Proc Inst Mech Eng H ; : 9544119211069472, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35147063

RESUMO

Total Hip Arthroplasty (THA) is one of the most common and successful surgical interventions. The survivorship at 10 years for the most commonly used systems is over 95%. However, the incidence of revision is usually much higher in the 0-1 year time period following the intervention. The most common reason for revision in this early time period is dislocation and subluxation, which may be defined as complete or permanent, and partial or temporary loss of contact between the bearing surfaces respectively. This study comprises the development of a geometric model of bone and an in situ total hip replacement, to predict the occurrence and location of bone and component impingement for a wide range of acetabular cup positions and for a series of frequently practiced activities of daily living. The model developed predicts that anterior-superior component impingement is associated with activities that result in posterior dislocation. The incidence may be reduced by increased cup anteversion and inclination. Posterior-inferior component impingement is associated with anterior dislocation activities. Its incidence may be reduced by decreased cup anteversion and inclination. A component impingement-free range was identified, running from when the cup was positioned with 45° inclination and 25° anteversion to 70° inclination and 15°-20° anteversion.

2.
J Biomech ; 95: 109296, 2019 Oct 11.
Artigo em Inglês | MEDLINE | ID: mdl-31431346

RESUMO

Patient imaging and explant analysis has shown evidence of edge loading of hard-on-hard hip replacements in vivo. Experimental hip simulator testing under edge loading conditions has produced increased, clinically-relevant, wear rates for hard-on-hard bearings when compared to concentric conditions. Such testing, however, is time consuming and costly. A quick running computational edge loading model (Python Edge Loading (PyEL) - quasi-static, rigid, frictionless), capable of considering realistic bearing geometries, was developed. The aim of this study was to produce predictions of separation within the typical experimental measurement error of ∼0.5 mm. The model was verified and validated against comparable finite element (FE) models (including inertia and friction) and pre-existing experimental test data for 56 cases, covering a variety of simulated cup orientations, positions, tissue tensions, and loading environments. The PyEL model agreed well with both the more complex computational modelling and experimental results. From comparison with the FE models, the assumption of no inertia had little effect on the maximum separation prediction. With high contact force cases, the assumption of no friction had a larger effect (up to ∼5% error). The PyEL model was able to predict the experimental maximum separations within ∼0.3 mm. It could therefore be used to optimise an experimental test plan and efficiently investigate a much wider range of scenarios and variables. It could also help explain trends and damage modes seen in experimental testing through identifying the contact locations on the liner that are not easily measured experimentally.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Teste de Materiais/métodos , Desenho de Prótese , Fenômenos Biomecânicos , Cerâmica , Simulação por Computador , Fricção , Humanos , Fenômenos Mecânicos , Rotação
3.
J Mech Behav Biomed Mater ; 98: 40-47, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31185443

RESUMO

Ceramic-on-ceramic bearings in total hip replacement have shown the potential to provide low wear solutions in hip replacement. Assessing the tribological performance of these materials is important to predict their long-term performance in patients. In this study, a methodology was devised to assess the tribological in vitro behaviour of composite ceramics under combined adverse edge loading conditions and accelerated ageing. Two commercial ceramic composites were considered, namely Alumina-Toughened Zirconia (ATZ, ceramys®) and Zirconia-Toughened Alumina (ZTA, symarec®). The bearing couples were studied using the Leeds Mark II hip joint simulator for a total of eight million cycles, the first two million under normal gait (no edge loading) and the following six million cycles with the addition of edge loading conditions driven by medial-lateral separation. The bearing couples underwent hydrothermal ageing using an accelerated protocol in autoclave every million cycles. The influence of edge loading combined with ageing was significant for ATZ bearings, resulting in a slower overall ageing kinetics over the wear stripe than on the control heads. During the autoclave ageing steps, the monoclinic fraction increased more over the wear stripe area than over the unworn area. Both results thus indicated that the monoclinic phase was removed during shocks induced by edge loading. The wear performance of the two materials were similar exhibiting relatively low wear rates and low level of microstructural damage for these clinically relevant adverse conditions.


