Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 16(1): e0240641, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33449935

RESUMO

γ-Aminobutyric acid (GABA) is a primary inhibitory neurotransmitter in the human brain. It has been shown that altered GABA concentration plays an important role in a variety of psychiatric and neurological disorders. The main purpose of this study was to propose a combination of PRESS and MEGA-PRESS acquisitions for absolute GABA quantification and to compare GABA estimations obtained using total choline (tCho), total creatine (tCr), and total N-acetyl aspartate (tNAA) as the internal concentration references with water referenced quantification. The second aim was to demonstrate the fitting approach of MEGA-PRESS spectra with QuasarX algorithm using a basis set of GABA, glutamate, glutamine, and NAA in vitro spectra. Thirteen volunteers were scanned with the MEGA-PRESS sequence at 3T. Interleaved water referencing was used for quantification, B0 drift correction and to update the carrier frequency of RF pulses in real time. Reference metabolite concentrations were acquired using a PRESS sequence with short TE (30 ms) and long TR (5000 ms). Absolute concentration were corrected for cerebrospinal fluid, gray and white matter water fractions and relaxation effects. Water referenced GABA estimations were significantly higher compared to the values obtained by metabolite references. We conclude that QuasarX algorithm together with the basis set of in vitro spectra improves reliability of GABA+ fitting. The proposed GABA quantification method with PRESS and MEGA-PRESS acquisitions enables the utilization of tCho, tCr, and tNAA as internal concentration references. The use of different concentration references have a good potential to improve the reliability of GABA estimation.


Assuntos
Algoritmos , Giro do Cíngulo , Espectroscopia de Ressonância Magnética , Ácido gama-Aminobutírico/metabolismo , Adulto , Feminino , Giro do Cíngulo/diagnóstico por imagem , Giro do Cíngulo/metabolismo , Humanos , Masculino , Pessoa de Meia-Idade
2.
J Magn Reson Imaging ; 2018 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-29517831

RESUMO

BACKGROUND: Lung T1 is a potential translational biomarker of lung disease. The precision and repeatability of variable flip angle (VFA) T1 mapping using modern 3D ultrashort echo time (UTE) imaging of the whole lung needs to be established before it can be used to assess response to disease and therapy. PURPOSE: To evaluate the feasibility of regional lung T1 quantification with VFA 3D-UTE and to investigate long- and short-term T1 repeatability in the lungs of naive mice. STUDY TYPE: Prospective preclinical animal study. POPULATION: Eight naive mice and phantoms. FIELD STRENGTH/SEQUENCE: 3D free-breathing radial UTE (8 µs) at 4.7T. ASSESSMENT: VFA 3D-UTE T1 calculations were validated against T1 values measured with inversion recovery (IR) in phantoms. Lung T1 and proton density (S0 ) measurements of whole lung and muscle were repeated five times over 1 month in free-breathing naive mice. Two consecutive T1 measurements were performed during one of the imaging sessions. STATISTICAL TESTS: Agreement in T1 between VFA 3D-UTE and IR in phantoms was assessed using Bland-Altman and Pearson 's correlation analysis. The T1 repeatability in mice was evaluated using coefficient of variation (CV), repeated-measures analysis of variance (ANOVA), and paired t-test. RESULTS: Good T1 agreement between the VFA 3D-UTE and IR methods was found in phantoms. T1 in lung and muscle showed a 5% and 3% CV (1255 ± 63 msec and 1432 ± 42 msec, respectively, mean ± SD) with no changes in T1 or S0 over a month. Consecutive measurements resulted in an increase of 2% in both lung T1 and S0 . DATA CONCLUSION: VFA 3D-UTE shows promise as a reliable T1 mapping method that enables full lung coverage, high signal-to-noise ratio (∼25), and spatial resolution (300 µm) in freely breathing animals. The precision of the VFA 3D-UTE method will enable better design and powering of studies. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018.

3.
PLoS One ; 11(3): e0149760, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26958856

RESUMO

PURPOSE: Interest in using T1 as a potential MRI biomarker of chronic obstructive pulmonary disease (COPD) has recently increased. Since tobacco smoking is the major risk factor for development of COPD, the aim for this study was to examine whether tobacco smoking, pack-years (PY), influenced T1 of the lung parenchyma in asymptomatic current smokers. MATERIALS AND METHODS: Lung T1 measurements from 35 subjects, 23 never smokers and 12 current smokers were retrospectively analyzed from an institutional review board approved study. All 35 subjects underwent pulmonary function test (PFT) measurements and lung T1, with similar T1 measurement protocols. A backward linear model of T1 as a function of FEV1, FVC, weight, height, age and PY was tested. RESULTS: A significant correlation between lung T1 and PY was found with a negative slope of -3.2 ms/year (95% confidence interval [CI] [-5.8, -0.6], p = 0.02), when adjusted for age and height. Lung T1 shortens with ageing among all subjects, -4.0 ms/year (95%CI [-6.3, -1.7], p = 0.001), and among the never smokers, -3.7 ms/year (95%CI [-6.0, -1.3], p = 0.003). CONCLUSIONS: A correlation between lung T1 and PY when adjusted for both age and height was found, and T1 of the lung shortens with ageing. Accordingly, PY and age can be significant confounding factors when T1 is used as a biomarker in lung MRI studies that must be taken into account to detect underlying patterns of disease.


Assuntos
Pulmão/fisiopatologia , Imageamento por Ressonância Magnética , Fumar/efeitos adversos , Adulto , Envelhecimento/fisiologia , Demografia , Feminino , Humanos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Fatores de Tempo , Adulto Jovem
4.
COPD ; 13(2): 153-9, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26488310

RESUMO

Magnetic resonance imaging (MRI) may provide attractive biomarkers for assessment of pulmonary disease in clinical trials as it is free from ionizing radiation, minimally invasive and allows regional information. The aim of this study was to characterize lung MRI T1 relaxation time as a biomarker of chronic obstructive pulmonary disease (COPD); and specifically its relationship to smoking history, computed tomography (CT), and pulmonary function test (PFT) measurements in comparison to healthy age-matched controls. Lung T1 and inter-quartile range (IQR) of T1 maps from 24 COPD subjects and 12 healthy age-matched non-smokers were retrospectively analyzed from an institutional review board approved study. The subjects underwent PFTs and two separate MR imaging sessions at 1.5 tesla to test T1 repeatability. CT scans were performed on the COPD subjects. T1 repeatability (intraclass correlation coefficient) was 0.72 for repeated scans acquired on two visits. The lung T1 was significantly shorter (p < 0.0001) and T1 IQR was significantly larger (p = 0.0002) for the COPD subjects compared to healthy controls. Lung T1 significantly (p = 0.001) correlated with lung density assessed with CT. Strong significant correlations (p < 0.0001) between lung T1 and all PFT measurements were observed. Cigarette exposure did not correlate with lung T1 in COPD subjects. In conclusion, lung MRI T1 mapping shows potential as a repeatable, radiation free, non-invasive imaging technique in the evaluation of COPD.


Assuntos
Pulmão/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/fisiopatologia , Testes de Função Respiratória , Estudos Retrospectivos , Fumar/efeitos adversos , Tomografia Computadorizada por Raios X/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...