Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Simul Healthc ; 10(3): 146-53, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25844702

RESUMO

INTRODUCTION: Patient safety during emergency department procedural sedation (EDPS) can be difficult to study. Investigators sought to delineate and experimentally assess EDPS performance and safety practices of senior-level emergency medicine residents through in situ simulation. METHODS: Study sessions used 2 pilot-tested EDPS scenarios with critical action checklists, institutional forms, embedded probes, and situational awareness questionnaires. An experimental informatics system was separately developed for bedside EDPS process guidance. Postgraduate year 3 and 4 subjects completed both scenarios in randomized order; only experimental subjects were provided with the experimental system during second scenarios. RESULTS: Twenty-four residents were recruited into a control group (n = 12; 6.2 ± 7.4 live EDPS experience) and experimental group (n = 12; 11.3 ± 8.2 live EDPS experience [P = 0.10]). Critical actions for EDPS medication selection, induction, and adverse event recognition with resuscitation were correctly performed by most subjects. Presedation evaluations, sedation rescue preparation, equipment checks, time-outs, and documentation were frequently missed. Time-outs and postsedation assessments increased during second scenarios in the experimental group. Emergency department procedural sedation safety probe detection did not change across scenarios in either group. Situational awareness scores were 51% ± 7% for control group and 58% ± 12% for experimental group. Subjects using the experimental system completed more time-outs and scored higher Simulation EDPS Safety Composite Scores, although without comprehensive improvements in EDPS practice or safety. CONCLUSIONS: Study simulations delineated EDPS and assessed safety behaviors in senior emergency medicine residents, who exhibited the requisite medical knowledge base and procedural skill set but lacked some nontechnical skills that pertain to emergency department microsystem functions and patient safety. The experimental system exhibited limited impact only on in-simulation time-out compliance.


Assuntos
Serviço Hospitalar de Emergência/organização & administração , Hipnóticos e Sedativos/administração & dosagem , Internato e Residência/organização & administração , Ressuscitação/métodos , Treinamento por Simulação/organização & administração , Adulto , Lista de Checagem , Tomada de Decisões , Feminino , Humanos , Masculino , Segurança do Paciente
2.
Simul Healthc ; 8(4): 242-52, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23842118

RESUMO

INTRODUCTION: Cardiopulmonary resuscitation (CPR) instructor/coordinator (CPR-I/C) adherence to published guidelines during resuscitation and learner assessment for basic life support (BLS)/CPR skills has not been experimentally studied. Investigators sought to (1) determine the quality of CPR-I/C chest compression and the accuracy of CPR-I/C chest compression assessment, and (2) improve CPR-I/C compression and assessment skills through cardiac arrest simulations with objective in-scenario performance feedback. METHODS: Thirty CPR-I/Cs (median, 20 years [range, 4-40 years] of BLS provider experience; 6 years [range 1-40 years] of BLS instructor experience) were randomized to control or experimental group. Each subject performed compressions during a 2-minute simulation, then reviewed 6 videos of simulated CPR performances (featuring prespecified chest compression parameters) for scoring as "pass" or "needs remediation." Subjects participated in a second simulation with or without real-time manikin compression feedback, then reviewed 6 additional videos. Primary outcome variables were the proportion of subjects with more than 80% (American Heart Association regional criteria) or more than 23 of 30 (ie, 77%; American Heart Association instructor manual criteria) correct compressions and subjects' accuracy of "pass"/"needs remediation" assessment for videos. The secondary outcome variable was correlation between subjects' correctness of chest compressions and their assessment accuracy for simulated CPR compression performance. RESULTS: All CPR-I/C subjects compressed suboptimally at baseline; real-time manikin feedback improved the proportion of subjects with more than 77% correct compressions to 0.53 (P < 0.01). Video review data revealed persistently low CPR-I/C assessment accuracy. Correlation between subjects' correctness of compressions and their assessment accuracy remained poor regardless of interventions. CONCLUSIONS: Real-time compression feedback during simulation improved CPR-I/C's chest compression performance skills without comparable improvement in chest compression assessment skills.


