Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Catheter Cardiovasc Interv ; 96(4): 940-946, 2020 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31797524

RESUMO

OBJECTIVES: We aimed to evaluate early clinical and procedural outcomes with the 34-mm Evolut R transcatheter aortic valve replacement (TAVR) prosthesis. BACKGROUND: The 34-mm Evolut R (Medtronic, Minneapolis, MN) self-expanding TAVR prosthesis was designed to treat patients with larger annuli. METHODS: Clinical, demographic, procedural, and echocardiographic data on consecutive patients who underwent TAVR with a 34-mm Evolut R prosthesis at our institution were collected and analyzed. RESULTS: One hundred ninety-six patients underwent TAVR with this prosthesis from November 2016 to July 2018, a majority (n = 188, 96%) through transfemoral access and with conscious sedation (n = 182, 93%). Mean age, Society of Thoracic Surgery risk score, and follow-up were 82 ± 8 years, 5.4 ± 5%, and 8.2 ± 5.3 months, respectively. Mean aortic valve (AV) peak velocity was 4.0 ± 0.6 m/s, mean AV gradient was 38 ± 13 mmHg, AV area was 0.79 ± 0.23 cm2 ; calcium score was 3,503 ± 1,970 Agatston units, and perimeter was 85 ± 4.3 mm. Device implantation was successful in all but one patient. Postprocedure mean AV peak velocity, AV mean gradient, and AV area were 1.9 ± 0.4 m/s, 7 ± 3 mmHg, and 2.6 ± 0.7 cm2 , respectively. New pacemaker requirement rate was 16%, and moderate paravalvular leak was present in six patients (3%), which improved to mild in three patients at 6-month follow-up. In-hospital, 30-day, 6-month, and 12-month survival rates were 98%, 96% (hospital discharge), 96% (30-day), 89% (6-month), and 83% (12-month). CONCLUSION: These data demonstrate high success and good procedural, echocardiographic, and clinical outcomes of 34-mm Evolut R in patients with large annuli.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/terapia , Desenho de Prótese , Recuperação de Função Fisiológica , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...