Front Oncol ; 12: 833364, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35515119

RESUMO

Proton beam therapy (PBT) is often more attractive for its high gradient dose distributions than other treatment modalities with external photon beams. However, in thoracic lesions treated particularly with pencil beam scanning (PBS) proton beams, several dosimetric issues are addressed. The PBS approach may lead to large hot or cold spots in dose distributions delivered to the patients, potentially affecting the tumor control and/or increasing normal tissue side effects. This delivery method particularly benefits image-guided approaches. Our paper aims at reviewing imaging strategies and their technological trends for PBT in thoracic lesions. The focus is on the use of imaging strategies in simulation, planning, positioning, adaptation, monitoring, and delivery of treatment and how changes in the anatomy of thoracic tumors are handled with the available tools and devices in PBT. Starting from bibliographic research over the past 5 years, retrieving 174 papers, major key questions, and implemented solutions were identified and discussed; the results aggregated and presented following the methodology of analysis of expert interviews.

2.
Phys Med ; 88: 226-234, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34311160

RESUMO

PURPOSE: To perform the validation of the GPU-based (Graphical Processing Unit based) proton Monte Carlo (MC) dose engine implemented in a commercial TPS (RayStation 10B) and to report final dose calculation times for clinical cases. MATERIALS AND METHODS: 440 patients treated at the Proton Therapy Center of Trento, Italy, between 2018 and 2019 were selected for this study. 636 approved plans with 3361 beams computed with the clinically implemented CPU-MC dose engine (version 4.2 and 4.5), were used for the validation of the new algorithm. For each beam, the dose was recalculated using the new GPU-MC dose engine with the initial CPU computation settings and compared to the original CPU-MC dose. Beam dose difference distributions were studied to ensure that the two dose distributions were equal within the expected fluctuations of the MC statistical uncertainty (s) of each computation. Plan dose distributions were compared with respect to the dosimetric indices D98, D50 and D1 of all ROIs defined as targets. A complete assessment of the computation time as a function of s and dose grid voxel size was done. RESULTS: The median over all mean beam dose differences between CPU- and GPU-MC was -0.01% and the median of the corresponding standard deviations was close to (√2s) both for simulations with an s of 0.5% and 1.0% per beam. This shows that the two dose distributions can be considered equal. All the DVH indices showed an average difference below 0.04%. About half of the plans were computed with 1.0% statistical uncertainty on a 2 mm dose calculation grid, for which the median computation time was 5.2 s. The median computational speed for all plans in the study was 8.4 million protons/second. CONCLUSION: A validation of a clinical MC algorithm running on GPU was performed on a large pool of patients treated with pencil beam scanning proton therapy. We demonstrated that the differences with the previous CPU-based MC were only due to the intrinsic statistical fluctuations of the MC method, which translated to insignificant differences on plan dose level. The significant increase in dose calculation speed is expected to facilitate new clinical workflows.


Assuntos
Terapia com Prótons , Algoritmos , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador
3.
Phys Med ; 70: 28-38, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31954210

RESUMO

PURPOSE: To present a planning strategy for proton pencil-beam scanning when titanium implants need to be crossed by the beam. METHODS: We addressed three issues: the implementation of a CT calibration curve to assign to titanium the correct stopping power; the effect of artefacts on CT images and their reduction by a dedicated algorithm; the differences in dose computation depending on the dose engine, pencil-beam vs Monte-Carlo algorithms. We performed measurement tests on a simple cylinder phantom and on a real implant. These phantoms were irradiated with three geometries (single spots, uniform mono-energetic layer and uniform box), measuring the exit dose either by radio-chromic film or multi-layer ionization chamber. The procedure was then applied on two patients treated for chordoma. RESULTS: We had to set in the calibration curve a mass density equal to 4.37 g/cm3 to saturated Hounsfield Units, in order to have the correct stopping power assigned to titanium in TPS. CT artefact reduction algorithm allowed a better reconstruction of the shape and size of the implant. Monte-Carlo resulted accurate in computing the dose distribution whereas the pencil-beam algorithm failed due to sharp density interfaces between titanium and the surrounding material. Finally, the treatment plans obtained on two patients showed the impact of the dose engine algorithm, with 10-20% differences between pencil-beam and Monte-Carlo in small regions distally to the titanium screws. CONCLUSION: The described combination of CT calibration, artefacts reduction and Monte-Carlo computation provides a reliable methodology to compute dose in patients with titanium implants.