Assuntos
Artroplastia de Quadril , Cerâmica , Óxido de Alumínio/química , Cerâmica/química , Marcha , Estresse Mecânico , Fatores de Tempo , Suporte de Carga , Zircônio/química
4.
J Biomed Mater Res B Appl Biomater ; 106(4): 1456-1462, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-28661563

RESUMO

Wear and fatigue of polyethylene acetabular cups have been reported to play a role in the failure of total hip replacements. Hip simulator testing under a wide range of clinically relevant loading conditions is important. Edge loading of hip replacements can occur following impingement under extreme activities and can also occur during normal gait, where there is an offset deficiency and/or joint laxity. This study evaluated a hip simulator method that assessed wear and damage in polyethylene acetabular liners that were subjected to edge loading. The liners tested to evaluate the method were a currently manufactured crosslinked polyethylene acetabular liner and an aged conventional polyethylene acetabular liner. The acetabular liners were tested for 5 million standard walking cycles and following this 5 million walking cycles with edge loading. Edge loading conditions represented a separation of the centers of rotation of the femoral head and the acetabular liner during the swing phase, leading to loading of the liner rim on heel strike. Rim damage and cracking was observed in the aged conventional polyethylene liner. Steady-state wear rates assessed gravimetrically were lower under edge loading compared to standard loading. This study supports previous clinical findings that edge loading may cause rim cracking in liners, where component positioning is suboptimal or where material degradation is present. The simulation method developed has the potential to be used in the future to test the effect of aging and different levels of severity of edge loading on a range of cross-linked polyethylene materials. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1456-1462, 2018.


Assuntos
Artroplastia de Quadril , Teste de Materiais/métodos , Polietileno , Desenho de Prótese , Acetábulo , Prótese de Quadril , Humanos , Propriedades de Superfície
5.
Proc Inst Mech Eng H ; 231(4): 299-306, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28332445

RESUMO

Variation in the surgical positioning of total hip replacement can result in edge loading of the femoral head on the rim of the acetabular cup. Previous work has reported the effect of edge loading on the wear of hip replacement bearings with a fixed level of dynamic biomechanical hip separation. Variations in both rotational and translational surgical positioning of the hip joint replacement combine to influence both the biomechanics and the tribology including the severity of edge loading, the amount of dynamic separation, the force acting on the rim of the cup and the resultant wear and torque acting on the cup. In this study, a virtual model of a hip joint simulator has been developed to predict the effect of variations in some surgical positioning (inclination and medial-lateral offset) on the level of dynamic separation and the contact force of the head acting on the rim as a measure of severity of edge loading. The level of dynamic separation and force acting on the rim increased with increased translational mismatch between the centres of the femoral head and the acetabular cup from 0 to 4 mm and with increased cup inclination angle from 45° to 65°. The virtual model closely replicated the dynamics of the experimental hip simulator previously reported, which showed similar dynamic biomechanical trends, with the highest level of separation being found with a mismatch of 4 mm between the centres of the femoral head and acetabular cup and 65° cup inclination angle.


Assuntos
Artroplastia de Quadril/instrumentação , Simulação por Computador , Rotação , Interface Usuário-Computador , Suporte de Carga
6.
J Biomed Mater Res B Appl Biomater ; 105(6): 1361-1368, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27062442

