Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
BJR Open ; 3(1): 20210020, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34877454

RESUMO

OBJECTIVE: Diagnostic reference levels (DRLs) for CT part of positron emission tomography-CT (PET-CT) examinations are limited. The study was aiming to execute the second phase of the national DRL in support of optimisation and dose reduction in State of KW. METHODS: In this multicentre collaborative PET-CT study, oncology patient data were exclusively collected due to the National MOH Ethical Committee recommendation and limitation of the other studies. Median, Mean, SD, 75th, 25th percentiles as well as whole body (WB) effective dose (ED) were calculated. The study was UK-IPEM-based methodology and it was the second phase of the study in Kuwait. RESULTS: Half body (HB) and WB scans were 65 and 35% of the total enterers (309). The third quartile dose-length product (DLP) (mGy x cm) and volumetric CT dose index (mGy) values for the HB (537, 5) were higher than the UK NDRL (400, 4.3) but were lower than the Swiss NDRL (620, 6) and the France NDRL (762, 7.7). Comparatively, the proposed NDRLs for the WB (684, 4.1) were lower than Swiss National Data (720, 5.0) though, the Swiss had about 5000 (HB) & 706 (WB), the UK had 370 (HB) and France had 1000 (HB) entries. Calculated ED varied from 4.1 to 10.2 mSv, (mean values = 6.9 mSv) for HB and from 2.6 to 7 mSv (mean value = 4.6 mSv). CONCLUSIONS: There was 9.1% improvement in NDRL for 2019, compared to 2018, but there is a continuous need for improving NDRL. ADVANCES IN KNOWLEDGE: Data provided a trend of NDRL that is served as a national data bank for continuous optimisation.

2.
Medicine (Baltimore) ; 98(4): e14207, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30681596

RESUMO

Many discrepancy in selection of proper filter and its parameters for individual cases exists. The authors investigate the impact of the most common filters on patient NM images with coronary artery disease (CAD), and compare the results with the computerized tomography (CT)-Angio and angiography for accuracy.The investigation initiated by performing various single photon emission computerized tomography (SPECT)/CT scan of the national electrical manufacturers association chest phantoms having hot and cold inserts. Data acquired on GE 670 PRO SPECT/CT; 360Ø, 64 frames, 60 seconds, low energy high resolution (LEHR) 128, low energy general purpose (LEGP) with CT attenuation (120 kV and 170 mA). The images reconstructed with filtered back projection and ITERATIVE ordered-subset expectation maximization utilizing filters; Hann, Butterworth, Metz, Hamming, and Wiener. The Image contrast was calculated to assess absolute nearness of the inserts. Based on the preliminary results, then scans of 92 patients with CAD; 64 males and 28 females, age 41 to 77 years old, who had been reported earlier reprocessed with the nominated filter and were reported by 2 NM expert. The results compared to the earlier reports and to the CT-Angio and angiography.The optimization suggested 3 filters; Wiener (Wi), Metz and Butterworth (But) provide the highest contrast (99- 66.4%) and (81- 32%) for the cold and hot inserts respectively, with the (Wi) filter to be the better option. The reprocessed patients scan with the (Wi) presented an elevated diagnostic accuracy, correlated well with the CT-Angio and angiography results (P < .001 and r = 0.79 for [Wi] and P = .004 and r = 0.39 for [But]). The percentage of the false negative for moderate to severe CAD cases reported using Wi filter reduced from 27% to 7% and similarly for mild CAD cases from 7% to 1%.It appears the Wiener filter could produce results with the highest contrast for phantom imaging of various cold and hot spheres and for the patient data which is more consistent with angiography results, with much-elevated accuracy in intermediate cases (r = 0.79 for Wiener and r = 0.39 for Butterworth vs angiography). However, the optimum parameters obtained for the filters have no relation with the resolution of the imaging system, but the details of the objects could be improved.


Assuntos
Angiografia , Angiografia por Tomografia Computadorizada , Doença da Artéria Coronariana/diagnóstico por imagem , Intensificação de Imagem Radiográfica/instrumentação , Tomografia Computadorizada de Emissão de Fóton Único/instrumentação , Adulto , Idoso , Angiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagens de Fantasmas/estatística & dados numéricos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único/estatística & dados numéricos , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...