Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 34(2): 271-276, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31004273

RESUMO

Major hemodynamic changes are frequently noted during liver transplantation (LT). We evaluated the performance of electrical velocimetry (EV) as compared to that of TEE in SV optimization during liver transplantation. This was an observational study in 32 patients undergoing LT. We compared SV values measured simultaneously by EV (SVEV) and TEE (SVTEE) at baseline 30 min after induction, at the end of dissection phase, 30 min after anhepatic phase, 30 min after reperfusion. We also evaluated the reliability of EV to track changes In SV before and after 49 fluid challenges. Finally, the SV variation (SVV) and pulse pressure variation (PPV) were tested as predictors for volume responsiveness, defined as an increase in SV ≥ 10% after 250 ml of colloid. For 112 paired SV data, the overall correlation was 0.76 and bias (limits of agreement) 0.3 (- 29 to 29) ml percentage error 62%. The EV was able to track changes in SV with a concordance rate of 97%, and a sensitivity and specificity of 93% to detect a positive fluid challenge. The AUC values (with 95% confidence intervals) for SVV and PPV were 0.68 (0.52-0.83) and 0.72 (0.57-0.86), respectively, indicating low predictive capacity in these setting. The absolute values of SV derived from EV did not agree with SV derived from TEE. However, EV was able to track the direction of changes in SV during hemodynamic management of patients undergoing liver transplantation.Clinical trial registration: Clinicaltrials.gov Identifier: NCT03228329 prospectively Registered on 13-July-2017.


Assuntos
Monitorização Hemodinâmica/métodos , Transplante de Fígado , Monitorização Intraoperatória/métodos , Ressuscitação , Reologia/métodos , Adulto , Cardiografia de Impedância/métodos , Cardiografia de Impedância/estatística & dados numéricos , Ecocardiografia Transesofagiana , Feminino , Hidratação , Monitorização Hemodinâmica/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/estatística & dados numéricos , Estudos Prospectivos , Reologia/estatística & dados numéricos , Volume Sistólico
2.
Clin Chem Lab Med ; 54(5): 889-95, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26501164

RESUMO

BACKGROUND: Ventilator-associated pneumonia (VAP) is one of the most common nosocomial infections; however, its diagnosis remains difficult to establish in the critical care setting. We investigated the potential role of neutrophil CD64 (nCD64) expression as an early marker for the diagnosis of VAP. METHODS: Forty-nine consecutive patients with clinically suspected VAP were prospectively included in a single-center study. The levels of nCD64, C-reactive protein (CRP), and serum procalcitonin (PCT) were analyzed for diagnostic evaluation at the time of intubation (baseline), at day 0 (time of diagnosis), and at day 3. The receiver operating characteristic curves were analyzed to identify the ideal cutoff values. RESULTS: VAP was confirmed in 36 of 49 cases. In patients with and without VAP, the median levels (interquartile range, IQR) of nCD64 did not differ either at baseline [2.4 (IQR, 1.8-3.1) and 2.6 (IQR, 2.3-3.2), respectively; p=0.3] or at day 0 [2 (IQR, 2.5-3.0) and 2.6 (IQR, 2.4-2.9), respectively; p=0.8]. CRP showed the largest area under the curve (AUC) at day 3. The optimum cutoff value for CRP according to the maximum Youden index was 133 mg/dL. This cutoff value had 69% sensitivity and 76% specificity for predicting VAP; the AUC was 0.73 (95% CI, 0.59-0.85). The nCD64 and PCT values could not discriminate between the VAP and non-VAP groups either at day 0 or day 3. CONCLUSIONS: The results of this pilot study suggest that neutrophil CD64 measurement has a poor role in facilitating the diagnosis of VAP and thus may not be practically recommended to guide the administration of antibiotics when VAP is suspected.


Assuntos
Proteína C-Reativa/análise , Calcitonina/análise , Pneumonia Associada à Ventilação Mecânica/sangue , Pneumonia Associada à Ventilação Mecânica/diagnóstico , Receptores de IgG/sangue , Ferimentos e Lesões/complicações , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neutrófilos/metabolismo , Projetos Piloto , Pneumonia Associada à Ventilação Mecânica/complicações , Estudos Prospectivos , Receptores de IgG/metabolismo , Ferimentos e Lesões/sangue , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...