Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Acta Radiol ; 64(5): 2024-2032, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36451522

RESUMO

BACKGROUND: Redoable precise and non-invasive diagnostic imaging modality with the least radiation dose is essential for infants with congenital heart disease (CHD) . PURPOSE: To investigate the accuracy and estimate the radiation dose of our cardiac computed tomography (CCT) protocol. MATERIAL AND METHODS: A total of 82 infants with CHD underwent non-ECG-gated CCT without contrast timing scanning techniques and were retrospectively studied. The image quality and radiation dose were estimated. The radiation dose was compared statistically to virtual retrospective ECG-gated and prospective ECG-triggering scanning modes. The diagnostic accuracy was assessed assuming the surgical results as the diagnostic gold standard. RESULTS: Most exams showed a high quality with low radiation doses compared to previous studies. The mean effective dose (ED) was 0.39 ± 1.2, significantly lower than that of the virtual retrospective ECG-gated and prospective ECG-triggering scanning and lower than in previous studies. Our CCT protocol has achieved a diagnostic accuracy of 99.52% with a sensitivity of 94.83% and specificity of 99.91%. CONCLUSION: Non-ECG-gated CCT without contrast timing techniques can detect the non-coronary cardiovascular defects of CHD in infants with an ultralow radiation dose and a high diagnostic accuracy.


Assuntos
Cardiopatias Congênitas , Tomografia Computadorizada Multidetectores , Lactente , Humanos , Estudos Retrospectivos , Estudos Prospectivos , Doses de Radiação , Angiografia Coronária/métodos , Tomografia Computadorizada Multidetectores/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Eletrocardiografia , Técnicas de Imagem de Sincronização Cardíaca/métodos
2.
J Saudi Heart Assoc ; 32(2): 186-189, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33154913

RESUMO

BACKGROUND: Stuck mechanical heart valves had a debate about the management plan. There is debate regarding the type, dose, and rate of administration of various thrombolytic agents. We report a case with successful thrombolysis using an ultraslow regimen. CASE SUMMARY: A 43-year-old female with a history of aortic valve (AV) and mitral valve replacement (bi-leaflet metallic valves), and tricuspid valve repair (MINI band) at October 2017. Physical examination showed normal metallic first heart sound and weak metallic second heart sound. Laboratory investigations were normal except low INR, hematocrit, and hemoglobin level (9 gm/L due to iron deficiency anemia). Transthoracic echocardiogram (TTE) and Transoesophageal echocardiogram (TEE) confirmed stuck aortic valve leaflet, with a high mean pressure gradient across prosthetic AV (34 mmHg). The mechanical mitral valve was working well. Fluoroscopy showed stuck one of the AV leaflets in a closed position. The treating physician decided to give her the chance for thrombolytic therapy. This case was treated with ultraslow thrombolytic therapy (Alteplase, 1 mg, every hour) with follow up transthoracic echocardiogram every 24 h to check the pressure gradient on the AV. She was young, asymptomatic, and hemodynamically stable. After 48 h of Alteplase, the stuck leaflet was released. The mean pressure gradient dropped to 16 mmHg. DISCUSSION: Ultraslow thrombolytic regimen advised to be tried in stuck mechanical valves and hemodynamically stable patients.

3.
Eur Heart J Case Rep ; 4(3): 1-6, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33073168

RESUMO

BACKGROUND: Haemolytic anaemia is a complication of paravalvular leak (PVL). The correlation between the size of the leak and the severity of haemolysis is unclear. Small leaks can cause severe haemolysis, whereas significant leaks may cause no haemolysis. CASE SUMMARY: We report the case of a 40-year-old male who underwent mechanical mitral and aortic valve replacement 20 years ago. In the last 3 years, the procedure was repeated three times due to infective endocarditis. He presented with severe shortness of breath. A transoesophageal echocardiogram with three-dimensional surgical view showed that both discs of the mechanical mitral valve opened sufficiently but a severe PVL had occurred at the 9-12 o'clock position. The location of the mitral valve was abnormal, the sewing ring was inserted high at the mid-interatrial septum. The mechanical aortic valve functioned well. Closure of the transcutaneous PVL was accomplished with two percutaneously implanted devices, leaving a small leak in between. After closure, he developed haemolytic anaemia (haemoglobin: 6 g/dL, lactate dehydrogenase: 1896 units/L, reticulocyte count: 4.6%). He then received 16 units of packed red blood cells. He developed acute kidney injury and was started on haemodialysis. We then installed two additional devices to completely close the mild residual leak and another device to resolve the bidirectional transseptal defect. After 2 days, his renal function returned to normal and anaemia improved (haemoglobin: 9.1 g/dL). DISCUSSION: Mild residual paravalvular leak can cause severe haemolytic anaemia that is correctable via percutaneous closure of the leak.

