Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Acta Cardiol ; 73(2): 109-114, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28826332

RESUMO

Prosthetic valve endocarditis (PVE) is a serious infection with potentially fatal consequences. Early detection is crucial for successful management and outcome. The diagnosis of PVE is challenging and is based on the Duke criteria (DC) in which echocardiography plays a crucial role. However, transthoracic and transoesophageal echocardiography have less diagnostic value in PVE compared to native valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission is a new technique providing improved diagnostic accuracy in PVE. This paper presents a case and reviews on the role of positron emission tomography/computed tomography in PVE.


Assuntos
Bioprótese/efeitos adversos , Endocardite Bacteriana/diagnóstico , Próteses Valvulares Cardíacas/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/diagnóstico , Infecções Estafilocócicas/diagnóstico , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Bioprótese/microbiologia , Endocardite Bacteriana/microbiologia , Evolução Fatal , Feminino , Próteses Valvulares Cardíacas/microbiologia , Humanos , Infecções Relacionadas à Prótese/microbiologia , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação
2.
Nucl Med Commun ; 37(11): 1125-35, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27383191

RESUMO

OBJECTIVE: There are two distinct approaches for the assessment of left ventricular (LV) dyssynchrony by myocardial perfusion scintigraphy (MPS). The aim of this study was to compare the performance of the count-based and geometrical approach in clinical data using gated single photon emission computed tomography MPS. MATERIAL AND METHODS: Group 1 consisted of 113 patients (49 men, 64 women) with normal perfusion [summed rest score (SRS)≤3], normal LV ejection fraction (≥55%), and normal QRS duration (QRSd<120 ms). Group 2 consisted of 89 heart failure patients (79 men, 10 women) with no restriction for SRS, LV ejection fraction ≤35%, and QRSd ≥120 ms. All MPS parameters were obtained from the software Corridor4DM. Dyssynchrony parameters used were time to peak contraction, SD, and bandwidth (BW). RESULTS: SD and BW were estimated higher (difference group 1: SD 3.0±2.3 and BW 11.3±9.3, P-values <0.001; difference group 2: SD 2.4±4.3 and BW 1.3±17.0, P-value <0.001 and 0.479 respectively) using the count-based approach in comparison with the geometrical method. A significant and good correlation was found between these two methods (R=0.763, 0.902, 0.896 for time to peak contraction, SD, and BW respectively, P-values ≤0.001). SD and BW in both approaches were equally good parameters for differentiating heart failure patients (area under the curve: 0.995-0.998), although using different cut-off values. CONCLUSION: The count-based approach generally provides a wider phase distribution and subsequently greater SD and BW estimates compared with the geometrical algorithm. These differences result in clinically relevant deviations in normal and cut-off values that have to be recognized when evaluating patients.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Algoritmos , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos , Volume Sistólico , Disfunção Ventricular Esquerda/fisiopatologia
3.
Eur J Nucl Med Mol Imaging ; 43(2): 326-332, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26515715

RESUMO

PURPOSE: The aim of this study was to investigate whether performing the late cardiac (123)I-metaiodobenzylguanidine (MIBG) scan earlier than 4 h post-injection (p.i.) has relevant impact on the late heart to mediastinum ratio (H/M ratio) in patients with heart failure (HF). METHODS: Forty-nine patients with HF (median left ventricular ejection fraction of 31 %, 51 % ischaemic HF) referred for cardiac (123)I-MIBG scintigraphy were scanned at 15 min (early) p.i. and at 1, 2, 3 and 4 h (late) p.i. of (123)I-MIBG. Late H/M ratios were calculated and evaluated using a linear mixed model with the mean late H/M ratio at 4 h p.i. as a reference. A difference in late H/M ratios of more than 0.10 between the different acquisition times in comparison with the late H/M ratio at 4 h p.i. was considered as clinically relevant. RESULTS: Statistically significant mean differences were observed between the late H/M ratios at 1, 2 and 3 h p.i. compared with the late H/M ratio at 4 h p.i. (0.09, 0.05 and 0.02, respectively). However, the mean differences did not exceed the cut-off value of 0.10. On an individual patient level, compared to the late H/M ratio at 4 h p.i., the late H/M ratios at 1, 2 and 3 h p.i. differed more than 0.10 in 24 (50 %), 9 (19 %) and 2 (4 %) patients, respectively. CONCLUSION: Variation in acquisition time of (123)I-MIBG between 2 and 4 h p.i. does not lead to a clinically significant change in the late H/M ratio. An earlier acquisition time seems to be justified and may warrant a more time-efficient cardiac (123)I-MIBG imaging protocol.