RESUMO

Ceramic composites have performed very well under adverse edge loading conditions when used in like-on-like configurations, where the femoral head and acetabular cup are of the same material. The aim of this study was to determine the wear of pure alumina (Al2 O3 ), alumina toughened zirconia (ATZ) and zirconia toughened alumina (ZTA) when used in mixed bearing combinations, under edge loading conditions due to translational mal-positioning. The head-on-cup configurations of three ceramic materials were ATZ-on-ZTA, ZTA-on-ATZ, Al2 O3 -on-ATZ, ATZ-on-Al2 O3 , Al2 O3 -on-ZTA, and ZTA-on-Al2 O3 . They were tested on the Leeds II hip simulator under microseparation conditions. The bedding in and steady state wear rates of ATZ-on-ZTA were 1.16mm3 /million cycles and 0.18mm3 /million, respectively, and for ATZ-on-Al2 O3 were 0.66 mm3 /million cycles and 0.20 mm3 /million, respectively. The wear rates of the other bearing combinations under these adverse microseparation conditions, Al2 O3 -on-ATZ, Al2 O3 -on-ZTA, ZTA-on-ATZ and ZTA-on-Al2 O3 were very low with no clear bedding in and steady state phases, and with steady state wear rates lower than 0.11 mm3 /million. The mixed material combinations tested in this study have shown slightly higher wear rates when compared to ATZ in like-on-like configuration reported previously, but superior wear resistance when compared to alumina-on-alumina bearings tested previously under the same adverse microseparation conditions. © 2016 The Authors Journal of Biomedical Materials Research Part B: Applied Biomaterials Published by Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1361-1368, 2017.


Assuntos
Artroplastia de Quadril , Cerâmica/química , Prótese de Quadril , Teste de Materiais , Humanos , Suporte de Carga
7.
Proc Inst Mech Eng H ; 230(5): 389-97, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27160559

RESUMO

Hip joint simulators are used extensively for preclinical testing of hip replacements. The variation in simulator design and test conditions used worldwide can affect the tribological performance of polyethylene. The aim of this study was to assess the effects of simulator mechanics and design on the wear and creep of ultra-high-molecular-weight polyethylene. In the first part of this study, an electromechanical simulator and pneumatic simulator were used to compare the wear and creep of metal-on-polyethylene components under the same standard gait conditions. In the second part of the study, the same electromechanical hip joint simulator was used to investigate the influence of kinematics on wear. Higher wear rates and penetration depths were observed from the electromechanical simulator compared with the pneumatic simulator. When adduction/abduction was introduced to the gait cycle, there was no significant difference in wear with that obtained under the gait cycle condition without adduction/abduction. This study confirmed the influence of hip simulator design and loading conditions on the wear of polyethylene, and therefore direct comparisons of absolute wear rates between different hip joint simulators should be avoided. This study also confirmed that the resulting wear path was the governing factor in obtaining clinically relevant wear rates, and this can be achieved with either two axes or three axes of rotations. However, three axes of rotation (with the inclusion of adduction/abduction) more closely replicate clinical conditions and should therefore be the design approach for newly developed hip joint simulators used for preclinical testing.


Assuntos
Análise de Falha de Equipamento/instrumentação , Prótese de Quadril , Teste de Materiais/instrumentação , Metais Pesados/química , Polietileno/química , Desenho de Equipamento , Análise de Falha de Equipamento/métodos , Humanos , Teste de Materiais/métodos , Modelos Biológicos
8.
Proc Inst Mech Eng H ; 228(7): 682-92, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24963036

RESUMO

Finite element models are becoming increasingly useful tools to conduct parametric analysis, design optimisation and pre-clinical testing for hip joint replacements. However, the verification of the finite element model is critically important. The purposes of this study were to develop a three-dimensional anatomic finite element model for a modular metal-on-polyethylene total hip replacement for predicting its contact mechanics and to conduct experimental validation for a simple finite element model which was simplified from the anatomic finite element model. An anatomic modular metal-on-polyethylene total hip replacement model (anatomic model) was first developed and then simplified with reasonable accuracy to a simple modular total hip replacement model (simplified model) for validation. The contact areas on the articulating surface of three polyethylene liners of modular metal-on-polyethylene total hip replacement bearings with different clearances were measured experimentally in the Leeds ProSim hip joint simulator under a series of loading conditions and different cup inclination angles. The contact areas predicted from the simplified model were then compared with that measured experimentally under the same conditions. The results showed that the simplification made for the anatomic model did not change the predictions of contact mechanics of the modular metal-on-polyethylene total hip replacement substantially (less than 12% for contact stresses and contact areas). Good agreements of contact areas between the finite element predictions from the simplified model and experimental measurements were obtained, with maximum difference of 14% across all conditions considered. This indicated that the simplification and assumptions made in the anatomic model were reasonable and the finite element predictions from the simplified model were valid.


