Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Orthop Rev (Pavia) ; 14(4): 37889, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36213618

RESUMO

Femoral shaft nonunions are disabling complications of fractures, with relevant socioeconomic and psychological impact. The incidence of femoral shaft nonunions is not negligible, ranging between 1% and 10% after intramedullary nailing, but can exceed 20% in case of subtrochanteric fractures. Treatment options are influenced by pathomechanical, anatomical, and clinical factors. Hypertrophic nonunions are usually treated by enhancing stability of fixation, while atrophic nonunions require additional biological stimulation to achieve bone union. The Reamer-Irrigator-Aspirator (RIA) System® was developed to reduce intramedullary pressure and heat generation during intramedullary reaming, thus preventing thermal necrosis and decreasing the risk of fat embolism. The RIA System allows to provide large volumes of high-quality morselized autologous bone, that has shown high osteogenetic and osteoinductive properties. Therefore, its use has been expanded as a valuable source of autologous bone graft for the treatment of large bone defects of different nature. In this article, we present two cases of complex femoral nonunions treated with the use of the RIA System. A review of the published literature on the treatment of femoral nonunions with RIA was also performed. Core tip: In case of atrophic nonunions, the RIA System can be used to obtain biologically active tissue to enhance bone healing. Despite the absence of high-quality studies focused on femoral nonunions, the efficacy of RIA is well-known and orthopaedic surgeons should be aware of this powerful tool.

2.
Geriatrics (Basel) ; 6(3)2021 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-34287327

RESUMO

The purpose of this retrospective study is to compare the short-term clinical and radiological results between standard and dual mobility THA for femoral neck fractures (FNF) in older patients. The hypothesis is that the dual mobility cup (DMC) has the same outcomes but a lower dislocation rate than the standard THA. The study population included 56 patients (mean age 77.7 years, range 71-85) that underwent THA for displaced FNF. Patients were divided in two comparable groups for baseline characteristics (age, sex and comorbidities): 28 patients underwent THA with a standard cup (SC) and 28 THA with DMCs. The clinical records and radiograms were reviewed to search relevant data in their postoperative history. Two postoperative dislocations occurred in the SC group and none in the DMC group. At an average follow up of 23 months (12-40), 48 patients were available for the final evaluation. The WOMAC score for all patients averaged 6.26 (0-46) and was slightly better in the DMC group (4.94 vs. 7.58; p-value = 0.41); scores were significantly better in presence of neurological comorbidities (p-value = 0.04), in the absence of diabetes (p-value = 0.04) and in the case of psychiatric disorders (p-value = 0.02). Radiographic evaluation at one year showed signs of osteointegration in 42/48 (87.5%) acetabular components (20 DMCs, 22 SC). According to our experience, DMCs proved to be a valid option for the treatment of displaced FNF in older patients, since it allowed them to achieve short-term outcomes comparable to conventional THA, while decreasing the incidence of postoperative dislocations.

3.
Orthop Rev (Pavia) ; 12(Suppl 1): 8659, 2020 Jun 29.
Artigo em Inglês | MEDLINE | ID: mdl-32913595

RESUMO

Shoulder replacement is indicated for the surgical treatment of proximal humeral fractures in elderly patients, when severe comminution and osteoporosis jeopardize the chances of success of any fixation technique. Two different implants are available for this purpose: anatomical hemiarthroplasty (HA) and reverse total shoulder arthroplasty (RTSA). HA for fractures was popularized by Charles Neer in the '50s and for several decades remained the only reliable implant for these injuries. However, many authors reported inconsistent results with HA as a consequence of the high rate of tuberosity and rotator cuff failure. In 1987, Paul Grammont designed the first successful RTSA, which was the end result of a long thought process on functional surgery of the shoulder. This implant was initially used to treat cuff tear arthropathy and shoulder pseudoparalysis, but indications have gradually expanded with time. Since RTSA does not rely on a functional cuff for shoulder elevation, it was felt that results in fractures could be improved by this prosthesis. In this study, the salient features of these implants are described to understand the rationale behind both approaches and highlight their pros and cons. Several clinical studies comparing HA vs RTSA for proximal humeral fractures have been published during the last two decades. A literature review is carried out to analyze and compare outcomes of both implants, analyzing clinical results, radiographic findings and complications. The final goal is to provide an overview of the different factors to consider for making a choice between these two prostheses.

