Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
J Nucl Cardiol ; 23(3): 414-21, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26002814

RESUMO

BACKGROUND: Cardiac CT is a non-invasive modality with the ability to estimate LVEF. However, given its limited temporal resolution and radiation, there has been initial resistance to use CT to measure LVEF. Developing an accurate, fast, low radiation dose protocol is desirable. OBJECTIVE: The objective of this study is to demonstrate that a 'low radiation dose' 64 slice cardiac computed tomography (CT) protocol is feasible and can accurately measure left ventricular ejection fraction (LVEF) while delivering a radiation dose lower than radionuclide angiography (RNA). METHODS: Patients undergoing RNA were prospectively screened and enrolled to undergo a 'low-dose' 64 slice CT LVEF protocol. LVEF measures, duration of each study and radiation dose between CT and RNA were compared. RESULTS: A total of 77 patients (mean age = 61.8 ± 12.2 years and 58 men) were analyzed. The mean LVEF measured by CT and RNA were 41.9 ± 15.2% and 39.4 ± 13.9%, respectively, (P = 0.154) with a good correlation (r = 0.863). Bland-Altman plot revealed a good agreement between the CT and RNA LVEF (mean difference of -2.4). There was good agreement between CT LVEF and RNA for identifying patients with LVEF ≤30% (kappa = 0.693) and LVEF ≥50% (kappa = 0.749). The mean dose estimated effective dose for CT and RNA were 4.7 ± 1.6 and 9.5 ± 1.0 mSv, respectively. The mean CT LVEF imaging duration (4:32 ± 3:05 minutes) was significantly shorter than the RNA image acquisition time (9:05 ± 2:36 minutes; p < 0.001). CONCLUSION: The results of our study suggest that low-dose CT LVEF protocol is feasible, accurate, and fast while delivering a lower radiation dose than traditional RNA.


Assuntos
Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Angiografia Cintilográfica/métodos , Volume Sistólico , Tomografia Computadorizada por Raios X/métodos , Disfunção Ventricular Esquerda/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Med Phys ; 41(10): 102501, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281976

RESUMO

PURPOSE: Myocardial perfusion imaging (MPI) is used for diagnosis and prognosis of coronary artery disease. When MPI studies are performed with positron emission tomography (PET) and the radioactive tracer rubidium-82 chloride ((82)Rb), a small but non-negligible fraction of studies (∼10%) suffer from extracardiac interference: high levels of tracer uptake in structures adjacent to the heart which mask the true cardiac tracer uptake. At present, there are no clinically available options for automated detection or correction of this problem. This work presents an algorithm that detects and classifies the severity of extracardiac interference in (82)Rb PET MPI images and reports the accuracy and failure rate of the method. METHODS: A set of 200 (82)Rb PET MPI images were reviewed by a trained nuclear cardiologist and interference severity reported on a four-class scale, from absent to severe. An automated algorithm was developed that compares uptake at the external border of the myocardium to three thresholds, separating the four interference severity classes. A minimum area of interference was required, and the search region was limited to that facing the stomach wall and spleen. Maximizing concordance (Cohen's Kappa) and minimizing failure rate for the set of 200 clinician-read images were used to find the optimal population-based constants defining search limit and minimum area parameters and the thresholds for the algorithm. Tenfold stratified cross-validation was used to find optimal thresholds and report accuracy measures (sensitivity, specificity, and Kappa). RESULTS: The algorithm was capable of detecting interference with a mean [95% confidence interval] sensitivity/specificity/Kappa of 0.97 [0.94, 1.00]/0.82 [0.66, 0.98]/0.79 [0.65, 0.92], and a failure rate of 1.0% ± 0.2%. The four-class overall Kappa was 0.72 [0.64, 0.81]. Separation of mild versus moderate-or-greater interference was performed with good accuracy (sensitivity/specificity/Kappa = 0.92 [0.86, 0.99]/0.86 [0.71, 1.00]/0.78 [0.64, 0.92]), while separation of moderate versus severe interference severity classes showed reduced sensitivity/Kappa but little change in specificity (sensitivity/specificity/Kappa = 0.83 [0.77, 0.88]/0.82 [0.77, 0.88]/0.65 [0.60, 0.70]). Specificity was greater than sensitivity for all interference classes. Algorithm execution time was <1 min. CONCLUSIONS: The algorithm produced here has a low failure rate and high accuracy for detection of extracardiac interference in (82)Rb PET MPI scans. It provides a fast, reliable, automated method for assessing severity of extracardiac interference.


Assuntos
Cloretos , Imagem de Perfusão do Miocárdio/métodos , Reconhecimento Automatizado de Padrão/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Radioisótopos de Rubídio , Rubídio , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Bases de Dados Factuais , Feminino , Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...