Assuntos
3-Iodobenzilguanidina/administração & dosagem , Insuficiência Cardíaca/diagnóstico por imagem , Coração/diagnóstico por imagem , Mediastino/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Adolescente , Adulto , Idoso , Esquema de Medicação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
PLoS One ; 10(3): e0120184, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25793762

RESUMO

INTRODUCTION: Patients with differentiated thyroid cancer (DTC) are treated with (near)-total thyroidectomy followed by remnant ablation. Optimal radioiodine-131 (131I) uptake is achieved by withholding thyroid hormone (THW), pretreatment with recombinant human Thyrotropin Stimulating Hormone (rhTSH) is an alternative. Six randomized trials have been published comparing THW and rhTSH, however comparison is difficult because an uniform definition of ablation success is lacking. Using a strict definition, we performed an observational study aiming to determine the efficacy of rhTSH as preparation for remnant ablation. PATIENTS AND METHODS: Adult DTC patients with, tumor stage T1b to T3, Nx, N0 and N1, M0 were included in a prospective multicenter observational study with a fully sequential design, using a stopping rule. All patients received remnant ablation with 131I using rhTSH. Ablation success was defined as no visible uptake in the original thyroid bed on a rhTSH stimulated 150 MBq 131I whole body scan (WBS) 9 months after remnant ablation, or no visible uptake in the original thyroid bed on a post therapeutic WBS when a second high dose was necessary. RESULTS: After interim analysis of the first 8 patients, the failure rate was estimated to be 69% (90% confidence interval (CI) 20-86%) and the inclusion of new patients had to be stopped. Final analysis resulted in an ablation success in 11 out of 17 patients (65%, 95% CI 38-86%). CONCLUSION: According to this study, the efficacy of rhTSH in the preparation of 131I ablation therapy is inferior, when using a strict definition of ablation success. The current lack of agreement as to the definition of successful remnant ablation, makes comparison between different ablation strategies difficult. Our results point to the need for an international consensus on the definition of ablation success, not only in routine patient's care but also for scientific reasons. TRIAL REGISTRATION: Dutch Trial Registration NTR2395.


Assuntos
Neoplasias da Glândula Tireoide/cirurgia , Tireotropina/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto , Tireoglobulina/metabolismo , Glândula Tireoide/patologia , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/patologia , Tireoidectomia , Resultado do Tratamento
5.
Int J Cardiol ; 175(3): 539-44, 2014 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-25023791

RESUMO

BACKGROUND: We previously showed that intramyocardial bone marrow cell (BMC) injection in patients with refractory angina and chronic myocardial ischemia improves myocardial perfusion, cardiac function and disease-related complaints. Treatment effect varied between patients, but the predictors of response remain to be identified. Therefore, the aim of the present study was to assess whether patient characteristics, procedural data and baseline measurements influence the response to intramyocardial BMC treatment in a large cohort of refractory angina patients. METHODS AND RESULTS: In 120 patients (64 ± 9 years, 88% men) with refractory angina, 97 ± 13 × 10(6) BMCs were injected intramyocardially in regions with stress-inducible ischemia as assessed by single photon emission computed tomography (SPECT). Canadian Cardiovascular Society angina (CCS) class, quality-of-life score, exercise testing, SPECT and magnetic resonance imaging were performed at baseline and at 3 months follow-up demonstrating significant improvements in CCS class, quality-of-life, exercise capacity, myocardial perfusion and left ventricular function (all variables P<0.001). Multivariate analysis was performed to evaluate the influence of patient characteristics, procedural data and baseline measurements on BMC treatment response. Based on the improvement of myocardial perfusion at stress, diabetes and a large number of ischemic segments at baseline were shown to be independently associated with a large response to BMC therapy. CONCLUSION: The present study demonstrates that diabetes and a large number of ischemic segments are predictors of a large response to intramyocardial BMC injection in refractory angina and chronic ischemia. Furthermore, the safety and efficacy results of previous trials are now confirmed in a larger study population.