4.
Hip Int ; 30(6): 810-817, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31450987

RESUMO

INTRODUCTION: Femoral neck fractures are a major problem in orthopaedic practice, having a huge impact on society, and involving a large number of elderly patients for whom early recovery is paramount. Thus, the aim of this study was to compare 2 surgical approaches, direct anterior (DA group) versus posterolateral (PL group), used for bipolar hip hemiarthroplasty (BHA) with femoral neck fractures in order to assess pain recovery after surgery. Our hypothesis was that early pain recovery would be faster in the DA group. METHODS: 100 patients were randomised to surgery using either a DA group or PL group approach, and were then followed up for 6 months. Surgical time, intra- and postoperative complications were recorded for each patient. The main outcome, pain, was recorded using an NRS scale at 3 days, 1, 3 and 6 months after surgery. At the same time, patient status was evaluated using Activities of Daily Living and Cumulated Ambulation Score scales. RESULTS: Surgical time was longer in the DA group (p < 0.0001). Pain perception at 3 days and at 1 month after surgery was significantly lower in DA group patients (p < 0.0001). The results of the other scales were comparable in the 2 groups (at 3 days, 1 and 3 months after surgery). DISCUSSION: The DA approach offers a significant advantage in terms of pain perception up to 1 month after the operation. Early recovery in terms of pain perception is an important finding. Future studies should explore whether this early pain reduction could translate into a faster rehabilitation programme for an earlier recovery of full function.Clinical trial registration: Protocol 423/CE; Study n. CE 41/15.


Assuntos
Atividades Cotidianas , Fraturas do Colo Femoral/cirurgia , Hemiartroplastia/métodos , Articulação do Quadril/cirurgia , Amplitude de Movimento Articular/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Fraturas do Colo Femoral/fisiopatologia , Articulação do Quadril/fisiopatologia , Humanos , Masculino , Duração da Cirurgia , Estudos Prospectivos , Resultado do Tratamento
5.
Joints ; 7(4): 141-147, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34235377

RESUMO

Purpose This article compares short-term outcomes of two series of patients, who underwent reverse total shoulder arthroplasty (RTSA) with two different implants, both based on Grammont's principles: the Delta III (D-3) and the Delta Xtend (D-XT) prostheses. Methods The D-3 group included a consecutive series of 26 patients (mean age 75 years), that were treated between 2000 and 2006; the D-XT group included a consecutive series of 31 patients (mean age 72.5 years), for a total of 33 implants performed between 2011 and 2015. In both groups the most common diagnoses were cuff tear arthropathy (18 and 22 shoulders, respectively) and malunion of proximal humerus fractures (3 and 5). All procedures were performed by the same surgeon. Constant-Murley score (CMS) was used to assess clinical and functional outcomes. Radiographic evaluation included the true anteroposterior and axillary views. Results Twenty-three patients of the D-3 group and 22 patients (24 shoulders) of the D-XT group were evaluated at a mean follow-up of 42 months (range 26-84) and 44 months (range 26-66), respectively. Four complications occurred in the D-3 group (1 partial deltoid detachment, 1 dislocation, and 2 glenoid component loosening), while one early postoperative infection occurred in the D-XT group. Increases in elevation and CMS between preoperative and postoperative period were observed in both groups; only the D-XT group showed a slight improvement in rotations. The incidence of scapular notching was significantly different between the two groups: 100% for D-3 and 22.2% for D-XT in patients with a minimum follow-up of 5 years. Conclusion Prosthetic design evolution and greater acquaintance with this surgery have undoubtedly led to an improvement in short-term outcomes with second generation implants of RTSA. Future studies will have to ascertain whether newer implants, relying on biomechanical solutions alternative to Grammont's original concept, might provide additional advantages and minimize drawbacks.