Assuntos
Cordoma/terapia , Próteses e Implantes , Terapia com Prótons/efeitos adversos , Titânio/química , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Artefatos , Calibragem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Prótons , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos
4.
Phys Med Biol ; 65(4): 045002, 2020 02 10.
Artigo em Inglês | MEDLINE | ID: mdl-31851957

RESUMO

To implement a robust multi-field optimization (MFO) technique compatible with the application of a Monte Carlo (MC) algorithm and to evaluate its robustness. Nine patients (three brain, five head-and-neck, one spine) underwent proton treatment generated by a novel robust MFO technique. A hybrid (hMFO) approach was implemented, planning dose coverage on isotropic PTV compensating for setup errors, whereas range calibration uncertainties are incorporated into PTV robust optimization process. hMFO was compared with single-field optimization (SFO) and full robust multi-field optimization (fMFO), both on the nominal plan and the worst-case scenarios assessed by robustness analysis. The SFO and the fMFO plans were normalized to hMFO on CTV to obtain iso-D95 coverage, and then the organs at risk (OARs) doses were compared. On the same OARs, in the normalized nominal plans the potential impact of variable relative biological effectiveness (RBE) was investigated. hMFO reduces the number of scenarios computed for robust optimization (from twenty-one in fMFO to three), making it practicable with the application of a MC algorithm. After normalizing on D95 CTV coverage, nominal hMFO plans were superior compared to SFO in terms of OARs sparing (p  < 0.01), without significant differences compared to fMFO. The improvement in OAR sparing with hMFO with respect to SFO was preserved in worst-case scenarios (p  < 0.01), confirming that hMFO is as robust as SFO to physical uncertainties, with no significant differences when compared to the worst case scenarios obtained by fMFO. The dose increase on OARs due to variable RBE was comparable to the increase due to physical uncertainties (i.e. 4-5 Gy(RBE)), but without significant differences between these techniques. hMFO allows improving plan quality with respect to SFO, with no significant differences with fMFO and without affecting robustness to setup, range and RBE uncertainties, making clinically feasible the application of MC-based robust optimization.


Assuntos
Terapia com Prótons/métodos , Algoritmos , Humanos , Método de Monte Carlo , Neoplasias/radioterapia , Órgãos em Risco/efeitos da radiação , Terapia com Prótons/efeitos adversos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Eficiência Biológica Relativa , Incerteza
5.
Acta Oncol ; 58(12): 1720-1730, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31393203

RESUMO

Background and purpose: A collaborative network between proton therapy (PT) centres in Trento in Italy, Poland, Austria, Czech Republic and Sweden (IPACS) was founded to implement trials and harmonize PT. This is the first report of IPACS with the aim to show the level of harmonization that can be achieved for proton therapy planning of head and neck (sino-nasal) cancer.Methods: CT-data sets of five patients were included. During several face-to-face and online meetings, a common treatment planning protocol was developed. Each centre used its own treatment planning system (TPS) and planning approach with some restrictions specified in the treatment planning protocol. In addition, volumetric modulated arc therapy (VMAT) photon plans were created.Results: For CTV1, the average Dmedian was 59.3 ± 2.4 Gy(RBE) for protons and 58.8 ± 2.0 Gy(RBE) for VMAT (aim was 56 Gy(RBE)). For CTV2, the average Dmedian was 71.2 ± 1.0 Gy(RBE) for protons and 70.6 ± 0.4 Gy(RBE) for VMAT (aim was 70 Gy(RBE)). The average D2% for the spinal cord was 25.1 ± 8.5 Gy(RBE) for protons and 47.6 ± 1.4 Gy(RBE) for VMAT. The average D2% for chiasm was 46.5 ± 4.4 Gy(RBE) for protons and 50.8 ± 1.4 Gy(RBE) for VMAT, respectively. Robust evaluation was performed and showed the least robust plans for plans with a low number of beams.Discussion: In conclusion, several influences on harmonization were identified: adherence/interpretation to/of the protocol, available technology, experience in treatment planning and use of different beam arrangements. In future, all OARs that should be included in the optimization need to be specified in order to further harmonize treatment planning.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Cooperação Internacional , Órgãos em Risco , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tronco Encefálico/efeitos da radiação , Cóclea/efeitos da radiação , Europa (Continente) , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Laringe/efeitos da radiação , Neoplasias Nasais/diagnóstico por imagem , Neoplasias Nasais/radioterapia , Nervo Óptico/efeitos da radiação , Órgãos em Risco/efeitos da radiação , Neoplasias dos Seios Paranasais/diagnóstico por imagem , Neoplasias dos Seios Paranasais/radioterapia , Glândula Parótida/efeitos da radiação , Fótons/uso terapêutico , Radioterapia de Intensidade Modulada/métodos , Tomografia Computadorizada por Raios X , Carga Tumoral
6.
Med Dosim ; 42(3): 238-246, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28645509