Assuntos
Prótese de Quadril , Metais/química , Modelos Teóricos , Polietileno/química , Simulação por Computador , Análise de Falha de Equipamento , Análise de Elementos Finitos , Fricção , Desenho de Prótese , Estresse Mecânico , Propriedades de Superfície
9.
J Biomed Mater Res B Appl Biomater ; 101(8): 1456-62, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23744622

RESUMO

Further development of ceramic materials for total hip replacement aim to increase fracture toughness and further reduce the incidence of bearing fracture. Edge loading due to translational mal positioning (microseparation) has replicated stripe wear, wear rates, and bimodal wear debris observed on retrievals. This method has replicated the fracture of early zirconia ceramic-on-ceramic bearings. This has shown the necessity of introducing microseparation conditions to the gait cycle when assessing the tribological performance of new hip replacement bearings. Two novel ceramic matrix composite materials, zirconia-toughened alumina (ZTA) and alumina-toughened zirconia (ATZ), were developed by Mathys Orthopädie GmbH. In this study, ATZ-on-ATZ and ZTA-on-ZTA bearing combinations were tested and compared with alumina-on-alumina (Al2O3-on-Al2O3) bearings under adverse microseparation and edge loading conditions using the Leeds II physiological anatomical hip joint simulator. The wear rate (±95% confidence limit) of ZTA-on-ZTA was 0.14 ± 0.10 mm(3)/million cycles and that of ATZ-on-ATZ was 0.06 ± 0.004 mm(3)/million cycles compared with a wear rate of 0.74 ± 1.73 mm(3)/million cycles for Al2O3-on-Al2O3 bearings. Stripe wear was evident on all bearing combinations; however, the stripe formed on the ATZ and ZTA femoral heads was thinner and shallower that that formed on the Al2O3 heads. Posttest phase composition measurements for both ATZ and ZTA materials showed no significant change in the monoclinic zirconia content. ATZ-on-ATZ and ZTA-on-ZTA showed superior wear resistance properties when compared with Al2O3-on-Al2O3 under adverse edge loading conditions.


Assuntos
Artroplastia de Quadril/instrumentação , Materiais Biocompatíveis/química , Cerâmica/química , Prótese de Quadril , Óxido de Alumínio/química , Animais , Bovinos , Análise de Falha de Equipamento/métodos , Articulação do Quadril/patologia , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície , Zircônio/química
10.
Proc Inst Mech Eng H ; 227(5): 535-42, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23637263

RESUMO

Ceramic-on-ceramic bearings have become of great interest due to the substantial improvements in the manufacturing techniques and material properties and due to polyethylene wear debris-induced osteolysis and the issues with metal wear debris and ion release by metal-on-metal bearings. Edge loading conditions due to translational malpositioning (microseparation conditions) have been shown to replicate clinically relevant wear mechanisms and increase the wear of ceramic-on-ceramic bearings; thus, it was necessary to test new bearing materials and designs under these adverse conditions. The aim of this study was to assess the effect of increasing head size on the wear of BIOLOX(®) delta ceramic-on-ceramic bearings under edge loading conditions due to rotational (steep cup inclination angle) and translational (microseparation) malpositioning. In this study, six 36-mm ceramic-on-ceramic bearings (BIOLOX delta, CeramTec, Germany) were tested under standard and edge loading conditions using the Leeds II hip simulator and compared to the 28-mm bearings tested and published previously under identical conditions. The mean wear rate under standard gait conditions was below 0.1 mm(3)/million cycles for both the 28-mm and the 36-mm ceramic-on-ceramic bearings, and increasing the inclination angle did not affect the wear rates. The introduction of microseparation to the gait cycle increased the wear rate of ceramic-on-ceramic bearing and resulted in stripe wear on the femoral heads. Under microseparation conditions, the wear rate of size 36-mm bearings (0.22 mm(3)/million cycles) was significantly higher (p = 0.004) than that for size 28-mm bearings (0.13 mm(3)/million cycles). This was due to the larger contact area for the larger bearings and deprived lubrication under edge loading conditions. The wear rate of BIOLOX delta ceramic-on-ceramic bearings under microseparation conditions was still very low (<0.25 mm(3)/million cycles) compared to earlier generation ceramic-on-ceramic bearings (BIOLOX forte, 1.84 mm(3)/million cycles) and other bearing materials such as metal-on-metal bearings (2-8 mm(3)/million cycles).


