Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Neuroradiol ; 40(1): 38-44, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22633044

RESUMO

OBJECTIVES: Carotid angioplasty with stenting (CAS) in patients with carotid stenosis (CS) has become more restricted in France especially since the disclosure of such studies as EVA-3S and Stent-supported percutaneous angioplasty of the carotid artery versus endarterectomy (SPACE). This report is of a series of CS cases contraindicated for endarterectomy that underwent CAS at a French center of interventional neuroradiology. PATIENTS AND METHODS: Fifty-five patients with symptomatic CS more than 60% consecutively submitted to CAS between September 2008 and February 2011. The primary endpoint was either death or stroke within 30 days of the procedure; a secondary goal was to identify any possible factors that might have influenced the success and outcome of the intervention. RESULTS: The overall periprocedural stroke/death rate at 30 days was 5.4% (three out of 55 patients), with three non-disabling strokes and no deaths. Twenty-seven patients (49.1%) were treated with a cerebral protection device (CPD). Stent placement was achieved in all cases. Open- and closed-cell stents were implanted in 40 (72.7%) and 15 procedures (27.3%), respectively. Neither the use of a CPD, the carotid stent cell design nor any anatomical or technical factors were associated with a lower risk of stroke or death within 30 days of CAS. CONCLUSION: CAS in symptomatic patients with CS contraindicated for endarterectomy in this selected French series proved feasible and safe, with acceptable levels of morbidity. Use of a CPD, type of stent (open- or closed-cell), and anatomical and technical factors had no influence on the success of the procedure or the outcome within 30 days of the operation.


Assuntos
Angioplastia/instrumentação , Angioplastia/mortalidade , Prótese Vascular/estatística & dados numéricos , Estenose das Carótidas/mortalidade , Estenose das Carótidas/cirurgia , Dispositivos de Proteção Embólica/estatística & dados numéricos , Stents/estatística & dados numéricos , Idoso , Estenose das Carótidas/diagnóstico por imagem , Feminino , França/epidemiologia , Humanos , Masculino , Prevalência , Radiografia , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
2.
Interv Neuroradiol ; 18(3): 284-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22958766

RESUMO

The balloon remodeling technique (BRT) was designed for endovascular treatment of wide-necked intracranial aneurysms. To date, the balloon catheters available have had a single lumen and suitable guidewires ranging from 0.010 to 0.012 inches. We describe the first case of aneurysm embolization using the BRT with the new double-lumen balloon catheter, Scepter C(®), navigable on a 0.014-inch wire, and discuss the benefit of such a device.


Assuntos
Oclusão com Balão/instrumentação , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...