Assuntos
Angina Pectoris/diagnóstico , Angina Pectoris/terapia , Transplante de Medula Óssea/métodos , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Idoso , Angina Pectoris/epidemiologia , Estudos de Coortes , Método Duplo-Cego , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/epidemiologia , Miocárdio/patologia , Valor Preditivo dos Testes , Resultado do Tratamento
6.
J Nucl Med ; 55(1): 50-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24337600

RESUMO

UNLABELLED: CT angiography (CTA) and SPECT myocardial perfusion imaging (MPI) are complementary imaging techniques to assess coronary artery disease (CAD). Spatial integration and combined visualization of SPECT MPI and CTA data may facilitate correlation of myocardial perfusion defects and subtending coronary arteries and thus offer additional diagnostic value over either stand-alone or side-by-side interpretation of the respective datasets from the 2 modalities. In this study, we investigated the additional diagnostic value of a software-based CTA/SPECT MPI image fusion system over conventional side-by-side analysis in patients with suspected CAD. METHODS: Seventeen symptomatic patients who underwent both CTA and SPECT MPI within a 90-d period were included in our study; 7 of them also underwent invasive coronary angiography (ICA). The potential benefits of the synchronized multimodal heart visualization (SMARTVis) system in assessing CAD were investigated through a case study involving 4 experts from 2 medical centers, in which we performed, first, a side-by-side analysis using structured CTA and SPECT reports and, second, an integrated analysis using the SMARTVis system in addition to the reports. RESULTS: The fused interpretation led to a more accurate diagnosis, reflected in an increase in the individual observers' sensitivity and specificity to correctly refer for invasive angiography eventually followed by revascularization. For the first, second, third, and fourth observers, the respective sensitivities improved from 50%, 60%, 80%, and 80% to 70%, 80%, 100%, and 90% and the respective specificities from 100%, 94%, 83%, and 83% to 100%, 100%, 94%, and 83%. Additionally, the interobserver diagnosis agreement increased from 74% to 84%. The improvement was primarily found in patients presenting with CAD in more vessels than the number of reported perfusion defects. CONCLUSION: Integrated analysis of cardiac CTA and SPECT MPI using the SMARTVis system results in an improved diagnostic performance.


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Tomografia Computadorizada por Raios X , Idoso , Feminino , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Perfusão , Estudos Retrospectivos , Sensibilidade e Especificidade , Software , Fatores de Tempo
7.
J Cardiovasc Transl Res ; 6(5): 816-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23982478

RESUMO

In experimental studies, mesenchymal stem cell (MSC) transplantation in acute myocardial infarction (AMI) models has been associated with enhanced neovascularization and myogenesis. Clinical data however, are scarce. Therefore, the present study evaluates the safety and feasibility of intramyocardial MSC injection in nine patients, shortly after AMI during short-term and 5-year follow-up. Periprocedural safety analysis demonstrated one transient ischemic attack. No other adverse events related to MSC treatment were observed during 5-year follow-up. Clinical events were compared to a nonrandomized control group comprising 45 matched controls. A 5-year event-free survival after MSC-treatment was comparable to controls (89 vs. 91 %, P = 0.87). Echocardiographic imaging for evaluation of left ventricular function demonstrated improvements up to 5 years after MSC treatment. These findings were not significantly different when compared to controls. The present safety and feasibility study suggest that intramyocardial injection of MSC in patients shortly after AMI is feasible and safe up to 5-year follow-up.