Assuntos
Acetábulo/fisiologia , Cerâmica/química , Fêmur/fisiologia , Prótese de Quadril , Modelos Biológicos , Suporte de Carga , Acetábulo/química , Acetábulo/cirurgia , Simulação por Computador , Desenho Assistido por Computador , Módulo de Elasticidade/fisiologia , Análise de Falha de Equipamento , Fêmur/química , Fêmur/cirurgia , Fricção/fisiologia , Humanos , Hidrodinâmica , Lubrificação/métodos , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície
11.
J Biomed Mater Res B Appl Biomater ; 101(5): 770-5, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23359608

RESUMO

Ceramic-on-metal (COM) hip replacements, where the head is BIOLOX® Delta ceramic and the liner is CoCrMo alloy, have demonstrated reduced wear under standard simulator conditions compared to metal-on-metal (MOM) bearings. COM hips are now being used clinically around the world. MOM hip resurfacings have raised concerns regarding poor clinical performance and increased in vivo wear was associated with steeply inclined acetabular components and translationally malpositioned components. The aim of this study was to compare the wear rates of MOM and COM total hip prostheses under adverse edge-loading conditions in a hip simulator test. COM and MOM 36 mm hip prostheses were tested in a hip simulator, with liners mounted to provide a clinical inclination angle of 55°. A simplified gait cycle and microseparation conditions were applied for two million cycles in 25% new born calf serum. The overall mean volumetric wear rate of COM bearings under adverse conditions was 0.36 ± 0.55 mm³/million cycles; this was significantly less than MOM wear (1.32 ± 0.91 mm³/million cycles). Under these adverse conditions; the contact zone on the head intersects the rim of the cup causing substantially elevated contact stresses, disrupting the protective boundary and mixed lubrication regime causing changes in types and severity of wear mechanisms. In COM bearings, the harder head does not become damaged when there is lubricant starvation and wear does not accelerate. In conclusion, COM bearings showed reduced wear compared to MOM bearings under standard and adverse clinically relevant simulator conditions and COM bearings may provide an advantage over MOM bearings under edge-loading conditions clinically.


Assuntos
Cerâmica , Prótese de Quadril , Falha de Prótese , Vitálio , Materiais Biocompatíveis , Análise de Falha de Equipamento/instrumentação , Análise de Falha de Equipamento/métodos , Prótese de Quadril/efeitos adversos , Humanos , Lubrificantes , Teste de Materiais , Desenho de Prótese/efeitos adversos , Propriedades de Superfície
12.
J Biomed Mater Res B Appl Biomater ; 101(2): 213-22, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23281164

RESUMO

Metal-on-metal (MoM) bearings have shown low-wear rates under standard hip simulator conditions; however, retrieval studies have shown large variations in wear rates and mechanisms. High-wear in vivo has caused catastrophic complications and has been associated with steep cup-inclination angle (rotational malpositioning). However, increasing the cup-inclination angle in vitro has not replicated the increases in wear to the same extent as those observed in retrievals. Clinically relevant wear rates, patterns, and particles were observed in vitro for ceramic-on-ceramic bearings when microseparation (translational malpositioning) conditions were introduced into the gait cycle. In the present study, 28 and 36-mm MoM bearings were investigated under adverse conditions. Increasing the cup angle from 45° to 65° resulted in a significant increase in the wear rate of the 28 mm bearings. However, for the 36 mm bearings, head-rim contact did not occur under the steep cup-angle condition, and the wear rate did not increase. The introduction of microseparation to the gait cycle significantly increased the wear rate of the MoM bearings. Cup angle and head size did not influence the wear rate under microseparation conditions. This study indicated that high-in vivo wear rates were associated with edge loading due to rotational malpositioning such as high-cup-inclination angle and translational malpositioning that could occur due to several surgical factors. Translational malpositioning had a more dominant effect on the wear rate. Preclinical simulation testing should be undertaken with translational and rotational malpositioning conditions as well as standard walking cycle conditions defined by the ISO standard.


