1.
Sensors (Basel) ; 24(4)2024 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-38400453

RESUMO

The leakage of gases and chemical vapors is a common accident in laboratory processes that requires a rapid response to avoid harmful effects if humans and instruments are exposed to this leakage. In this paper, the performance of a portable sensor node designed for integration with mobile and stationary robots used to transport chemical samples in automated laboratories was tested and evaluated. The sensor node has four main layers for executing several functions, such as power management, control and data preprocessing, sensing gases and environmental parameters, and communication and data transmission. The responses of three metal oxide semiconductor sensors, BME680, ENS160, and SGP41, integrated into the sensing layer have been recorded for various volumes of selected chemicals and volatile organic compounds, including ammonia, pentane, tetrahydrofuran, butanol, phenol, xylene, benzene, ethanol, methanol, acetone, toluene, and isopropanol. For mobile applications, the sensor node was attached to a sample holder on a mobile robot (ASTI ProBOT L). In addition, the sensor nodes were positioned close to automation systems, including stationary robots. The experimental results revealed that the tested sensors have a different response to the tested volumes and can be used efficiently for hazardous gas leakage detection and monitoring.

2.
Sensors (Basel) ; 22(21)2022 Oct 25.
Artigo em Inglês | MEDLINE | ID: mdl-36365859

RESUMO

Air pollution and leakages of hazardous and toxic gases and chemicals are among the dangers that frequently occur at automated chemical and life science laboratories. This type of accident needs to be processed as soon as possible to avoid the harmful side effects that can happen when a human is exposed. Nitrogen oxides and volatile organic compounds are among the most prominent indoor air pollutants, which greatly affect the lifestyles in these places. In this study, a commercial MOX gas sensor, SGP41, was embedded in an IoT environmental sensor node for hazardous gas detection and alarm. The sensor can detect several parameters, including nitrogen oxide index (NOx-Index) and volatile organic compound index (VOC-Index). Several tests were conducted to detect the leakage of nitrogen oxides and volatile organic compounds in different concentrations and volumes, as well as from different leakage distances, to measure the effect of these factors on the response speed and recovery time of the sensors used. These factors were also compared between the different sensors built into the sensor node to give a comprehensive picture of the system used. The system testing results revealed that the SGP41 sensor is capable of implementing the design purposes for the target parameters, can detect a small NO2 gas leakage starting from 0.3% volume, and can detect all the tested VOC solvents ≥ 100 µL.


Assuntos
Poluentes Atmosféricos , Disciplinas das Ciências Biológicas , Compostos Orgânicos Voláteis , Humanos , Compostos Orgânicos Voláteis/análise , Laboratórios , Poluentes Atmosféricos/análise , Gases , Óxidos de Nitrogênio , Monitoramento Ambiental/métodos
3.
Sensors (Basel) ; 22(4)2022 Feb 14.
Artigo em Inglês | MEDLINE | ID: mdl-35214376

RESUMO

The measurement of air quality parameters for indoor environments is of increasing importance to provide sufficient safety conditions for workers, especially in places including dangerous chemicals and materials such as laboratories, factories, and industrial locations. Indoor air quality index (IAQ-index) and total volatile organic Compounds (TVOC) are two important parameters to measure air impurities or air pollution. Both parameters are widely used in gases sensing applications. In this paper, the IAQ-index and TVOCs have been investigated to identify the best and most flexible solution for air quality threshold selection of hazardous/toxic gases detection and alarming systems. The TVOCs from the SGP30 gas sensor and the IAQ-index from the SGP40 gas sensor were tested with 12 different organic solvents. The two gas sensors are combined with an IoT-based microcontroller for data acquisition and data transfer to an IoT-cloud for further processing, storing, and monitoring purposes. Extensive tests of both sensors were carried out to determine the minimum detectable volume depending on the distance between the sensor node and the leakage source. The test scenarios included static tests in a classical chemical hood, as well as tests with a mobile robot in an automated sample preparation laboratory with different positions.


Assuntos
Poluentes Atmosféricos , Poluição do Ar em Ambientes Fechados , Compostos Orgânicos Voláteis , Poluentes Atmosféricos/análise , Poluição do Ar em Ambientes Fechados/análise , Monitoramento Ambiental , Gases , Humanos , Laboratórios , Compostos Orgânicos Voláteis/análise
4.
Sensors (Basel) ; 21(23)2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34884132

RESUMO

The leakage of hazardous gases and chemical vapors is considered one of the dangerous accidents that can occur in laboratories, workshops, warehouses, and industrial sites that use or store these substances. The early detection and alarming of hazardous gases and volatile chemicals are significant to keep the safety conditions for the people and life forms who are work in and live around these places. In this paper, we investigate the available mobile detection and alarming systems for toxic, hazardous gases and volatile chemicals, especially in the laboratory environment. We included papers from January 2010 to August 2021 which may have the newest used sensors technologies and system components. We identified (236) papers from Clarivate Web of Science (WoS), IEEE, ACM Library, Scopus, and PubMed. Paper selection has been done based on a fast screening of the title and abstract, then a full-text reading was applied to filter the selected papers that resulted in (42) eligible papers. The main goal of this work is to discuss the available mobile hazardous gas detection and alarming systems based on several technical details such as the used gas detection technology (simple element, integrated, smart, etc.), sensor manufacturing technology (catalytic bead, MEMS, MOX, etc.) the sensor specifications (warm-up time, lifetime, response time, precision, etc.), processor type (microprocessor, microcontroller, PLC, etc.), and type of the used communication technology (Bluetooth/BLE, Wi-Fi/RF, ZigBee/XBee, LoRa, etc.). In this review, attention will be focused on the improvement of the detection and alarming system of hazardous gases with the latest invention in sensors, processors, communication, and battery technologies.


Assuntos
Gases , Laboratórios , Humanos
5.
Sensors (Basel) ; 21(21)2021 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-34770653

RESUMO

In recent years the degree of automation in life science laboratories increased considerably by introducing stationary and mobile robots. This trend requires intensified considerations of the occupational safety for cooperating humans, since the robots operate with low volatile compounds that partially emit hazardous vapors, which especially do arise if accidents or leakages occur. For the fast detection of such or similar situations a modular IoT-sensor node was developed. The sensor node consists of four hardware layers, which can be configured individually regarding basic functionality and measured parameters for varying application focuses. In this paper the sensor node is equipped with two gas sensors (BME688, SGP30) for a continuous TVOC measurement. In investigations under controlled laboratory conditions the general sensors' behavior regarding different VOCs and varying installation conditions are performed. In practical investigations the sensor node's integration into simple laboratory applications using stationary and mobile robots is shown and examined. The investigation results show that the selected sensors are suitable for the early detection of solvent vapors in life science laboratories. The sensor response and thus the system's applicability depends on the used compounds, the distance between sensor node and vapor source as well as the speed of the automation systems.


Assuntos
Disciplinas das Ciências Biológicas , Robótica , Gases , Humanos , Solventes