Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Diagnostics (Basel) ; 14(11)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38893594

RESUMO

Ultrasound is widely used for tendon assessment due to its safety, affordability, and portability, but its subjective nature poses challenges. This study aimed to develop a new quantitative analysis tool based on artificial intelligence to identify statistical patterns of healthy and pathological tendons. Furthermore, we aimed to validate this new tool by comparing it to experts' subjective assessments. A pilot database including healthy controls and patients with patellar tendinopathy was constructed, involving 14 participants with asymptomatic (n = 7) and symptomatic (n = 7) patellar tendons. Ultrasonographic images were assessed twice, utilizing both the new quantitative tool and the subjective scoring method applied by an expert across five regions of interest. The database contained 61 variables per image. The robustness of the clinical and quantitative assessments was tested via reliability analyses. Lastly, the prediction accuracy of the quantitative features was tested via cross-validated generalized linear mixed-effects logistic regressions. These analyses showed high reliability for quantitative variables related to "Bone" and "Quality", with ICCs above 0.75. The ICCs for "Edges" and "Thickness" varied but mostly exceeded 0.75. The results of this study show that certain quantitative variables are capable of predicting an expert's subjective assessment with generally high cross-validated AUC scores. A new quantitative tool for the ultrasonographic assessment of the tendon was designed. This system is shown to be a reliable and valid method for evaluating the patellar tendon structure.

2.
Diagnostics (Basel) ; 14(12)2024 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-38928673

RESUMO

(1) Background: The diagnosis of lumbosacral radiculopathy involves anamnesis, an assessment of sensitivity and strength, diagnostic imaging-usually magnetic resonance imaging (MRI)-and electrodiagnostic testing (EDX), typically electromyography (EMG), and electroneurography (ENG). MRI evaluates the structures supporting the spinal cord, while EDX evaluates root functionality. The present study aimed to analyze the concordance of MRI and EDX findings in patients with clinically suspected radiculopathy. Additionally, we investigated the comparison between these two reference tests and various clinical variables and questionnaires. (2) Methods: We designed a prospective epidemiological study of consecutive cases with an observational, descriptive, cross-sectional, and double-blind nature following the STROBE guidelines, encompassing 142 patients with clinical suspicion of lumbosacral radiculopathy. (3) Results: Of the sample, 58.5% tested positive for radiculopathy using EDX as the reference test, while 45.8% tested positive using MRI. The comparison between MRI and EDX in the diagnosis of radiculopathy in patients with clinical suspicion was not significant; the overall agreement was 40.8%. Only the years with symptoms were comparatively significant between the positive and negative radiculopathy groups as determined by EDX. (4) Conclusion: The comparison between lumbar radiculopathy diagnoses in patients with clinically suspected pathology using MRI and EDX as diagnostic modalities did not yield statistically significant findings. MRI and EDX are complementary tests assessing different aspects in patients with suspected radiculopathy; degeneration of the structures supporting the spinal cord does not necessarily imply root dysfunction.

3.
Healthcare (Basel) ; 12(10)2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38786411

RESUMO

BACKGROUND: Evidence suggests the plantar fascia and its interphase with the flexor digitorum brevis muscle can play a relevant role in plantar heel pain. Needling interventions could offer an appropriate treatment strategy to addressing this interface. OBJECTIVE: We compared the accuracy and safety of ultrasound-guided versus palpation-guided procedures for the proper targeting of the interface between the plantar fascia and the flexor digitorum brevis with a solid needle. METHODS: A crossover cadaveric study was conducted. Five experienced therapists performed a series of 20 needle insertions each (n = 100 in total, 10 landmark-guided and 10 ultrasound-guided) on 10 anatomical samples. The therapists were instructed to accurately place the needle on the interface between the plantar fascia and the flexor digitorum brevis muscle. The distance of the tip of the needle to the identified target (accuracy), the surrounding sensitive structures targeted (safety), the time needed for the procedure, the number of needle passes, and the needle length outside the skin were assessed. RESULTS: The ultrasound-guided technique was associated with a significantly higher accuracy (p < 0.001) but without differences in safety (p = 0.249) as compared to the palpation-guided procedure. CONCLUSION: Our results suggest that ultrasound-guided insertion exhibits greater accuracy but not greater safety than palpation-guided insertion when targeting the interface between the plantar fascia and the flexor digitorum brevis.

4.
Diagnostics (Basel) ; 14(3)2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38337859

RESUMO

Peripheral nerves are subjected to mechanical tension during limb movements and body postures. Nerve response to tensile stress can be assessed in vivo with shear-wave elastography (SWE). Greater tensile loads can lead to greater stiffness, which can be quantified using SWE. Therefore, this study aimed to conduct a systematic review and meta-analysis to perform an overview of the effect of joint movements on nerve mechanical properties in healthy nerves. The initial search (July 2023) yielded 501 records from six databases (PubMed, Embase, Scopus, Web of Science, Cochrane, and Science Direct). A total of 16 studies were included and assessed with a modified version of the Downs and Black checklist. Our results suggest an overall tendency for stiffness increase according to a pattern of neural tensioning. The main findings from the meta-analysis showed a significant increase in nerve stiffness for the median nerve with wrist extension (SMD [95%CI]: 3.16 [1.20, 5.12]), the ulnar nerve with elbow flexion (SMD [95%CI]: 2.91 [1.88, 3.95]), the sciatic nerve with ankle dorsiflexion (SMD [95%CI]: 1.13 [0.79, 1.47]), and the tibial nerve with both hip flexion (SMD [95%CI]: 2.14 [1.76, 2.51]) and ankle dorsiflexion (SMD [95%CI]: 1.52 [1.02, 2.02]). The effect of joint movement on nerve stiffness also depends on the nerve segment, the amount of movement of the joint mobilized, and the position of other joints comprised in the entirety of the nerve length. However, due to the limited number of studies, many aspects of nerve behavior together with the effect of using different ultrasound equipment or transducers for nerve stiffness evaluation still need to be fully investigated.

