Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 22(4)2022 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-35214235

RESUMO

Fetal acidosis is one of the main concerns during labor. Currently, fetal blood sampling (FBS) has become the most accurate measurement of acidosis detection. However, it is invasive and does not provide a real time measurement due to laboratory procedures. Delays in diagnosis of acidosis have caused serious injury to the fetus, especially for the brain and the heart. This paper reviews the new technique in diagnosis of acidosis non-invasively. Magnetic Induction Spectroscopy (MIS) has been proposed to be a new device for acidosis detection in recent years. This paper explains the basic principle of MIS and outlines the design specifications and design considerations for a MIS pH probe. It is expected that readers will gain a basic understanding of the development of a MIS pH probe from this review.


Assuntos
Acidose , Sangue Fetal , Acidose/diagnóstico , Feminino , Sangue Fetal/química , Frequência Cardíaca Fetal , Humanos , Concentração de Íons de Hidrogênio , Fenômenos Magnéticos , Gravidez , Couro Cabeludo , Análise Espectral
2.
Artigo em Inglês | MEDLINE | ID: mdl-24111401

RESUMO

Pedicle Screw (PS) was originally accomplished for Spinal fixation but it has several limitations. If the pedicle screw passes though the cortex bone in surgery, it has a risk to damage the spinal cord and vertebral artery, which can be caused to a serious problem such as paralysis. Therefore, it should be avoided by all possible means. In current situation, it depends on a palpation of doctor to judge the boundary between the cortex and cancellous bone. Although many instrumentation has been described in several clinical studies, there are still lack of data in the literature concerning the measurement of bone thickness in real time mode. Most of the measurements of the bone thicknesses were based on CT Scan machine which is off-line technique. Therefore, the purpose of this prospective study was to develop a real time measurement of bone thickness for safety purpose of pedicle screw insertion. A total of 12 data was collected in each experiment. Ultrasound echo signal for each specimen was measured and used to measured bone thickness. Then, the results were compared with manual measurement of bone thickness which is by using a ruler. The percentage different of bone thickness was small for both methods which were 8.86% for first method and 15.1% for second method. This measurement values showed that the accuracy of bone thickness more than 84% for both method. As a conclusion, both methods were suitable to use as a bone thickness measurement technique for pedicle screw insertion application.


Assuntos
Vértebras Cervicais/anatomia & histologia , Parafusos Pediculares , Vértebras Cervicais/diagnóstico por imagem , Fluoroscopia , Humanos , Doenças da Coluna Vertebral/diagnóstico por imagem , Fusão Vertebral , Tomografia Computadorizada por Raios X , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...