6.
Adv Orthop ; 2018: 5904028, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29971167

RESUMO

BACKGROUND: The aim of this study was to evaluate the clinical and radiographic results after minimally invasive plate osteosynthesis (MIPO) for proximal humerus fractures. Potential advantages of this approach include the easier exposure of the greater tuberosity and the limited surgical dissection around the fracture site. MATERIALS AND METHODS: From October 2011 to March 2016, thirty-nine patients (32 women, 7 men) with a mean age of 64.9 years (range: 48-80) were surgically treated with the MIPO technique for proximal humeral fractures. According to Neer classification, there were 12 two-part, 24 three-part, and 2 four-part fractures and 1 two-part fracture-dislocation; the AO/OTA system was also used to categorize the fractures. The Constant-Murley (CMS) and the Oxford Shoulder (OSS) Scores were used to evaluate shoulder function. RESULTS: Thirty-four patients were available for clinical and radiographic evaluation at a mean follow-up of 31.8 months (range: 12-54 months). All fractures healed and no postoperative complications occurred. Full recovery of pretrauma activities was reported by 27 patients, while 7 patients presented mild functional limitations. The mean absolute CMS was 75.2 (range: 55-95), the mean normalized CMS was 90.5 (range: 69-107), and the mean OSS was 43.7 (range: 31-48). The only statistically significant correlation was found between the female gender and lower absolute CMS and OSS. Radiographic evaluation revealed varus malunion in 4 cases and valgus malunion in 1 case, while incomplete greater tuberosity reduction was detected in 4 cases. All malunions were related to inadequate reduction at time of surgery and not to secondary displacement. CONCLUSIONS: MIPO for proximal humeral fractures is an effective and safe surgical procedure. The limited tissue dissection allows minimizing the incidence of nonunion, avascular necrosis, and infection. The technique is not easy, requires experience to achieve mastery, and should be reserved for selected fracture patterns. In our experience, the main advantage of this approach consists in the direct access to the greater tuberosity, thus facilitating its anatomic reduction and fixation.

7.
J Orthop Surg (Hong Kong) ; 17(2): 151-6, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19721141

RESUMO

PURPOSE: To report the clinical and radiographic results and complications of the Delta III reverse prosthesis. METHODS: 24 women and 2 men aged 62 to 84 (mean, 75) years underwent total shoulder replacement using the Delta III reverse prosthesis. Patient diagnoses were massive rotator cuff tear (n=20), disabling sequelae of proximal humeral fractures (n=3), and failure of an unconstrained arthroplasty (n=3). Clinical and functional results were assessed using the Constant scale. Active range of motion (ROM) was measured. Scapular notching and radiolucent lines around the humeral component were evaluated using radiographs. Patient satisfaction of the treatment was evaluated by a direct interview. RESULTS: 23 patients were followed up for 26 to 84 (mean, 42) months. Two patients had loosening of the glenoid component (at 6 months and 5 years) and underwent revision surgery. There were no instances of infection, instability, or acromial fracture. Only active elevation improved significantly after surgery, as did both the absolute and adjusted Constant scores. 12 patients were completely pain-free, 9 complained of slight pain, and one of moderate pain. The severity of scapular notching progressed with time. 15 patients were satisfied with the treatment, 6 were partially satisfied, and 2 were not satisfied. CONCLUSION: The Delta III prosthesis restores shoulder function but has biomechanical limits. Its use should be limited to elderly patients with severe impairment of the glenohumeral joint. Scapular notching is a main concern for the long-term survival of the implant.


Assuntos
Artroplastia de Substituição/métodos , Prótese Articular , Articulação do Ombro/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Entrevistas como Assunto , Instabilidade Articular/diagnóstico por imagem , Instabilidade Articular/cirurgia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Complicações Pós-Operatórias , Falha de Prótese , Radiografia , Amplitude de Movimento Articular , Reoperação , Manguito Rotador/diagnóstico por imagem , Manguito Rotador/cirurgia , Lesões do Manguito Rotador , Fraturas do Ombro/diagnóstico por imagem , Fraturas do Ombro/cirurgia , Articulação do Ombro/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...