Assuntos
Proliferação de Células , Transplante de Células-Tronco Mesenquimais , Infarto do Miocárdio/cirurgia , Idoso , Separação Celular , Células Cultivadas , Intervalo Livre de Doença , Estudos de Viabilidade , Feminino , Humanos , Injeções , Estimativa de Kaplan-Meier , Masculino , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Transplante de Células-Tronco Mesenquimais/mortalidade , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/mortalidade , Infarto do Miocárdio/fisiopatologia , Intervenção Coronária Percutânea , Recuperação de Função Fisiológica , Fatores de Tempo , Transplante Autólogo , Resultado do Tratamento , Função Ventricular Esquerda
8.
Eur J Nucl Med Mol Imaging ; 40(8): 1171-80, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23715901

RESUMO

PURPOSE: Automated software tools have permitted more comprehensive, robust and reproducible quantification of coronary stenosis, plaque burden and plaque location of coronary computed tomography angiography (CTA) data. The association between these quantitative CTA (QCT) parameters and the presence of myocardial ischaemia has not been explored. The aim of the present investigation was to evaluate the association between QCT parameters of coronary artery lesions and the presence of myocardial ischaemia on gated myocardial perfusion single-photon emission CT (SPECT). METHODS: Included in the study were 40 patients (mean age 58.2 ± 10.9 years, 27 men) with known or suspected coronary artery disease (CAD) who had undergone multidetector row CTA and gated myocardial perfusion SPECT within 6 months. From the CTA datasets, vessel-based and lesion-based visual analyses were performed. Consecutively, lesion-based QCT was performed to assess plaque length, plaque burden, percentage lumen area stenosis and remodelling index. Subsequently, the presence of myocardial ischaemia was assessed using the summed difference score (SDS ≥2) on gated myocardial perfusion SPECT. RESULTS: Myocardial ischaemia was seen in 25 patients (62.5%) in 37 vascular territories. Quantitatively assessed significant stenosis and quantitatively assessed lesion length were independently associated with myocardial ischaemia (OR 7.72, 95% CI 2.41-24.7, p < 0.001, and OR 1.07, 95% CI 1.00-1.45, p = 0.032, respectively) after correcting for clinical variables and visually assessed significant stenosis. The addition of quantitatively assessed significant stenosis (χ(2) = 20.7) and lesion length (χ(2) = 26.0) to the clinical variables and the visual assessment (χ(2) = 5.9) had incremental value in the association with myocardial ischaemia. CONCLUSION: Coronary lesion length and quantitatively assessed significant stenosis were independently associated with myocardial ischaemia. Both quantitative parameters have incremental value over baseline variables and visually assessed significant stenosis. Potentially, QCT can refine assessment of CAD, which may be of potential use for identification of patients with myocardial ischaemia.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Doença da Artéria Coronariana/diagnóstico por imagem , Imagem de Perfusão do Miocárdio , Idoso , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Am Heart J ; 164(5): 771-8, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23137509

RESUMO

BACKGROUND: We recently demonstrated in a randomized, double-blind, placebo-controlled trial that intramyocardial bone marrow cell (BMC) injection is associated with improvements in myocardial perfusion and anginal symptoms in chronic myocardial ischemia patients. In the present study the results of the crossover phase of this trial, in which patients previously treated with placebo received autologous BMC injections are reported. This allows a unique intra-patient comparison on the effect of BMC versus placebo injection with elimination of patient-related confounding factors. METHODS: In 16 patients (14 male, 64 ± 10 years), who previously received intramyocardial placebo injections in the setting of a randomized trial, 100 × 10(6) BMC were injected using the NOGA-system. Canadian Cardiovascular Society angina score and quality of life were evaluated at baseline, 3 and 6 months. Tc-99m single photon emission computed tomography and magnetic resonance imaging were performed at baseline and 3 months to assess myocardial perfusion and left ventricular (LV) function. RESULTS: Canadian Cardiovascular Society score and quality of life improved significantly after BMC injection as compared to placebo (P = 0.01 and P = 0.02, respectively). Single photon emission computed tomography revealed a significant greater improvement (P = 0.03) in summed stress score after BMC injection as compared to placebo. LV end-systolic volume significantly decreased after BMC injection but not after placebo injection. LV end-diastolic volume and LV ejection fraction did not change. CONCLUSION: Intramyocardial BMC injection in patients with chronic myocardial ischemia who previously received intramyocardial placebo treatment resulted in significant improvement in angina symptoms and myocardial perfusion. These results confirm the outcome of our previously reported randomized trial.


