Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Electrophoresis ; 26(7-8): 1366-75, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15761922

RESUMO

A sheath-flow capillary electrophoresis-mass spectrometry (CE-MS) system utilizing a fully integrated large-bore stainless-steel emitter electrode tapered at the end for micro-ionspray operation has been developed and evaluated. A separation capillary with an outer diameter of up to 360 microm was inserted into the electrode thus forming a void volume of less than 15 nL between the capillary end and the electrospray ionisation (ESI) tip. The sheath liquid, usually methanol-water (80:20) with 0.1% formic acid for positive ion mode or methanol for negative ion mode, was delivered at 0.5-1.0 microL/min. Unlike previously reported CE-MS interfaces, the CE-MS probe was incorporated directly onto an Applied Biosystems/MDS SCIEX orthogonal-spray Turbo "V" ion source for ease of use and automatic operation. This integration enables fast and facile coupling and replacement of the separation capillary without interrupting the ion source configuration, and the sheath liquid supply. The reusable electrospray electrode was precisely fabricated and aligned with the length of the nebulizing gas tube for improved reproducibility. Automation was achieved through software control of both CE and tandem MS (MS/MS) for unattended batch sample analysis. The system was evaluated for attomole- to low femtomole-level profiling of model peptides and protein mixtures, bisphosphates, as well as antiviral nucleosidic drugs in cellular extracts.


Assuntos
Eletroforese Capilar/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Automação , Eletroforese Capilar/instrumentação , Estudos de Avaliação como Assunto , Espectrometria de Massas por Ionização por Electrospray/instrumentação
2.
J Environ Monit ; 6(11): 897-902, 2004 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-15536503

RESUMO

We describe a method for the simultaneous determination of eight kinds of phenylbenzotriazole-type mutagens (PBTA-1, -2, -3, -4, -5, -6, -7 and -8) in river water based on liquid chromatography-tandem mass spectrometry (LC/MS/MS). The application of dopant-assisted atmospheric pressure photoionization (APPI) for the detection of the PBTAs was studied. The APPI technique provided higher PBTA signal intensities than those obtained with an electrospray ionization (ESI) source, and the APPI method was used for the determination of the PBTAs. A solid-phase extraction procedure was used for the extractions of PBTA-1 through -8 from river water. The procedure was rapid and the relative standard deviations were below 15%. The detection limits of PBTA-1 through -8 in river water using the proposed method were found to range from 0.04 to 0.5 ng L(-1) and PBTAs were successfully detected in river water at sub-ng L(-1) levels.


Assuntos
Espectrometria de Massas/métodos , Mutagênicos/análise , Triazóis/análise , Poluentes Químicos da Água/análise , Cromatografia Líquida , Monitoramento Ambiental/métodos , Japão , Rios/química , Espectrometria de Massas por Ionização por Electrospray
3.
Anal Sci ; 20(2): 375-7, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-15055970

RESUMO

We describe a method for the simultaneous determination of 12 kinds of polycyclic aromatic hydrocarbons (PAHs) in sediment based on liquid chromatography-atmospheric pressure photoionization-mass spectrometry (LC/APPI/MS). The method consists of PAH extractions by ultrasonics, clean-up by a solid-phase extraction procedure and determination by LC/APPI/MS. The limits of the determination for PAHs in sediment using the proposed method ranged from 0.06 to 0.9 mg/kg. PAHs were detected by this method in sediment samples on the mg/kg level.