4.
Saudi Med J ; 41(8): 819-827, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32789422

RESUMO

OBJECTIVES: To estimate the pre-hospital delay time among patients diagnosed with acute myocardial infarction and to determine factors associated with pre-hospital delay. METHODS: A cross-sectional study was conducted among 200 patients with myocardial infarction at Madinah Cardiac Center, Al Madinah Al Munawarah, Saudi Arabia between November 2019 and March 2020. Data were collected by direct physician-subject interviews. We used the validated version of the modified response to symptoms questionnaire. Chi-square test, t test, and multivariate analysis were used to examine factors associated with pre-hospital delay. RESULTS: The median pre-hospital delay time was 3.7 hours. Among all the patients, 126 patients (63%) arrived at the hospital later than 2 hours from the onset of symptoms. Factors that were significantly associated with pre-hospital delay included a previous information on acute coronary syndrome (adjusted odds ratio [adj OR]=0.35, 95% confidence interval [CI] 0.1-0.6), history of hypercholesteremia (adj OR=2.3, 95% CI 1.1-4.7), arrived by ambulance (adj OR=0.3, 95% CI 0.1-0.8), and increased pain intensity (adj OR=0.7, 95% CI 0.6-0.9). CONCLUSION: Approximately two-thirds of the patients arrived later than 2 hours from the onset of symptoms. A previous information about acute coronary syndrome, history of hypercholesteremia, arrived by ambulance, and increased pain intensity were associated with pre-hospital delay. The study recognizes the need for educational programs about acute myocardial infarction symptoms and the bene ts of availing an ambulance service.


Assuntos
Serviços Médicos de Emergência/estatística & dados numéricos , Hospitais/estatística & dados numéricos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/terapia , Tempo para o Tratamento/estatística & dados numéricos , Síndrome Coronariana Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Ambulâncias/estatística & dados numéricos , Estudos Transversais , Feminino , Educação em Saúde , Humanos , Hipercolesterolemia , Masculino , Pessoa de Meia-Idade , Dor , Arábia Saudita/epidemiologia , Fatores de Tempo
5.
Saudi Med J ; 40(4): 367-371, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30957130

RESUMO

OBJECTIVES: We studied these predictors at a single cardiac center. Methods: A retrospective cohort study was carried out after obtaining approval from the institutional review board. All patients (age, 0-14 years) who underwent  congenital heart disease (CHD)  surgery from January 2014 to June 2016 were included. Prolonged mechanical ventilation (PMV)  was defined as greater than 72 hours of ventilation. Results: A total of 257 patients were included, among whom 219 (85.2%) were intubated for greater than 72 hours and 38 (14.8%) were intubated for ≥72 hours. Age (29.9 versus 11.95 years), weight (9.6 versus 5.9 kg), cross-clamp time (CCT) (53.6 versus 71.8 min), cardiopulmonary bypass time (CBP) (80.98 versus 124.36 min), length of stay in the pediatric intensive care unit (PICU) (10.4 versus 27.2 days), infection (12.8% versus 42.1%), open sternum (0.9% versus 13.2%), re-intubation (19.2% versus 39.5%), pulmonary hypertension (10.9% versus 31.6%), and impaired heart function (10.1% versus 23.7%) were associated with PMV. In terms of Risk Adjustment in Congenital Heart Surgery (RACHS) classification, only patients with RACHS 4 (18.4%) were associated with the risk for PMV. Conclusions: Age, weight, CBP, CCT, pulmonary hypertension, impaired cardiac function, and sepsis are risk factors for PMV. These factors should be considered when deciding surgery and in providing PICU care.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas/cirurgia , Respiração Artificial/efeitos adversos , Adolescente , Fatores Etários , Peso Corporal , Ponte Cardiopulmonar , Criança , Pré-Escolar , Estudos de Coortes , Feminino , Humanos , Hipertensão Pulmonar , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Tempo de Internação , Masculino , Duração da Cirurgia , Estudos Retrospectivos , Fatores de Risco , Sepse , Fatores de Tempo
7.
Eur Heart J Case Rep ; 3(4): 1-5, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32123789