Assuntos
Angina Pectoris/prevenção & controle , Células da Medula Óssea , Circulação Coronária , Leucócitos Mononucleares , Isquemia Miocárdica/terapia , Qualidade de Vida , Função Ventricular Esquerda , Idoso , Doença Crônica , Estudos Cross-Over , Feminino , Testes de Função Cardíaca , Humanos , Injeções , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/fisiopatologia , Miocárdio , Projetos de Pesquisa , Índice de Gravidade de Doença , Tomografia Computadorizada de Emissão de Fóton Único , Resultado do Tratamento
10.
Trials ; 13: 144, 2012 Aug 23.
Artigo em Inglês | MEDLINE | ID: mdl-22913492

RESUMO

BACKGROUND: Hepatocellular carcinoma is a primary malignant tumor of the liver that accounts for an important health problem worldwide. Only 10 to 15% of hepatocellular carcinoma patients are suitable candidates for treatment with curative intent, such as hepatic resection and liver transplantation. A majority of patients have locally advanced, liver restricted disease (Barcelona Clinic Liver Cancer (BCLC) staging system intermediate stage). Transarterial loco regional treatment modalities offer palliative treatment options for these patients; transarterial chemoembolization (TACE) is the current standard treatment. During TACE, a catheter is advanced into the branches of the hepatic artery supplying the tumor, and a combination of embolic material and chemotherapeutics is delivered through the catheter directly into the tumor. Yttrium-90 radioembolization ((90)Y-RE) involves the transarterial administration of minimally embolic microspheres loaded with Yttrium-90, a ß-emitting isotope, delivering selective internal radiation to the tumor. (90)Y-RE is increasingly used in clinical practice for treatment of intermediate stage hepatocellular carcinoma, but its efficacy has never been prospectively compared to that of the standard treatment (TACE). In this study, we describe the protocol of a multicenter randomized controlled trial aimed at comparing the effectiveness of TACE and (90)Y-RE for treatment of patients with unresectable (BCLC intermediate stage) hepatocellular carcinoma. METHODS/DESIGN: In this pragmatic randomized controlled trial, 140 patients with unresectable (BCLC intermediate stage) hepatocellular carcinoma, with Eastern Cooperative Oncology Group performance status 0 to 1 and Child-Pugh A to B will be randomly assigned to either (90)Y-RE or TACE with drug eluting beads. Patients assigned to (90)Y-RE will first receive a diagnostic angiography, followed by the actual transarterial treatment, which can be divided into two sessions in case of bilobar disease. Patients assigned to TACE will receive a maximum of three consecutive transarterial treatment sessions. Patients will undergo structural follow-up for a timeframe of two years post treatment. Post procedural magnetic resonance imaging (MRI) will be performed at one and three months post trial entry and at three-monthly intervals thereafter for two years to assess tumor response. Primary outcome will be time to progression. Secondary outcomes will be overall survival, tumor response according to the modified RECIST criteria, toxicities/adverse events, treatment related effect on total liver function, quality of life, treatment-related costs and cost-effectiveness. TRIAL REGISTRATION: NCT01381211.


Assuntos
Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica , Embolização Terapêutica/métodos , Artéria Hepática , Neoplasias Hepáticas/terapia , Compostos Radiofarmacêuticos/administração & dosagem , Projetos de Pesquisa , Radioisótopos de Ítrio/administração & dosagem , Carcinoma Hepatocelular/irrigação sanguínea , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Quimioembolização Terapêutica/mortalidade , Análise Custo-Benefício , Progressão da Doença , Embolização Terapêutica/efeitos adversos , Embolização Terapêutica/mortalidade , Custos de Cuidados de Saúde , Artéria Hepática/diagnóstico por imagem , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Imageamento por Ressonância Magnética , Microesferas , Países Baixos , Qualidade de Vida , Radiografia , Compostos Radiofarmacêuticos/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Radioisótopos de Ítrio/efeitos adversos
11.
Eur J Nucl Med Mol Imaging ; 39(10): 1599-608, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22790878

