RESUMO
OBJECTIVES: Carotid angioplasty with stenting (CAS) in patients with carotid stenosis (CS) has become more restricted in France especially since the disclosure of such studies as EVA-3S and Stent-supported percutaneous angioplasty of the carotid artery versus endarterectomy (SPACE). This report is of a series of CS cases contraindicated for endarterectomy that underwent CAS at a French center of interventional neuroradiology. PATIENTS AND METHODS: Fifty-five patients with symptomatic CS more than 60% consecutively submitted to CAS between September 2008 and February 2011. The primary endpoint was either death or stroke within 30 days of the procedure; a secondary goal was to identify any possible factors that might have influenced the success and outcome of the intervention. RESULTS: The overall periprocedural stroke/death rate at 30 days was 5.4% (three out of 55 patients), with three non-disabling strokes and no deaths. Twenty-seven patients (49.1%) were treated with a cerebral protection device (CPD). Stent placement was achieved in all cases. Open- and closed-cell stents were implanted in 40 (72.7%) and 15 procedures (27.3%), respectively. Neither the use of a CPD, the carotid stent cell design nor any anatomical or technical factors were associated with a lower risk of stroke or death within 30 days of CAS. CONCLUSION: CAS in symptomatic patients with CS contraindicated for endarterectomy in this selected French series proved feasible and safe, with acceptable levels of morbidity. Use of a CPD, type of stent (open- or closed-cell), and anatomical and technical factors had no influence on the success of the procedure or the outcome within 30 days of the operation.
Assuntos
Angioplastia/instrumentação , Angioplastia/mortalidade , Prótese Vascular/estatística & dados numéricos , Estenose das Carótidas/mortalidade , Estenose das Carótidas/cirurgia , Dispositivos de Proteção Embólica/estatística & dados numéricos , Stents/estatística & dados numéricos , Idoso , Estenose das Carótidas/diagnóstico por imagem , Feminino , França/epidemiologia , Humanos , Masculino , Prevalência , Radiografia , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do TratamentoRESUMO
The balloon remodeling technique (BRT) was designed for endovascular treatment of wide-necked intracranial aneurysms. To date, the balloon catheters available have had a single lumen and suitable guidewires ranging from 0.010 to 0.012 inches. We describe the first case of aneurysm embolization using the BRT with the new double-lumen balloon catheter, Scepter C(®), navigable on a 0.014-inch wire, and discuss the benefit of such a device.
Assuntos
Oclusão com Balão/instrumentação , Embolização Terapêutica/instrumentação , Aneurisma Intracraniano/terapia , Angiografia Cerebral , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Resultado do TratamentoRESUMO
Embolization of head and neck hypervascular tumors is a well-established therapeutic technique. Preoperative embolization reduces intraoperative blood loss, shortens the length of surgery, and decreases surgical morbility and mortality. This study assesses the safety and efficacy of preoperative embolization of meningiomas fed by the OPH by using Onyx liquid embolic agent.