RESUMO

BACKGROUND: Percutaneous implantation of aortic valve for severe aortic stenosis (AS) in the presence of pedunculated mobile left ventricular outflow tract (LVOT) mass not reported before. In this case report, we address the feasibility of this procedure. CASE SUMMARY: An 80-year-old patient who presented with presyncope, transthoracic echocardiogram (TTE), and transoesophageal echocardiography (TOE) revealed severe calcific AS and LVOT mass measuring 2.1*1.5 cm. The patient was turned down for surgery. It was decided that transcatheter aortic valve implantation (TAVI) be performed because the valve compresses the mass against the proximal part of the interventricular septum. The mass peduncle was 1.4 cm, and it was 4 mm away from the annulus. This meant the valve was needed to be deployed 18 mm below the annulus to cover the mass completely. Gentle manipulation and direct valve deployment without preballoon dilation to decrease the possibility of fragment embolization were necessary. Self-expandable core valve deployed as low as possible, after initial deployment, the distance of LVOT covered by the valve measured by TOE 1.66 cm, the whole mass was covered, then the valve was fully deployed. The patient was extubated in the catheterization room; there was no clinical evidence of embolization. The patient was discharged home after 2 days. A follow-up TTE after 6 months showed a well-functioning valve and the LVOT mass then disappeared. DISCUSSION: Pedunculated LVOT mass should be resected surgically. In high-risk surgical patients, direct TAVI to compress the mass is feasible in experienced canters. The safety issues need more research and more cases to judge. Transoesophageal echocardiography during the procedure is mandatory to guide the valve position.

8.
Telemed J E Health ; 25(4): 326-331, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30192202

RESUMO

BACKGROUND: Every year about three million Muslims visit the Holy City of Makkah in Saudi Arabia to perform the Hajj. Because of the large number of people present during this period, pilgrims can be subjected to many health hazards. An adequate system to minimize these health hazards is needed to support the pilgrims who attend the Hajj. This study justifies the need for developing a large data-based m-Health application to identify the health hazards encountered during the Hajj. MATERIALS AND METHODS: In developing a big data-based m-Health application, this study follows the framework suggested by Hevner. The design of the science framework allows the development of a technological solution (i.e., design artifact) of the problem through a series of actions. The design involves rigorous knowledge of the environmental factors, including knowledge of the construction and evaluation of technological solutions, that are important and relevant to an existing problem. RESULTS: Based on the design science framework, the process of artifact development can be classified into Artifact Design, Artifact Implementation, and Artifact Evaluation. This paper presents the Artifact Design step for the design of the big data-based m-Health application, which has an Environmental Relevance Cycle, a Knowledge-based rigor Cycle, and an Artifice development and design cycle. The big data-based m-Health application is a prototype and must be evaluated using the evaluation-and-feedback loop process until the optimum artifact is completely built and integrated into the system. CONCLUSION: Development of a big data-based m-Health application using a design science framework can support the effective and comprehensive plan of the government of Saudi Arabia for preventing and managing Hajj-related health issues. Our proposed model for developing and designing a big data-based m-Health application could provide direction for developing the most advanced solution for dealing with the Hajj-related health issues in the future.