RESUMO

PURPOSE: Despite its high prognostic value, widespread clinical implementation of (123)I-meta-iodobenzylguanidine (MIBG) myocardial scintigraphy is hampered by a lack of validation and standardization. The purpose of this study was to assess the reliability of planar (123)I-MIBG myocardial scintigraphy in patients with heart failure (HF). METHODS: Planar myocardial MIBG images of 70 HF patients were analysed by two experienced and one inexperienced observer. The reproducibility of early and delayed heart-to-mediastinum (H/M) ratios, as well as washout rate (WR) calculated by two different methods, was assessed using the intraclass correlation coefficient (ICC) and the Bland-Altman analysis. In addition, a subanalysis in patients with a very low H/M ratio (delayed H/M ratio <1.4) was performed. The delayed H/M ratio was also assessed using fixed-size oval and circular cardiac regions of interest (ROI). RESULTS: Intra- and interobserver analyses and experienced versus inexperienced observer analysis showed excellent agreement for the measured early and delayed H/M ratios and WR on planar (123)I-MIBG images (the ICCs for the delayed H/M ratios were 0.98, 0.96 and 0.90, respectively). In addition, the WR without background correction resulted in higher reliability than the WR with background correction (the interobserver Bland-Altman 95 % limits of agreement were -2.50 to 2.16 and -10.10 to 10.14, respectively). Furthermore, the delayed H/M ratio measurements remained reliable in a subgroup of patients with a very low delayed H/M ratio (ICC 0.93 for the inter-observer analysis). Moreover, a fixed-size cardiac ROI could be used for the assessment of delayed H/M ratios, with good reliability of the measurement. CONCLUSION: The present study showed a high reliability of planar (123)I-MIBG myocardial scintigraphy in HF patients, confirming that MIBG myocardial scintigraphy can be implemented easily for clinical risk stratification in HF.


Assuntos
3-Iodobenzilguanidina , Insuficiência Cardíaca/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/normas , Compostos Radiofarmacêuticos , Idoso , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/normas , Feminino , Humanos , Masculino , Prognóstico , Reprodutibilidade dos Testes
12.
J Nucl Cardiol ; 19(4): 752-62, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22669736

RESUMO

BACKGROUND: Assessment of cardiac innervation using single-photon emission computer tomography (SPECT) is less established than planar imaging, but may be more suitable for quantification. Therefore, a volumetric quantification of I-123 MIBG SPECT acquisitions was performed. Reproducibility, the effects of extra cardiac I-123 MIBG uptake and the relation with conventional planar indices were evaluated. METHODS: 54 patients referred for planar and SPECT I-123 MIBG acquisitions were included. Ellipsoidal or box-shaped volumes of interest were placed on the left ventricle, cardiac lumen, mediastinum, lung and liver. SPECT segmentation was performed twice in all patients. Indices were determined based on the heart-to-mediastinum (HM), myocardial wall-to-mediastinum and myocardial wall-to-lumen regions. HM ratios and washout rates were also determined based on anterior planar images. RESULTS: Cardiac count densities were highly reproducible (CV 1.5-5.4, ICC 0.96-0.99) and inter-rater variability was low (CV 1.8-6.8, ICC 0.94-0.99). Mediastinal uptake was an important explanatory variable of uptake in the entire heart (early R(2) = 0.36; delayed R(2) =0.43) and myocardial wall (early R(2) = 0.28; delayed R(2) = 0.37). Lung washout was an explanatory variable of organ washout of the heart (heart R(2) = 0.38; myocardial wall R(2) = 0.33). In general, SPECT indices showed moderate-to-good correlations with the planar uptake (PCC 0.497-0.851). CONCLUSION: By applying a volumetric segmentation method we were able to segment the heart in all patients. SPECT I-123 MIBG quantification was found to be highly reproducible and had a moderate to good correlation with the planar indices.