5.
Life (Basel) ; 13(10)2023 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-37895441

RESUMO

For decades, needling interventions have been performed based on manual palpation and anatomic knowledge. The increasing use of real-time ultrasonography in clinical practice has improved the accuracy and safety of needling techniques. Although currently ultrasound-guided procedures are routinely used for patellar tendon pathology, e.g., during percutaneous electrolysis, the accuracy of these procedures is still unknown. This study used a cadaveric model to compare and evaluate both the accuracy and safety of ultrasound-guided and palpation-guided needling techniques for the patellar tendon. A total of five physical therapists performed a series of 20 needle insertion task each (n = 100), 10 insertions based on manual palpation (n = 50) and 10 insertions guided with ultrasound (n = 50) to place a needle along the interface between the patellar tendon and Hoffa's fat pad. All procedures were performed on cryopreserved knee specimens. Distance to the targeted tissue, time of the procedure, accurate rate of insertions, number of passes, and unintentional punctured structures between both applications (with and without ultrasound guiding) were compared. The results revealed higher accuracy (100% vs. 80%), a lower distance from needle to the targeted tissue (0.25 ± 0.65 vs. 2.5 ± 1.9 mm), longer surface of contact with the needle (15.5 ± 6.65 vs. 4.7 ± 7.5 mm), and a lower frequency of patellar tendon puncture (16% vs. 52%, p < 0.001) with the ultrasound-guided procedure as opposed to palpation-guided one. Nevertheless, the ultrasound-guided procedure took longer (54.8 ± 26.8 vs. 23.75 ± 15.4 s) and required more passes (2.55 ± 1.9 vs. 1.5 ± 0.95) to be conducted than the palpation-guided procedure (all, p < 0.001). According to these findings, the accuracy of invasive procedures applied on the patellar tendon is higher when conducted with ultrasound guidance than when conducted just on manual palpation or anatomical landmark. These results suggest that ultrasound could improve the clinical application of invasive procedures at the fat-patellar tendon interface. Due to the anatomical features of the targeted tissue, some procedures require this precision, so the use of ultrasound is recommended.

6.
Healthcare (Basel) ; 11(11)2023 May 30.
Artigo em Inglês | MEDLINE | ID: mdl-37297743

RESUMO

Percutaneous electrical stimulation has been performed for years with only the assistance of anatomical landmarks. The development of real-time ultrasonography guidance has improved the precision and safety of these percutaneous interventions. Despite ultrasound-guided and palpation-guided procedures being performed routinely for targeting nerve tissues in the upper extremity, the precision and safety of these techniques are unknown. The aim of this cadaveric study was to determine and compare the precision and safety of ultrasound-guided versus palpation-guided needling procedure with and without the handpiece of the ulnar nerve on a cadaveric model. Five physical therapists performed a series of 20 needle insertion tasks each (n = 100), 10 palpation-guided (n = 50) and 10 ultrasound-guided (n = 50) on cryopreserved specimens. The purpose of the procedure was to place the needle in proximity to the ulnar nerve at the cubital tunnel. The distance to target, time performance, accurate rate, number of passes, and unintentional puncture of surrounding structures were compared. The ultrasound-guided procedure was associated with higher accuracy (66% vs. 96%), lower distance from needle to the target (0.48 ± 1.37 vs. 2.01 ± 2.41 mm), and a lower frequency of perineurium puncture (0% vs. 20%) when compared with the palpation-guided procedure. However, the ultrasound-guided procedure required more time (38.33 ± 23.19 vs. 24.57 ± 17.84 s) than the palpation-guided procedure (all, p < 0.001). Our results support the assumption that ultrasound guidance improves the accuracy of needling procedures on the ulnar nerve at the cubital tunnel when compared with palpation guidance.

7.
Am J Phys Med Rehabil ; 102(12): 1091-1096, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37205741

RESUMO

OBJECTIVES: The aims of the study are to analyze and describe the accuracy of an ultrasound-guided approach to target the L5 root in cadaveric specimens and evaluate whether gender differences exist. DESIGN: A cross-anatomical study on 40 cadaver L5 nerve roots was performed. A needle was introduced until contacting the L5 nerve root using ultrasound guidance. After that, specimens were frozen and studied by a cross-anatomical view to see the needle's path. The angulation, length, distance from the vertebral spine, the relevant ultrasound anatomical references, and the accuracy of the procedure were evaluated. RESULTS: The needle tip reached the L5 root at a 72.5% rate. The mean angulation degrees of the needle relative to the skin surface were 75.53 ± 10.17 degrees, the length of the needle inserted was 5.83 ± 0.82 cm, and the distance from the vertebral spine to the point of entry of the needle was 5.39 ± 1.44 cm. CONCLUSIONS: An ultrasound-guided technique can potentially be an accurate technique to perform invasive procedures on the L5 root. There were statistically significant differences between males and females in the length of the needle introduced. If the L5 root is not clearly visualized, ultrasound will not be the technique of choice.


Assuntos
Vértebras Lombares , Raízes Nervosas Espinhais , Masculino , Feminino , Humanos , Raízes Nervosas Espinhais/diagnóstico por imagem , Ultrassonografia , Vértebras Lombares/diagnóstico por imagem , Ultrassonografia de Intervenção/métodos , Cadáver
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...