Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Exp Optom ; : 1-7, 2024 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-38402851

RESUMO

CLINICAL RELEVANCE: Reading performance is important for evaluating near vision and predicting and prescribing near-vision correction. There is a significant gap in the literature on Arabic reading performance and its associated effects. BACKGROUND: Normative data from control participants serve as the baseline for future studies involving groups with specific characteristics. This study aimed to assess baseline measures of Arabic reading performance. METHODS: In total, 428 normally sighted adults aged 19-83 years read the Balsam Alabdulkader - Leat chart to measure their reading performance. The participants were divided into five age groups. The outcome measures were the maximum reading speed in standard-length words per minute, critical print size, reading acuity, and reading accessibility index. RESULTS: The average reading performance measures were as follows: 171 ± 27 standard-length words per minute for maximum reading speed, 0.01 logarithm of the minimum angle of resolution for critical print size, -0.17 logarithm of the minimum angle of resolution for reading acuity, and 1.02 for the accessibility index. There were significant differences among the age groups, indicating a dependency on age and showing a plateau for the young adult group and a decline with age. The accessibility index had an almost perfect correlation with maximum reading speed and a weak but significant relationship with reading acuity and critical print size. CONCLUSION: Arabic exhibits an age-dependent trend in reading speed. However, owing to differences in orthography, visual demands, and reading strategies, the magnitude of the decrease and increase differs, potentially accounting for the variations between languages, especially when compared to English. This study serves as a foundation for future studies on Arabic reading performance. Future studies should examine the reading performance in patients with low vision, study the effects of common diseases on reading ability, evaluate the effectiveness of reading devices, and assess improvements in vision rehabilitation.

2.
Saudi J Ophthalmol ; 35(1): 9-14, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34667926

RESUMO

PURPOSE: To evaluate the effects of hemodialysis (HD) on visual acuity (VA), central corneal thickness (CCT), intraocular pressure (IOP), and macular thickness (MT) in chronic kidney disease (CKD) patients and also to investigate the relationship between the ocular parameters and blood biochemical parameters such as serum albumin, creatinine, sodium, and urea levels. METHODS: A prospective cohort study including a total of 24 CKD patients of both genders (above 18 years old) undergoing HD in XXX was conducted. The participants were divided into three sub-groups based on the primary cause of renal failure, group 1: Hypertensive kidney disease, group 2: Diabetic kidney disease, group 3: Other causes. All subjects underwent full ophthalmological examinations including measurement of VA using LogMAR, IOP, CCT, and CMT. Comparisons between different ocular parameters during pre- and post-HD sessions were done using the paired t-test. The relationship between changes in ophthalmologic and blood biochemical parameters was calculated using Pearson correlation coefficient. RESULTS: HD did not significantly alter any ocular parameter within and between CKD groups. Spherical equivalent changes were found to be significantly correlated with serum K (r = -0.315; P = 0.038), and IOP results were positively correlated with serum creatinine (r = 0.330; P = 0.029) and negatively correlated with hemoglobin (r = -0.349; P = 0.020). Bodyweight alterations were significantly correlated with CCT (r = -0.03; P = 0.0001). However, no correlation between ocular parameters and duration of HD was detected. CONCLUSION: Following a single HD session, ocular parameters did not alter significantly.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...