Assuntos
Cabeça do Fêmur/patologia , Cabeça do Fêmur/cirurgia , Prótese de Quadril , Fenômenos Biomecânicos , Análise de Falha de Equipamento , Marcha/fisiologia , Prótese de Quadril/efeitos adversos , Humanos , Teste de Materiais , Metais , Desenho de Prótese , Falha de Prótese , Propriedades de Superfície , Suporte de Carga/fisiologia
13.
Orthop Trauma ; 26(4): 246-252, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23335949

RESUMO

A new Stratified Approach For Enhanced Reliability (SAFER) pre-clinical simulation testing of joint prostheses is presented in this article. The aim of this approach is preclinical systematic testing of wear performance in the much wider envelope of conditions found clinically rather than relying only on the standard testing conditions that are currently used. The approach includes variations in surgical delivery, variations in kinematics, variations in the patient population and degradation of the biomaterial properties. Clinical experience of existing prostheses has been used to validate the new in vitro methods.

14.
Orthop Trauma ; 26(4): 253-258, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23335950

RESUMO

A new Stratified Approach For Enhanced Reliability (SAFER) pre-clinical simulation testing of joint prostheses has been described in a preceding paper in this volume. The application of SAFER in vitro simulation and testing to metal-on-metal bearings is described in this review paper. The review aims to provide further understanding of the reasons for, and causes of, increased wear in metal-on-metal hips in a proportion of patients. Variation in positioning (mal-positioning) of the head and cup in hip prostheses results in the head contacting the rim of the cup and producing increased wear. Variation in both translational and rotational positioning has been investigated. Variation in translational positioning of the centres of the head and cup, which is not detected on radiographs, is a frequent occurrence clinically and can result in a substantial increase in wear rate. The variation in translational positioning acts synergistically with variation in rotational positioning to produce substantial increases in wear. These recent findings are consistent with the wear mechanisms and formation of stripe wear reported for ceramic-on-ceramic bearings over a decade ago, and provide insight into the reasons for the variation and increases in the wear rate found clinically in metal-on-metal hips in specific patients, which may cause premature failure.

15.
J Biomed Mater Res B Appl Biomater ; 95(2): 263-8, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20860044

RESUMO

Ceramic-on-ceramic (CoC) bearings in total hip replacements (THRs) have shown low wear volumes under standard gait in hip simulator studies. However, clinical reports have indicated variations in wear rates and formation of stripe-like wear area on the ceramic femoral heads. The aim of this study was to investigate the influence of cup inclination angle and microseparation on the wear of CoC bearings in THRs. The six station Leeds II Physiological Anatomical Joint Simulator was used to investigate the wear of 28 mm diameter alumina matrix composite ceramic bearings (BIOLOX® delta). It was shown that increasing the cup inclination angle from 55° to 65° had no significant effect on the wear rate of BIOLOX® delta CoC under both standard gait and microseparation conditions in this in vitro study. Under standard gait conditions, the mean wear rate for both cup inclination angle conditions was very low at 0.05 mm(3)/million cycles. The introduction of microseparation to the standard gait cycle increased the mean wear rates to 0.13 mm(3)/million cycles for the cup inclination angle of 55° and 0.11 mm(3)/million cycles for that of 65°. The level of increased wear with microseparation was not dependent on cup angle. A stripe of wear on the head also formed, with corresponding superior rim wear on the cup. The wear rates obtained were low compared to the HIPed third generation alumina ceramic (BIOLOX® forte) tested under the same adverse conditions (1.84 mm(3)/million cycles). BIOLOX® delta has shown lower wear than previous ceramic materials used in THR under adverse conditions.


Assuntos
Artroplastia de Quadril , Cerâmica , Teste de Materiais , Fluoroscopia , Modelos Teóricos , Propriedades de Superfície