrate that the pEGASUS stent system appears to be a safe and effective device for stent assisted embolization of wide-necked intracranial aneurysms. More data is necessary to evaluate long-term follow-up.

2.
AJNR Am J Neuroradiol ; 45(6): 731-736, 2024 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-38290739

RESUMO

BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system has established itself as a safe and effective option for managing wide-neck bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB-sizing methods has proved ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach that involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Of these, 20 cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining 5 cases that did not follow the proposed sizing method were less favorable (P < .05). Among these, 4 cases treated with undersized WEBs showed neck remnants during follow-up, and 1 patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended.


Assuntos
Embolização Terapêutica , Aneurisma Intracraniano , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Embolização Terapêutica/instrumentação , Embolização Terapêutica/métodos , Adulto , Resultado do Tratamento , Angiografia Cerebral
3.
Cleve Clin J Med ; 84(3): 202-206, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28322675

RESUMO

Pregnant women with acute viral hepatitis are at higher risk of morbidity and death than pregnant women with chronic viral hepatitis. The risk of death is highest with acute viral hepatitis E, and the rate of transmission to the baby may be highest with hepatitis B virus (HBV) infection. Managing viral hepatitis in pregnancy requires assessing the risk of transmission to the baby, determining the gestational age at the time of infection and the mother's risk of decompensation, and understanding the side effects of antiviral drugs.


Assuntos
Antivirais/uso terapêutico , Hepatite Viral Humana/tratamento farmacológico , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Complicações Infecciosas na Gravidez/tratamento farmacológico , Feminino , Idade Gestacional , Hepatite Viral Humana/transmissão , Hepatite Viral Humana/virologia , Humanos , Gravidez , Complicações Infecciosas na Gravidez/virologia , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...