Assuntos
3-Iodobenzilguanidina/farmacocinética , Coração/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Fatores Etários , Idoso , Feminino , Ventrículos do Coração/patologia , Humanos , Radioisótopos do Iodo/farmacologia , Masculino , Mediastino/patologia , Pessoa de Meia-Idade , Miocárdio/patologia , Variações Dependentes do Observador , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Distribuição Tecidual
13.
Eur J Nucl Med Mol Imaging ; 39(3): 421-9, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22113618

RESUMO

PURPOSE: Left ventricular dyssynchrony may predict response to cardiac resynchronization therapy and may well predict adverse cardiac events. Recently, a geometrical approach for dyssynchrony analysis of myocardial perfusion scintigraphy (MPS) was introduced. In this study the feasibility of this geometrical method to detect dyssynchrony was assessed in a population with a normal MPS and in patients with documented ventricular dyssynchrony. METHODS: For the normal population 80 patients (40 men and 40 women) with normal perfusion (summed stress score ≤2 and summed rest score ≤2) and function (left ventricular ejection fraction 55-80%) on MPS were selected; 24 heart failure patients with proven dyssynchrony on MRI were selected for comparison. All patients underwent a 2-day stress/rest MPS protocol. Perfusion, function and dyssynchrony parameters were obtained by the Corridor4DM software package (Version 6.1). RESULTS: For the normal population time to peak motion was 42.8 ± 5.1% RR cycle, SD of time to peak motion was 3.5 ± 1.4% RR cycle and bandwidth was 18.2 ± 6.0% RR cycle. No significant gender-related differences or differences between rest and post-stress acquisition were found for the dyssynchrony parameters. Discrepancies between the normal and abnormal populations were most profound for the mean wall motion (p value <0.001), SD of time to peak motion (p value <0.001) and bandwidth (p value <0.001). CONCLUSION: It is feasible to quantify ventricular dyssynchrony in MPS using the geometrical approach as implemented by Corridor4DM.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca/métodos , Imagem de Perfusão do Miocárdio/métodos , Disfunção Ventricular/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Descanso , Estudos Retrospectivos , Estresse Fisiológico , Disfunção Ventricular/fisiopatologia
14.
Eur J Nucl Med Mol Imaging ; 38(11): 2050-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21850500

RESUMO

PURPOSE: Vascular stiffness may potentially be used as a screening tool to identify asymptomatic patients with diabetes with abnormal myocardial perfusion. The purpose of this study was therefore to determine the association between vascular stiffness, measured in term of pulse wave velocity (PWV) and augmentation index (AIx), and abnormal myocardial perfusion imaging (MPI) in asymptomatic patients with diabetes. METHODS: Prospectively, 160 asymptomatic patients with diabetes (mean age 51 years, 87 men) underwent MPI with adenosine stress. The summed stress score (SSS) was determined in each patient according to a 17-segment and five-point score. Abnormal MPI (SSS ≥ 3) was classified as moderate (SSS 3-7) or severe (SSS ≥ 8) MPI defects. Using applanation tonometry, the carotid-femoral PWV and the radial AIx corrected to 75 beats per minute were determined noninvasively. RESULTS: MPI was abnormal in 61 patients (38%), with severe MPI defects in 22 patients (14%). Mean PWV increased with deteriorating MPI from 8.4 ± 2.2 m/s in normal MPI to 9.0 ± 2.2 m/s in moderate MPI defects (p = 0.11) and to 11.1 ± 2.5 m/s in severe MPI defects (p < 0.01). Likewise, mean AIx increased from 18.4 ± 13.4% to 19.4 ± 10.7% (p = 0.66) and to 25.4 ± 9.0% (p = 0.03). After adjustment for age and other risk factors, PWV remained a significant predictor of severe MPI defects (p = 0.01, OR 1.50, 95% CI 1.11-2.00), whereas AIx was no longer significant (p = 0.20). CONCLUSION: Vascular stiffness measured by PWV is associated with severe MPI defects in asymptomatic patients with diabetes.


Assuntos
Doenças Assintomáticas , Vasos Sanguíneos/patologia , Diabetes Mellitus/diagnóstico por imagem , Diabetes Mellitus/patologia , Fenômenos Mecânicos , Imagem de Perfusão do Miocárdio , Estresse Fisiológico , Fenômenos Biomecânicos , Vasos Sanguíneos/fisiopatologia , Diabetes Mellitus/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada de Emissão de Fóton Único
15.
Eur J Nucl Med Mol Imaging ; 38(11): 2031-9, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21850501