RESUMO

In a radiotherapy center, daily quality assurance (QA) measurements are performed to ensure that the equipment can be safely used for patient treatment on that day. In a pencil beam scanning (PBS) proton therapy center, spot positioning, spot size, range, and dose output are usually verified every day before treatments. We designed, built, and tested a new, reliable, sensitive, and inexpensive phantom, coupled with an array of ionization chambers, for daily QA that reduces the execution times while preserving the reliability of the test. The phantom is provided with 2 pairs of wedges to sample the Bragg peak at different depths to have a transposition on the transverse plane of the depth dose. Three "boxes" are used to check spot positioning and delivered dose. The box thickness helps spread the single spot and to fit a Gaussian profile on a low resolution detector. We tested whether our new QA solution could detect errors larger than our action levels: 1 mm in spot positioning, 2 mm in range, and 10% in spot size. Execution time was also investigated. Our method is able to correctly detect 98% of spots that are actually in tolerance for spot positioning and 99% of spots out of 1 mm tolerance. All range variations greater than the threshold (2 mm) were correctly detected. The analysis performed over 1 month showed a very good repeatability of spot characteristics. The time taken to perform the daily quality assurance is 20 minutes, a half of the execution time of the former multidevice procedure. This "in-house build" phantom substitutes 2 very expensive detectors (a multilayer ionization chamber [MLIC] and a strip chamber, reducing by 5 times the cost of the equipment. We designed, built, and validated a phantom that allows for accurate, sensitive, fast, and inexpensive daily QA procedures in proton therapy with PBS.


Assuntos
Imagens de Fantasmas , Terapia com Prótons , Humanos , Garantia da Qualidade dos Cuidados de Saúde
7.
Radiother Oncol ; 123(1): 112-118, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28283192

RESUMO

BACKGROUND AND PURPOSE: Proton therapy is the emerging treatment modality for craniospinal irradiation (CSI) in pediatric patients. Herein, special methods adopted for CSI at proton Therapy Center of Trento by pencil beam scanning (PBS) are comprehensively described. MATERIALS AND METHODS: Twelve pediatric patients were treated by proton PBS using two/three isocenters. Special methods refer to: (i) patient positioning in supine position on immobilization devices crossed by the beams; (ii) planning field-junctions via the ancillary-beam technique; (iii) achieving lens-sparing by three-beams whole-brain-irradiation; (iv) applying a movable-snout and beam-splitting technique to reduce the lateral penumbra. Patient-specific quality assurance (QA) program was performed using two-dimensional ion chamber array and γ-analysis. Daily kilovoltage alignment was performed. RESULTS: PBS allowed to obtain optimal target coverage (mean D98%>98%) with reduced dose to organs-at-risk. Lens sparing was obtained (mean D1∼730cGyE). Reducing lateral penumbra decreased the dose to the kidneys (mean Dmean<600cGyE). After kilovoltage alignment, potential dose deviations in the upper and lower junctions were small (average 0.8% and 1.2% respectively). Due to imperfect modeling of range shifter, QA showed better agreements between measurements and calculations at depths >4cm (mean γ>95%) than at depths<4cm. CONCLUSIONS: The reported methods allowed to effectively perform proton PBS CSI.


Assuntos
Radiação Cranioespinal/métodos , Posicionamento do Paciente , Terapia com Prótons/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Órgãos em Risco , Garantia da Qualidade dos Cuidados de Saúde , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem
8.
Int J Part Ther ; 4(1): 7-13, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-31773001

RESUMO

We report the case of an 87-year-old man affected by an unresectable ameloblastoma of the right jaw that was successfully treated by definitive proton therapy up to a dose of 66 Gy in 33 fractions. Treatment was well tolerated, and there were no interruptions due to toxicity. At follow-up visits, the patient experienced complete response to treatment with no evidence of disease and complete recovery from acute side effects. In this report, we discuss the potential and possible pitfalls of proton therapy in the treatment of specific settings.

9.
Eur J Nucl Med Mol Imaging ; 32(12): 1392-9, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16133395

RESUMO

PURPOSE: Positron emission tomography is the most advanced scintigraphic imaging technology and can be employed in the planning of radiation therapy (RT). The aim of this study was to evaluate the possible role of fused images (anatomical CT and functional FDG-PET), acquired with a dedicated PET/CT scanner, in delineating gross tumour volume (GTV) and clinical target volume (CTV) in selected patients and thus in facilitating RT planning. METHODS: Twenty-eight patients were examined, 24 with lung cancer (17 non-small cell and seven small cell) and four with non-Hodgkin's lymphoma in the head and neck region. All patients underwent a whole-body PET scan after a CT scan. The CT images provided morphological volumetric information, and in a second step, the corresponding PET images were overlaid to define the effective target volume. The images were exported off-line via an internal network to an RT simulator. RESULTS: Three patient were excluded from the study owing to change in the disease stage subsequent to the PET/CT study. Among the remaining 25 patients, PET significantly altered the GTV or CTV in 11 (44%) . In five of these 11 cases there was a reduction in GTV or CTV, while in six there was an increase in GTV or CTV. CONCLUSION: FDG-PET is a highly sensitive imaging modality that offers better visualisation of local and locoregional tumour extension. This study confirmed that co-registration of CT data and FDG-PET images may lead to significant modifications of RT planning and patient management.


Assuntos
Neoplasias de Cabeça e Pescoço/diagnóstico , Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/radioterapia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração