Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Support Care Cancer ; 28(3): 1241-1248, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31227988

RESUMO

PURPOSE: Radiotherapy treatment may generate anxiety, especially on the first day of treatment. This study aimed to identify potential predictors of radiotherapy-related anxiety in women  with breast cancer before treatment initiation, in terms of treatment concerns and trait anxiety. METHODS: This transversal study included 94 patients from one Radiation Oncology Department, who had been diagnosed with primary breast cancer and who had been prescribed external radiotherapy for the first time. Patients completed a Treatment Concerns Questionnaire and the State-Trait Anxiety Inventory (STAI) before the  first treatment session. RESULTS: Women identified radiation involved in the procedure and treatment efficacy as major concerns surrounding radiotherapy. No significant differences were found between patients with higher and lower state anxiety scores, or by age, level of education, cancer treatment protocol used, prior information given about treatment, or report of doubts before treatment initiation. In the final model, the combination of trait anxiety (49.1% of the total variance) with two treatment-related concerns, regarding radiation and the duration of treatment (plus 10.8% of the total variance), significantly predicted treatment-related anxiety experienced on the first day of treatment. CONCLUSION: Our findings highlight the need to identify women with moderate or higher levels of trait anxiety before radiotherapy initiation and to provide them with a more approach to personalized care, adjusted to their specific concerns and susceptibility to anxious reactions. Effective education sessions involving the discussion of specific treatment concerns, and anxiety coping strategies training should be developed and applied in initial interactions with breast cancer patients.


Assuntos
Ansiedade/diagnóstico , Neoplasias da Mama/radioterapia , Adaptação Psicológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Transtornos de Ansiedade , Feminino , Humanos , Pessoa de Meia-Idade , Inquéritos e Questionários
2.
Microbiol Resour Announc ; 8(39)2019 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-31558636

RESUMO

Mariprofundus sp. strain EBB-1 was isolated from a pyrrhotite biofilm incubated in seawater from East Boothbay (ME, USA). Strain EBB-1 is an autotrophic member of the class Zetaproteobacteria with the ability to form iron oxide biominerals. Here, we present the 2.88-Mb genome sequence of EBB-1, which contains 2,656 putative protein-coding sequences.

3.
Fisioter. pesqui ; 21(4): 346-352, Oct-Dec/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-735909

RESUMO

Diottix(r) was calibrated at 25 Hz to achieve the frequency indicated in literature as being effective to mobilize the airways secretions. However, the amplitude and frequency of the waves generated by the equipment in different regions of the chest still need to be investigated. The objective of this study was to analyze the frequency and amplitude of waves generated by Diottix(r) in chests of healthy subjects. Diottix(r) was used in the anterior and posterior regions of the chest. The mechanical waves were captured using stethoscopes connected to electret microphones, which were connected to a digital oscilloscope. Frequency and amplitude data were recorded by the stethoscope, positioned in six points in the anterior region and six in the posterior region of the chest, following the positions commonly used in pulmonary auscultation. Signals were recorded and transferred to a computer with software for their analysis. The frequency of waves did not present a significant change (from 24.9 to 26.4 Hz). The wave amplitude in the anterior versus the posterior region in each area of the lung, the upper, middle and lower, had differences. Diottix(r) produces frequencies in the chest according to the calibrated; thus, it can be a complementary resource to bronchial hygiene maneuvers. The amplitudes of waves seem to be affected by other structures like bone parts and heart.


Diottix(r) fue calibrado en 25 Hz para alcanzar la frecuencia indicada en la literatura como eficaz para movilizar secreciones de las vías aéreas. La amplitud y frecuencia de ondas generadas por el equipamiento en las diferentes regiones del tórax aun necesitan de más investigaciones. El objetivo de eso estudio fue analizar la frecuencia y amplitud de ondas generadas por el Diottix(r) en el tórax de sujetos saludables. La aplicación del Diottix(r) fue realizada en las regiones anterior y posterior del tórax. Las ondas mecánicas fueron captadas utilizándose estetoscopios ligados a micrófonos de electret, los cuales estaban ligados a uno osciloscopio digital. Los datos de frecuencia y amplitud fueron captados por lo estetoscopio posicionado en seis puntos en la región anterior y seis en la posterior del tórax, siguiendo las posiciones comúnmente utilizadas en la ausculta pulmonar. Los sígnales fueron registrados y transferidos para una computadora a través de un programa para su análisis de datos. La frecuencia de ondas no presentó variación significativa (del 24,9 al 26,4 Hz). La amplitud de onda en la región anterior versus posterior en cada segmento del pulmón, tercio superior, medio e inferior, presentó diferencia. Lo Diottix(r) produce frecuencias en el tórax según el calibrado. Por lo tanto, puede ser uno recurso complementar a las manobras de higiene de los bronquios. Las amplitudes de ondas parecen ser afectadas por otras estructuras, las cuales incluyen partes óseas y el corazón.


O Diottix(r) foi calibrado a 25 Hz para atingir a frequência indicada na literatura como eficaz a fim de mobilizar secreções de vias aéreas. A amplitude e a frequência das ondas geradas pelo equipamento nas diferentes regiões do tórax ainda precisam ser investigadas. O objetivo de estudo foi analisar a frequência e a amplitude das ondas geradas pelo Diottix(r) no tórax de indivíduos saudáveis. A aplicação do Diottix(r) foi realizada nas regiões anterior e posterior do tórax. As ondas mecânicas foram captadas utilizando estetoscópios conectados a microfones de eletreto, os quais estavam ligados a um osciloscópio digital. Os dados de frequência e amplitude foram captados pelo estetoscópio, posicionado em seis pontos na região anterior e seis na posterior do tórax, seguindo as posições comumente utilizadas na ausculta pulmonar. Os sinais foram registrados e transferidos para um computador por meio de um software para análise deles. A frequência das ondas não apresentou variação significativa (24,9 a 26,4 Hz). A amplitude de onda na região anterior versus posterior em cada segmento do pulmão, terço superior, médio e inferior, apresentou diferença. O Diottix(r) produz frequências no tórax de acordo com o calibrado; desta forma, pode ser um recurso complementar às manobras de higiene brônquica. As amplitudes de ondas parecem ser afetadas por outras estruturas, que incluem as partes ósseas e o coração.


Assuntos
Humanos , Masculino , Adulto Jovem , Oscilação da Parede Torácica , Manipulações Musculoesqueléticas/instrumentação , Terapia Respiratória , Respiração com Pressão Positiva/instrumentação , Vibração , Radiação Eletromagnética , Modalidades de Fisioterapia/instrumentação , Tórax
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...