RESUMO

PURPOSE: The aim of the current study was to evaluate the feasibility of phase analysis on gated myocardial perfusion SPECT (GMPS) for the assessment of left ventricular (LV) diastolic dyssynchrony in a head-to-head comparison with tissue Doppler imaging (TDI). METHODS: The population consisted of patients with end-stage heart failure of New York Heart Association functional class III or IV with a reduced LV ejection fraction of ≤ 35%. LV diastolic dyssynchrony was calculated using TDI as the maximal time delay between early peak diastolic velocities of two opposing left ventricle walls (diastolic mechanical delay). Significant LV diastolic dyssynchrony was defined as a diastolic mechanical delay of >55 ms on TDI. Furthermore, phase analysis on GMPS was performed to evaluate LV diastolic dyssynchrony; diastolic phase standard deviation (SD) and histogram bandwidth (HBW) were used as markers of LV diastolic dyssynchrony. RESULTS: A total of 150 patients (114 men, mean age 66.0 ± 10.4 years) with end-stage heart failure were enrolled. Both diastolic phase SD (r = 0.81, p < 0.01) and diastolic HBW (r = 0.75, p < 0.01) showed good correlations with LV diastolic dyssynchrony on TDI. Additionally, patients with LV diastolic dyssynchrony on TDI (>55 ms) showed significantly larger diastolic phase SD (68.1 ± 13.4° vs. 40.7 ± 14.0°, p < 0.01) and diastolic HBW (230.6 ± 54.3° vs. 129.0 ± 55.6°, p < 0.01) as compared to patients without LV diastolic dyssynchrony on TDI (≤ 55 ms). Finally, phase analysis on GMPS showed a good intra- and interobserver reproducibility for the determination of diastolic phase SD (ICC 0.97 and 0.88) and diastolic HBW (ICC 0.98 and 0.93). CONCLUSION: Phase analysis on GMPS showed good correlations with TDI for the assessment of LV diastolic dyssynchrony.


Assuntos
Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Diástole/fisiologia , Imagem de Perfusão do Miocárdio , Ultrassonografia Doppler , Disfunção Ventricular Esquerda/diagnóstico por imagem , Idoso , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Retrospectivos , Sístole/fisiologia , Disfunção Ventricular Esquerda/patologia
16.
Eur J Nucl Med Mol Imaging ; 38(2): 230-8, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20953608

RESUMO

PURPOSE: The aim of the current study was to evaluate the relationship between the site of latest mechanical activation as assessed with gated myocardial perfusion SPECT (GMPS), left ventricular (LV) lead position and response to cardiac resynchronization therapy (CRT). METHODS: The patient population consisted of consecutive patients with advanced heart failure in whom CRT was currently indicated. Before implantation, 2-D echocardiography and GMPS were performed. The echocardiography was performed to assess LV end-systolic volume (LVESV), LV end-diastolic volume (LVEDV) and LV ejection fraction (LVEF). The site of latest mechanical activation was assessed by phase analysis of GMPS studies and related to LV lead position on fluoroscopy. Echocardiography was repeated after 6 months of CRT. CRT response was defined as a decrease of ≥15% in LVESV. RESULTS: Enrolled in the study were 90 patients (72% men, 67±10 years) with advanced heart failure. In 52 patients (58%), the LV lead was positioned at the site of latest mechanical activation (concordant), and in 38 patients (42%) the LV lead was positioned outside the site of latest mechanical activation (discordant). CRT response was significantly more often documented in patients with a concordant LV lead position than in patients with a discordant LV lead position (79% vs. 26%, p<0.01). After 6 months, patients with a concordant LV lead position showed significant improvement in LVEF, LVESV and LVEDV (p<0.05), whereas patients with a discordant LV lead position showed no significant improvement in these variables. CONCLUSION: Patients with a concordant LV lead position showed significant improvement in LV volumes and LV systolic function, whereas patients with a discordant LV lead position showed no significant improvements.


Assuntos
Terapia de Ressincronização Cardíaca/métodos , Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Imagem de Perfusão do Miocárdio , Idoso , Fenômenos Biomecânicos , Estudos de Viabilidade , Feminino , Seguimentos , Cardiopatias/diagnóstico por imagem , Cardiopatias/fisiopatologia , Cardiopatias/terapia , Humanos , Masculino , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...