Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(14)2022 Jul 16.
Artigo em Inglês | MEDLINE | ID: mdl-35891008

RESUMO

A 3D-printed phased array consisting of four H-Sectorial horn antennas of 200 g weight with an ultra-wideband rectangular-waveguide-to-microstrip-line transition operating over the whole LMDS and K bands (24.25-29.5 GHz) is presented. The transition is based on exciting three overlapped transversal patches that radiate into the waveguide. The transition provides very low insertion losses, ranging from 0.30 dB to 0.67 dB over the whole band of operation (23.5-30.4 GHz). The measured fractional bandwidth of the phased array including the transition was 20.8% (24.75-30.3 GHz). The antenna was measured for six different scanning angles corresponding to six different progressive phases α, ranging from 0° to 140° at the central frequency band of operation of 26.5 GHz. The maximum gain was found in the broadside direction α = 0°, with 15.2 dB and efficiency η = 78.5%, while the minimum was found for α = 140°, with 13.7 dB and η = 91.2%.

2.
Sensors (Basel) ; 16(3)2016 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-26999132

RESUMO

A critical parameter to assess the environmental status of water bodies is the transparency of the water, as it is strongly affected by different water quality related components (such as the presence of phytoplankton, organic matter and sediment concentrations). One parameter to assess the water transparency is the diffuse attenuation coefficient. However, the number of subsurface irradiance measurements obtained with conventional instrumentation is relatively low, due to instrument costs and the logistic requirements to provide regular and autonomous observations. In recent years, the citizen science concept has increased the number of environmental observations, both in time and space. The recent technological advances in embedded systems and sensors also enable volunteers (citizens) to create their own devices (known as Do-It-Yourself or DIY technologies). In this paper, a DIY instrument to measure irradiance at different depths and automatically calculate the diffuse attenuation Kd coefficient is presented. The instrument, named KdUINO, is based on an encapsulated low-cost photonic sensor and Arduino (an open-hardware platform for the data acquisition). The whole instrument has been successfully operated and the data validated comparing the KdUINO measurements with the commercial instruments. Workshops have been organized with high school students to validate its feasibility.

3.
Sensors (Basel) ; 15(1): 611-34, 2014 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-25558997

RESUMO

The need for covering large areas in oceanographic measurement campaigns and the general interest in reducing the observational costs open the necessity to develop new strategies towards this objective, fundamental to deal with current and future research projects. In this respect, the development of low-cost instruments becomes a key factor, but optimal signal-processing techniques must be used to balance their measurements with those obtained from accurate but expensive instruments. In this paper, a complete signal-processing chain to process the fluorescence spectra of marine organisms for taxonomic discrimination is proposed. It has been designed to deal with noisy, narrow-band and low-resolution data obtained from low-cost sensors or instruments and to optimize its computational cost, and it consists of four separated blocks that denoise, normalize, transform and classify the samples. For each block, several techniques are tested and compared to find the best combination that optimizes the classification of the samples. The signal processing has been focused on the Chlorophyll-a fluorescence peak, since it presents the highest emission levels and it can be measured with sensors presenting poor sensitivity and signal-to-noise ratios. The whole methodology has been successfully validated by means of the fluorescence spectra emitted by five different cultures.


Assuntos
Algoritmos , Custos e Análise de Custo , Espectrometria de Fluorescência/economia , Espectrometria de Fluorescência/instrumentação , Análise de Componente Principal , Padrões de Referência , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Análise de Ondaletas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...