Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Plant Sci ; 321: 111313, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35696913

RESUMO

The growth and composition of fleshy fruits depend on resource acquisition and distribution in the plant. In tomato, the pedicel serves as the final connection between plant and fruit. However, very few quantitative data are available for the conducting tissues of the pedicel, nor is their genetic variability known. In the present study, a histological approach was combined with process-based modeling to evaluate the potential contribution made by the anatomy and histology of the pedicel to variations in fruit mass. Eleven genotypes were characterized and the impact of water deficit was studied for a single genotype using stress intensity and stage of application as variables. The results highlighted extensive variations in the relative proportions of the different pedicel tissues and in the absolute areas of xylem and phloem between genotypes. The model suggests that the variations in the area of the pedicel's vascular tissues induced by differences in genotype and water-deficit environments partly contributed to fruit mass variability. They therefore warrant phenotyping for use in the development of plant strains adapted to future environmental constraints. The results also demonstrated the need to develop non-invasive in vivo measurement methods to establish the number and size of active vessels and the flow rates in these vessels to improve prediction of water fluxes in plant architecture.


Assuntos
Solanum lycopersicum , Frutas/genética , Genótipo , Solanum lycopersicum/genética , Água , Xilema
2.
Magn Reson Chem ; 57(9): 749-756, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31240742

RESUMO

Today, in the presence of global warming, understanding how plants respond to drought stress is essential to meet the challenge of developing new cultivars and new irrigation strategies, consistent with the maintenance of crop productivity. In this context, the study of the relation between plants and water is of central interest for modeling their responses to biotic and abiotic constraints. Paradoxically, there are very few direct and noninvasive methods to quantify and measure the level and the flow of water in plants. The present work aims to develop a noninvasive methodology for living plant based on nuclear magnetic resonance (NMR) at low magnetic field and imaging (MRI) to tackle the issue of water quantity in plants. For this purpose, a portable NMR device measuring the signal level at 8 mT was built. This instrument addresses specific challenges such as miniaturization, accessibility, and overheating in order to maintain the plant intact of time over long period. Time dependence of the water content in sorghum plants is reported under abiotic stress as well as the fraction of transpirable soil water and the photosynthesis activity through the leaves. At high magnetic field (9.4 T), T2 maps were acquired on the same sorghum plants at two time points. The combination of these approaches allows us to identify ecophysiological biomarkers of drought stress. One particular interesting result concerns the spatial distribution of water in two anatomically contrasted sorghum genotypes.

3.
PLoS One ; 13(3): e0194845, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29596455

RESUMO

The climate warming implies an increase of stress of plants (drought and torrential rainfall). The understanding of plant behavior, in this context, takes a major importance and sap flow measurement in plants remains a key issue for plant understanding. Magnetic Resonance Imaging (MRI) which is well known to be a powerful tool to access water quantity can be used to measure moving water. We describe a novel flow-MRI method which takes advantage of inflow slice sensitivity. The method involves the slice selectivity in the context of multi slice spin echo sequence. Two sequences such as a given slice is consecutively inflow and outflow sensitive are performed, offering the possiblility to perform slow flow sensitive imaging in a quite straigthforward way. The method potential is demonstrated by imaging both a slow flow measurement on a test bench (as low as 10 µm.s-1) and the Poiseuille's profile of xylemian sap flow velocity in the xylematic tissues of a tomato plant stem.


Assuntos
Imageamento por Ressonância Magnética , Solanum lycopersicum/metabolismo , Mudança Climática , Solanum lycopersicum/fisiologia , Estresse Fisiológico , Água/metabolismo
4.
Front Aging Neurosci ; 9: 230, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28769787

RESUMO

Central nervous system (CNS) injury has been observed to lead to microglia activation and monocytes infiltration at the lesion site. Ex vivo diffusion magnetic resonance imaging (diffusion MRI or DWI) allows detailed examination of CNS tissues, and recent advances in clearing procedures allow detailed imaging of fluorescent-labeled cells at high resolution. No study has yet combined ex vivo diffusion MRI and clearing procedures to establish a possible link between microglia/monocytes response and diffusion coefficient in the context of spinal cord injury (SCI). We carried out ex vivo MRI of the spinal cord at different time-points after spinal cord transection followed by tetrahydrofuran based clearing and examined the density and morphology of microglia/monocytes using two-photon microscopy. Quantitative analysis revealed an early marked increase in microglial/monocytes density that is associated with an increase in the extension of the lesion measured using diffusion MRI. Morphological examination of microglia/monocytes somata at the lesion site revealed a significant increase in their surface area and volume as early as 72 hours post-injury. Time-course analysis showed differential microglial/monocytes response rostral and caudal to the lesion site. Microglia/monocytes showed a decrease in reactivity over time caudal to the lesion site, but an increase was observed rostrally. Direct comparison of microglia/monocytes morphology, obtained through multiphoton, and the longitudinal apparent diffusion coefficient (ADC), measured with diffusion MRI, highlighted that axonal integrity does not correlate with the density of microglia/monocytes or their somata morphology. We emphasize that differential microglial/monocytes reactivity rostral and caudal to the lesion site may thus coincide, at least partially, with reported temporal differences in debris clearance. Our study demonstrates that the combination of ex vivo diffusion MRI and two-photon microscopy may be used to follow structural tissue alteration. Lesion extension coincides with microglia/monocytes density; however, a direct relationship between ADC and microglia/monocytes density and morphology was not observed. We highlighted a differential rostro-caudal microglia/monocytes reactivity that may correspond to a temporal difference in debris clearance and axonal integrity. Thus, potential therapeutic strategies targeting microglia/monocytes after SCI may need to be adjusted not only with the time after injury but also relative to the location to the lesion site.

5.
PLoS One ; 11(1): e0144483, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26751800

RESUMO

Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to characterize and model evanescent electromagnetic fields originating from NMR phenomenon. We report that in this experimental configuration the available NMR signal is one order of magnitude larger and follows an exponential decay inversely proportional to the size of the emitters. Those investigations open a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging.


Assuntos
Espectroscopia de Ressonância Magnética/métodos , Capacitância Elétrica , Eletrodos , Campos Eletromagnéticos , Espectroscopia de Ressonância Magnética/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...