Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 25(11): 1405-12, 2000 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-10828923

RESUMO

STUDY DESIGN: Randomized control post-test only. OBJECTIVES: To investigate the reliability and validity of the EPIC Lift Capacity test's indicators of sincere effort. SUMMARY OF BACKGROUND DATA: The EPIC Lift Capacity test (ELC) (Employment Potential Improvement Corp., Santa Ana, CA) is a functional evaluation tool used to identify physical limitations involved in lifting and manual materials handling. Identification of insincere effort is an integral component of such functional testing because of the potential secondary gain issues surrounding the various populations typically involved in this form of testing. The purpose of this study was to determine the sensitivity and specificity of the "indicators of sincere effort" of the EPIC Lift Capacity test when used on a previously injured population typical of subjects for which the test is designed. METHODS: Subjects consisted of 41 volunteers (age 22 to 58 years) with a previously diagnosed musculoskeletal pathology of the spine or extremities. Volunteers were randomized into either the control group, instructed to give a sincere maximum effort, or the experimental group, instructed to give an insincere effort at 50% of their perceived maximum effort. All tests were administered by certified clinical evaluators according to the standardized EPIC Lift Capacity test protocol.- RESULTS: Overall accuracy in identifying participants' level of effort was 86.84%. The indicators of valid effort exhibited both high positive (94.44%) and negative (80.00%) predictive values. The indicators of valid effort accounted for 94.9% of the total variance in the determination of the subjects' overall effort level. Interrater reliability for agreement of subjects' overall effort was good (interclass correlation coefficient = 0.82). CONCLUSIONS: Through use of standardized indicators of sincere effort, certified EPIC Lift Capacity test evaluators were able to predict sincerity of effort with a high degree of reliability and validity. The rater's systematicobservational evaluation of effort was shown to be the single best indicator of sincere effort.


Assuntos
Lesões nas Costas/diagnóstico , Remoção , Exame Físico/normas , Desempenho Psicomotor , Adulto , Lesões nas Costas/psicologia , Fenômenos Biomecânicos , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Participação do Paciente , Exame Físico/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Circulation ; 99(21): 2771-8, 1999 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-10351971

RESUMO

BACKGROUND: The crista terminalis (CT) has been identified as the posterior boundary of typical atrial flutter (AFL) in the lateral wall (LW) of the right atrium (RA). To study conduction properties across the CT, rapid pacing was performed at both sides of the CT after bidirectional conduction block was achieved in the cavotricuspid isthmus by radiofrequency catheter ablation. METHODS AND RESULTS: In 22 patients (aged 61+/-7 years) with AFL (cycle length, 234+/-23 ms), CT was identified during AFL by double electrograms recorded between the LW and posterior wall (PW). After the ablation procedure, decremental pacing trains were delivered from 600 ms to 2-to-1 local capture at the LW and PW or coronary sinus ostium (CSO). At least 5 bipolar electrograms were recorded along the CT from the high to the low atrium next to the inferior vena cava. No double electrograms were recorded during sinus rhythm in that area. Complete transversal conduction block all along the CT (detected by the appearance of double electrograms at all recording sites and craniocaudal activation sequence on the side opposite to the pacing site) was observed in all patients during pacing from the PW or CSO (cycle length, 334+/-136 ms), but it was fixed in only 4 patients. During pacing from the LW, complete block appeared at a shorter pacing cycle length (281+/-125 ms; P<0.01) and was fixed in 2 patients. In 3 patients, complete block was not achieved. CONCLUSIONS: These data suggest the presence of rate-dependent transversal conduction block at the crista terminalis in patients with typical AFL. Block is usually observed at longer pacing cycle lengths with PW pacing than with LW pacing. This difference may be a critical determinant of the counterclockwise rotation of typical AFL.


Assuntos
Flutter Atrial/fisiopatologia , Função do Átrio Direito/fisiologia , Sistema de Condução Cardíaco/fisiopatologia , Valva Tricúspide/fisiopatologia , Veias Cavas/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial , Eletrocardiografia , Estudos de Avaliação como Assunto , Humanos , Pessoa de Meia-Idade
3.
Pacing Clin Electrophysiol ; 16(3 Pt 2): 535-9, 1993 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7681953

RESUMO

The initial experience from electrophysiological studies showed that pacing induced termination of ventricular tachycardias is usually possible but requires a critical pacing sequence. Studies on the resetting phenomenon showed, in most instances of failure of termination, that the "limiting factor" to produce ventricular tachycardia termination is usually failure to produce block within the circuit rather than failure to access or interact with the ventricular tachycardia origin. The resetting response is related to tachycardia termination in a number of ways. Of note is that a steeply increasing resetting pattern usually predicts tachycardia termination. Between 50% and 90% of induced ventricular tachycardias will be terminated by trains of rapid ventricular pacing. The analysis of the pacing rate necessary for termination shows that it varies widely. Paced cycle lengths of < 80% of tachycardia cycle length are necessary in at least 20% of tachycardias. In contrast, the incidence of acceleration is closely related to the paced cycle length: it is negligible with paced cycle lengths over 80% of tachycardia cycle length and increases to 36% with paced cycle lengths below 76% of tachycardia cycle length. Present information about efficacy of antitachycardia pacing in spontaneous tachycardias suggests that it is extremely effective, with over 90% success. However, it is likely that these data correspond to a selected group of tachycardias.


Assuntos
Estimulação Cardíaca Artificial , Taquicardia Ventricular/terapia , Estimulação Cardíaca Artificial/métodos , Desfibriladores Implantáveis , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...