Assuntos
Reanimação Cardiopulmonar/educação , Competência Clínica , Simulação por Computador , Docentes , Manequins , Adulto , Reanimação Cardiopulmonar/normas , Retroalimentação , Feminino , Humanos , Masculino , Estudos Prospectivos
3.
BMJ Qual Saf ; 22(1): 72-83, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23060389

RESUMO

BACKGROUND AND OBJECTIVES: Medical simulation and human factors engineering (HFE) may help investigate and improve clinical telemetry systems. Investigators sought to (1) determine the baseline performance characteristics of an Emergency Department (ED) telemetry system implementation at detecting simulated arrhythmias and (2) improve system performance through HFE-based intervention. METHODS: The prospective study was conducted in a regional referral ED over three 2-week periods from 2010 to 2012. Subjects were clinical providers working at the time of unannounced simulation sessions. Three-minute episodes of sinus bradycardia (SB) and of ventricular tachycardia (VT) were simulated. An experimental HFE-based multi-element intervention was developed to (1) improve system accessibility, (2) increase system relevance and utility for ED clinical practice and (3) establish organisational processes for system maintenance and user base cultivation. The primary outcome variable was overall simulated arrhythmia detection. Pre-intervention system characterisation, post-intervention end-user feedback and real-world correlates of system performance were secondary outcome measures. RESULTS: Baseline HFE assessment revealed limited accessibility, suboptimal usability, poor utility and general neglect of the telemetry system; one simulated VT episode (5%) was detected during 20 pre-intervention sessions. Systems testing during intervention implementation recorded detection of 4 out of 10 arrhythmia simulations (p=0.03). Twenty post-intervention sessions revealed more VT detections (8 of 10) than SB detections (3 of 10) for a 55% overall simulated arrhythmia detection rate (p=0.001). CONCLUSIONS: Experimental investigations helped reveal and mitigate weaknesses in an ED clinical telemetry system implementation. In situ simulation and HFE methodologies can facilitate the assessment and abatement of patient safety hazards in healthcare environments.


Assuntos
Arritmias Cardíacas/diagnóstico , Ergonomia , Arquitetura Hospitalar , Sistemas de Informação Hospitalar/estatística & dados numéricos , Simulação de Paciente , Melhoria de Qualidade , Telemetria , Arritmias Cardíacas/terapia , Serviço Hospitalar de Emergência , Humanos
4.
J Contin Educ Nurs ; 44(2): 59-63; quiz 64-5, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23230856

RESUMO

The goal of the development phase of the CPR Instructor Real-time Review through Use of Simulation (CIRRUS) research program was to create a video library portraying a spectrum of objectively verified simulation chest compression performances. Investigators scripted and recorded 12 two-person cardiopulmonary resuscitation (CPR) videos with specific chest compression parameters encompassing a range of hand positions, rates, depths, and chest releases in combinations that proportionately reflected typical learner cohort performances. Six videos were designated to portray adequate chest compressions, whereas the other six videos were to feature inadequate compressions. All 12 final 2-minute videos showed chest compression parameters as originally specified within tolerances to comply with American Heart Association recommendations. Deviations from specification were 1 to 10 cpm (mode = 4 cpm) for compression rate and -1.4 to 1.3 cm (mode = 0.9 cm) for depth. The program's collection of simulated CPR videos with objectively verified chest compression performances may help researchers and educators study and improve CPR instruction and provider preparation for the effective delivery of optimal patient care.


Assuntos
Reanimação Cardiopulmonar/educação , Educação Continuada em Enfermagem/métodos , Simulação de Paciente , Desenvolvimento de Pessoal/métodos , Gravação em Vídeo/métodos , Adulto , Reanimação Cardiopulmonar/métodos , Feminino , Humanos , Masculino , Recursos Humanos de Enfermagem Hospitalar/educação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...