Assuntos
Big Data , Planejamento em Desastres/organização & administração , Islamismo , Modelos de Riscos Proporcionais , Administração em Saúde Pública/métodos , Telemedicina/organização & administração , Viagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Governo Federal , Feminino , Programas Governamentais , Humanos , Masculino , Pessoa de Meia-Idade , Arábia Saudita
9.
J Saudi Heart Assoc ; 30(3): 268-270, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29989026

RESUMO

The recommended anticoagulation regimen for continuous-flow left ventricular assist device (LVAD) systems is warfarin and aspirin with a targeted international normalized ratio (INR) of 2.0-3.0. Our patient is a 58-year-old male who underwent surgical HeartMate III continuous-flow LVAD implantation 3 months ago outside the country. The patient mistakenly stopped taking warfarin for 1 month prior to presenting to our center for a routine visit. Luckily, the patient was doing very well without any complication despite the fact that his INR was 1.0.

10.
J Saudi Heart Assoc ; 30(3): 271-275, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29989068

RESUMO

To the best of our knowledge, there have not been any reports of total transcatheter approach including stenting of severe coarctation of the aorta (CoA), transcatheter aortic valve replacement (TAVR) for concomitant severe aortic valve stenosis, and percutaneous coronary intervention (PCI) to treat significant coronary artery disease in a single patient. We report a 70-year-old female, who presented with uncontrolled hypertension and acute decompensated heart failure (ADHF) and was found to have severe CoA, severe bicuspid aortic valve (BAV) stenosis, and significant proximal left anterior descending (LAD) coronary artery disease. In a multidisciplinary heart team meeting, we decided to perform an endovascular repair of both cardiac and vascular pathologies using a two-stage approach due to the significant comorbidities; mainly uncontrolled hypertension, type 2 diabetes mellitus, chronic obstructive pulmonary disease, and severe calcifications of the ascending aorta. The procedures were successfully performed and the patient was asymptomatic 30 months later at follow-up and was without any significant gradients across the coarctation or the aortic valve.

11.
Ann Saudi Med ; 38(3): 167-173, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29848933

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been recognized as a valid alternative to surgery for severe aortic valve stenosis (AS) in high-risk surgical patients. OBJECTIVE: Determine first-year clinical outcomes for TAVI at Madinah Cardiac Center (MMC) in Saudi Arabia. DESIGN: Retrospective, analytical cross-sectional. SETTING: Tertiary cardiac care center. PATIENTS AND METHODS: All patients who underwent TAVI for severe AS between February 2013 and December 2016 were included. Clinical, imaging, and laboratory information at baseline and at one year follow-up were analyzed. MAIN OUTCOME MEASURES: Clinical and echocardiography out.comes at discharge, at 1-month, and at end of follow-up; one-year mortality, complications and clinical response to TAVI procedure. SAMPLE SIZE AND CHARACTERISTICS: N=80, mean (SD) age 79.5 (10.6) years, with severe AS and high-surgical risk. RESULTS: Fifty-five (69.2%) patients received Core valves, and 25 (30.8%) received Edward valves. Peri-procedure mortality was 3.8% and 1-year post-operative mortality was 13.8%. Ten patients (12.5%) had life-threatening or major bleeding. Nineteen (23.8%) patients had vascular complications, which were mostly minor. Fourteen patients (17.5%) developed acute kidney injury and 86% of these patients recovered. Five patients (6.25%) had pericardial effusion. Two patients (2.5%) developed endocarditis and another 2 patients (2.5%) had cerebrovascular accidents. Five patients (6.25%) received pacemakers. Mean aortic valve gradient significantly reduced from a mean (SD) 47.6 (19) mm Hg to 10.7 (6.0) mm Hg (P less than .001). New York Heart Association functional class was significantly reduced (P less than .001). CONCLUSION: The TAVI experience at MCC is encouraging and comparable to international outcomes in terms of success, morbidity, and mortality rate. LIMITATIONS: Retrospective, relatively small sample size. Rate of minor bleeding was overestimated. CONFLICT OF INTEREST: None.


Assuntos
Estenose da Valva Aórtica/cirurgia , Ecocardiografia , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Estudos Retrospectivos , Arábia Saudita , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...